Loading...
SR 02-14-2017 7A Ci ty Council Report C ity Council Meeting : February 14, 2017 Agenda Item: 7.A 1 of 14 To: Mayor and City Council From: David Martin, Director , Building & Safety Subject: Resolution Making Findings of Local Climatic, Geological and Topographical Conditions and Introduce for First Reading an Ordinance Updating Seismic Retrofit Requirements for Potentially Seismically Vulnerable Buildings, Updating Tenant Protection Laws and Implementing a Seismic Retrofit Program Recommended Action Staff recommends that the City Council: 1. Adopt the resolution making findings of local climatic, geological an d topographical conditions necessary to support the adoption of local amendments to the California State Building Codes; 2. Introduce for first reading the ordinance, amending the California State Building Codes to adopt updates to seismic retrofit requireme nts a nd adopting enhancements to lo cal tenant protection laws; and 3. Instruct staff to file the adopted resolution and seismic retrofit ordinance with the California Building Standards Commission following the second reading of the ordinance but at least 30 days before the effective date of the ordinance. Executive Summary A fundamental expectation in the occupancy of residential and commercial structures is that buildings are safe and free from hazard. Buildings that provide resistance to the destructive forces of earthquakes and aftershocks are an essential component in building safety and occupancy. Strengthening of older less resistant buildings is necessary in order to provide the structural resiliency to increase occupant safety. An update to the Ci ty’s existing seismic retrofit standards and implementing retrofit requirements for potentially vulnerable buildings would provide increased measures of occupant safety. The proposed ordinance, Attachment A, provides updates of the seismic retrofit requir ements adopted by the City Council on June 8, 1999. Both California state laws regulating Building Code adoption and California Health and Safety Code Sections 19101 and 19162 -63.6 authorize local jurisdictions to establish mandatory seismic retrofit st andards. Pursuant to Section 18941.5 of the California 2 of 14 Health and Safety Code , amendments to the California Building Standards Code are required to be justified by local climatic, geological and topographical conditions. The attached Resolution with prop osed local findings is provided in Attachment B. Staff has identified buildings that may be potentially seismically vulnerable and has represented these buildings in an inventory (List) provided as Attachment C. The Seismic Retrofit Program (Program) wil l target these identified unretrofitted buildings where Program compliance and enforcement will be required in conformance with the schedule outlined in the ordinance. Retrofitting seismically vulnerable buildings is proposed through an active and ongoin g Seismic Retrofit Program. The Program will includ e identification, notification, compliance procedures, and residential tenant protections. In addition, timely processing and compliance will also require consultant services to provide structural plan c heck and peer review of complex structural retrofit designs. Should Council adopt the Resolution and Ordinance, staff will initiate a Request f or Proposal for the procurement of engineering consultant services to address processing of seismic retrofit pla ns and to maintain expected service levels in construction permitting . The proposed ordinance also seeks revisions to Chapter 8.100 Tenant Protection During Construction and Chapter 4.36 Tenant Relocation Assistance. Revisions to these Chapters will enha nce existing tenant protections and incorporate measure s for hazardous material cases. A proposed revision includes addressing issues related to hazardous materials found in older construction materials. Additional proposed revisions will also require bu ilding owners to pay for environmental consulting services in the determination and resolution of hazardous materials. To address this issue, staff is recommending the issuance of a Request for Proposal for the procurement of environmental consultant serv ices. Since construction work has the potential to impact existing residential tenants, passage of the seismic retrofit ordinance and the resulting construction has the potential to create impacts to existing tenants. The implementation of the Program w ill include means for tenant advocacy and advisory. All affected City Departments will engage in the support of residential tenants and the response to retrofit compliances. 3 of 14 Background On December 6, 2016, City Council conducted a Study Session on the d egree of seismically vulnerable buildings 1 in Santa Monica that are subject to damage or collapse in a seismic event. The Staff Report of the Study Session, provided herein as Attachment D, provided the total number of unretrofitted buildings that were id entified as potentially seismically vulnerable. Council was presented with recommendations for updates to the City’s 1999 retrofit standards and recommendations for a fully active Seismic Retrofit Program. City Council instructed staff to proceed with th e development of an ordinance that provides updates to the standards for seismic retrofit and implement ation of a Seismic Retrofit Program. The proposed ordinance also includes compliance timeframes, notification procedures, and measures for increased ten ant protections. Council instructed staff to research previous Federal and State grant funding related to seismic retrofit and if such grants are still available. ______________________________________________________________________ 1 The cate gories of Seismically Vulnerable Buildings and existing Santa Monica Municipal Code Chapters are as follows:  Unreinforced Masonry Bearing Wall Buildings (Chapter 8.60)  Reinforced Concrete or Masonry Wall Buildings with Flexible Diaphragms (Chapter 8.64)  Si ngle -Family Dwellings, Strengthening of Cripple Walls and Sill Plate Anchorage (Chapter 8.68)  Soft, Weak, or Open Front Wall in Wood -Framed Buildings (Chapter 8.72)  Welded Steel Moment Frame Buildings (Chapter 8.76)  Non -Ductile Concrete Buildings (Chapter 8.80) ____________________________________________________________________________________ 4 of 14 Discussion Retrofitting, or the strengthening of the structural system of older seismically vulnerable buildings increases the lateral load resisting system in these older buildings allowing better performance in earthquakes and aftershocks. Better performance will significantly reduce the potential for building damage and collapse, lessening the occurrences of occupant injury or death. The updates to the technical standards for seismic retrofit in the proposed ordinance are recommended to improve performance of buildings to levels similar to minimum life - safety levels of the State building code. Although minimum life -safety levels of seismic retrofit does not elimi nate the possibility of injury or death due to building damage, the proposed standards would result in substantial gains in protecting the City’s inhabitants, workers and visitors. Seismic Retrofit Program Implementation List – Potentially Seismically Vuln erable Buildings At the December 6, 2016 Study Session, staff presented to Council that the identification and inventory (List) of potentially seismically vulnerable buildings will be available in January 2017. The List was made publically available on Ja nuary 26, 2017 on a City webpage dedicated to the Seismic Retrofit Program. As indicated on the List, all types of seismically vulnerable buildings will be targeted for notification, structural analysis and if found to be deficient, the requirement to com plete retrofit of the building. The List is an inventory of buildings that may require retrofit based on determination through building permit records and visual identification. In addition, the List will be dynamic as a structural analysis of some build ings may find that a building does not require retrofit in which case the building would be removed from the list. Likewise, buildings not currently on the List may someday be identified as requiring retrofit when structural systems are revealed during te nant modifications to the buildings. The List will serve as a basis in the milestone steps towards retrofit compliance with iterative steps noted once completed. 5 of 14 Notification, Time Limits and Recordation of Properties Owners of buildings on the List wi ll be notified that their building has been identified as potentially seismically vulnerable. Once notified , a building owner will be required to provide a structural analysis of the building and a recommendation for a retrofit solution, if necessary. Th e notification will serve as the official commencement of the time period in which the building owner has to comply with milestones of compliance. The proposed ordinance identifies priorities of hazardous building types in which notification will be phase d by order of hazard severity, compliance timeframe and building type. The phasing of the notices will allow for the segmenting of 4,594 notices to building owners. The overall compliance time limit is provided per bu ilding type in the table below. Poten tially Seismically V ulnerable Buildings Type Years to Complete Retrofit Unreinforced Masonry Buildings 2 Years Concrete Tilt -Up Buildings 3 Years Soft -Story Buildings 6 Years Non -Ductile Concrete Buildings 10 Years Steel Moment Frame Buildings 20 Year s Single -Family Brace and Bolts Voluntary 6 of 14 In the case of multiple ownership of a building where a building consists of multiple parcels such as condominiums, each owner of a parcel will receive a notice. The List identifies condominium buil dings by legal address with individual parcels. The proposed ordinance includes major milestones in the process of seismic retrofitting of a building. The milestones include interim deadlines that will allow for compliance monitoring. Consultation by staff will be available to advise the small family -owned residential owners and small business/building owners with information necessary for understanding the steps of compliance in the retrofit process. At the December 6, 2016 Study Session, Council dire cted staff to examine the effects of a recorded notice on the title of a property. Staff explored if a recording will introduce constraints from lending institutions on property loans and discovered that there will be no significant effect. Staff is r eco mmend ing that the proposal for a recorded notice will be a positive factor in the achievement of retrofit compliance as well as fair disclosure to parties involved in the affected properties. Staff will propose general language on the notice to be recorde d with the County of Los Angeles Office of the Registrar/Recorder as to not overburden impact on title transfers and the securing of loans including loans for the financing of seismic retrofit. Both the City of Los Angeles and the City and County of San F rancisco have included recordation of seismic retrofit requirements in their process. Consultant Services Buildings with complex structural systems, such as the Steel Moment Frame and Non -Ductile Concrete buildings will have detailed complicated retrofit solutions. Complex retrofit designs will require peer review which is a standard practice in structural design of complicated buildings. Peer review is the process where an independent structural engineer reviews the design of a retrofit plan and provide s input to best practices in the structural design of a project. Peer review is a detailed highly -technical exercise involving specialized expertise that should be handled by consultant services. Therefore, staff recommend s incorporating the 7 of 14 procedure of peer review as a necessary part of seismic retrofit. Costs for peer review will be proposed and presented to the City Council as part of the FY 2017 - 19 biennial budget. In addition to peer review, the volume of plans anticipated for seismic retrofit will require consulting services for the plan check of seismic retrofit designs. The consulting services will augment Building and Safety staff, as -needed, for the plan review of large complex buildings and for peak submittals of plans. Funding for consu ltant plan check will be incorporated with the FY 2017 -19 biennial City budget. It is recommended that City Council authorize staff to issue a Request for Proposal s for consultant services for seismic retrofit plan check and peer review. Parking Effects The structural strengthening of a building related to seismic retrofit may have an effect on parking spaces by reducing the dimensions of a required parking space or in some cases eliminating required parking. Where the retrofit solution provides that the re is no alternate practical solutions to a retrofit, the proposed ordinance provides that the Zoning Administrator may reduce the required size of a parking space or the number of required spaces. The proposal is that parking shall not be reduced more th an twenty -percent (20%) of required parking spaces or one (1 ) space, whichever is greater. Tenant Protection Protection of tenants and the stock of affordable housing in the City are of paramount importance. Construction in residential buildings, if not conducted or monitored with diligence could be of significant impact to tenants. The proposed ordinance provides for several amendments to strengthen tenant protections for standard ongoing construction projects, and for construction related to the Seismi c Retrofit Program. Added requirements and revisions to Chapters 8.100 and 4.36 are presented as part of the proposed ordinance. 8 of 14 Enhancements to Tenant Protection During Construction, Chapter 8.100 The following proposed revisions to Chapter 8.100 are pur posed to enhance protection of tenants during construction activity.  Older buildings are likely to contain building materials of hazardous content and if disturbed, can be of detrimental effect to humans and possibly pets. Materials such as asbestos and l ead paint may still be present in some of the buildings that require seismic retrofit. Existing State Law procedures require a building owner to abate hazardous materials in accordance with procedures of the Southern California Air Quality Management Dist rict (AQMD). Proper adherence to these procedures should provide tenants with the assurance that hazardous materials are abated and no longer pose a health threat. Staff proposes to add additional requirements to Chapter 8.100 to: (1) clarify that owners must ensure that all hazardous materials are properly handled during construction; (2) the City will actively monitor such handling; and (3) the City may reasonable engage the services of qualified experts, at the owner’s expense, to assist the City in evaluating the owner’s compliance.  Relatedly, staff also request that the City Council instruct staff to initiate a Request for Proposal s to procure the services of licensed environmental consultants as advisors to the City on issues of hazardous materials .  Section 8.100.040(c)(9) requires a building owner to provide monthly notices to tenants on construction progress for projects that exceed thirty - days of construction. This section also allows the Building Officer to request meetings to allow tenant feed back to construction issues. Proposed with this ordinance is clarifying that the request of the Building Officer is not appealable given the timeliness of a requested meeting and tenant concerns. Enhancements to Tenant Relocation Assistance, Chapter 4.36 The following clarifications and enhancements are proposed to Chapter 4.36 to address improvements and revisions in tenant relocation. 9 of 14  For short -term tenant displacements (e.g. due to inoperable equipment such as hot water heating or environmental heat ) a proposal to allow owners to relocate tenants to a hotel is presented in the ordinance. The relocation to a hotel would be an option instead of paying the daily per diem, or providing comparable housing if relocation is estimated to be five days or less. Tenants would be entitled to per diem payments or be relocated to comparable accommodations if relocation extends beyond five days. Staff is proposing five days as a measure for timely relocations as staff determined that the majority of relocations are typically at five days or less.  Existing law does not require owners to expeditiously repair tenant units while tenants are relocated. In some relocation cases, the extent of a tenant being relocated was not proportionate to the estimated time to addres s the condition causing the relocation. A proposal to require a maximum time limit in which a tenant is relocated is included in the ordinance. The estimated maximum time frame will be based on the condition causing relocation as determined by the Buildi ng Officer. Should the estimated time limit be exceeded, an investigation will be warranted to determine causes for the delay. Where relocation is in excess of the estimated time limit without reasonable cause, the Code Enforcement Division would initiat e enforcement action.  As timely resolution is desired in a relocation case to remedy conditions of uninhabitability, added language to Chapter 4.36 is proposed to ensure that the owner has access to the rental unit and have the opportunity to timely addres s the condition without interference from the tenant. This is proposed to address recent issues where building owners were prevented by a tenant from making necessary repairs causing relocations to be prolonged. Staff asserts that this allowance will prov ide for timely resolutions.  Sections 4.36.120(c) and (d) currently do not allow relocation benefits when a tenant is displaced as a result of seismic retrofit. Research 10 of 14 determined that this language was written in the 1999 seismic retrofit ordinance. It was included in hopes of incentivizing owners to commence retrofitting; however, experience has shown that this incentive is ineffective and that it unnecessarily burdens tenants. Staff proposes that this Section be repealed to meet current relocation goa ls of the City. Eliminating this provision will likely also encourage more timely completion of seismic retrofit projects. Exemptions to Zonal Restrictions on Construction Due to the mandated timeline contained in the seismic retrofit ordinance, it is po ssible that seismic retrofit of several multi -family buildings may occur simultaneously. However, local law (namely the Construction Rate Program of Chapter 9.37.110) only allows one project (involving the new construction or alteration of 2 or more dwell ing units in the R2, R3, R4, OF, RMH, OPD, OP2, OP3, and OP4 Districts) to occur within a 500 -foot radius at a time. This restriction could have a negative impact on the retrofit compliance efforts of multi - family buildings. Although Section 9.37.110 con tains an exemption for seismic retrofit projects, that exemption only applies to unreinforced masonry type buildings. The proposed ordinance seeks to override this prohibition and allow all seismic retrofit projects to proceed simultaneously. Tenant and Occupant Advisory The proposed ordinance includes a requirement that building owners must notify each residential and commercial tenant when the Building Officer determines that a building is seismically vulnerable and subject to retrofit to comply with lo cal law. This notice is an advisory to tenants and will include references to contacts in the City for assistance. As part of milestone compliance, the building owner is required to provide the Department with evidence that each tenant has been provided with the tenant advisory related to seismic retrofit. For buildings that will require retrofit construction, Chapter 8.100 currently requires posting of Construction Notification (on a 30 -inch by 40 -inch poster) that states effects during the construction and interruptions to building services. 11 of 14 Public Assistance, Public Information Staff will be available for general and detailed questions for each aspect of compliance with the Program. To assist with general information, a webpage dedicated to the Se ismic Retrofit Program in already available on the City’s website. Webpage On January 26, 2017, the Department launched the Seismic Retrofit Program webpage which includes the List of potentially seismically vulnerable buildings. Should Council adopt the ordinance, the webpage will be updated with program information for owners and tenants. Other information planned for the webpage will include financing information for loan assistance for seismic retrofit. This will include the seven private financier s listed on the Resolution that City Council approved on February 23, 2016 as indicated in the Study Session report. Planned with Council’s passage of the ordinance is a Seismic Retrofit Fair where building owners, residential and commercial tenants and b usiness merchants may obtain information about the Seismic Retrofit Program in a “one stop” event. In addition to City staff, financiers, product vendors, consulting architects and engineers, and building contractors who specialize in seismic retrofit wil l have a presence at the Fair. The webpage will provide event dates, and information related to the Seismic Retrofit Fair. Staffing A major component in achieving compliance of the Seismic Retrofit Program is the timely completion of a building retrofit. A key factor in timely compliance is staff’s ability to process applications, structural reports, seismic design plans and the issuance of building permits. Three additional positions will provide the needed resources to address additional workload such as resident and owner services, application - notification -recordation processing, structural engineering analysis and customer 12 of 14 guidance. The positions will be covered with new revenues and presented as part of the FY 2017 -19 biennial budget process. Cos t and Financing of Retrofit The Study Session Staff Report contained approximate costs for seismic retrofit. Staff reported at the Study Session that State Assembly Bill 837 set up the California Seismic Safety Capital Access Loan Program Fund for residen ces and small businesses related to seismic retrofit. This Bill is now codified as California Health a nd Safety Code 44559.14 and provides another source of financing for seismic retrofit. At the December 6, 2016 Study Session, Council asked if previous s eismic retrofit funding after the 1994 Northridge Earthquake from the Federal and State governments granted to building owners in Santa Monica might still be available. Research found that many buildings were retrofitted utilizing grant monies, however, t he funds are no longer available. Rent Control Board Hearing Should City Council adopt the proposed ordinance, following the second reading of the ordinance, the Rent Control Board will be presented with a request to determine the extent of pass -through c osts of retrofit work to tenants. The Rent Control Board will be asked to determine if pass -through costs should be included as part of monthly tenant rents, and if so, the percentage of retrofit cost attributed to the pass -through, the total term and the maximum monthly pass -through costs. CEQA Exemption The proposed ordinance is categorically exempt from the California Environmental Quality Act (CEQA) pursuant to Sections 15061(b)(3), 15301 and 15302 of the CEQA Guidelines. Section 15301 provides exemp tion for a class of projects (Class 1) consisting of repair, maintenance or minor alterations to public or private structures or facilities involving negligible or no expansion of use. Section 15302 provides exemption for a class of projects (Class 2) con sisting of replacement or reconstruction of existing structures or facilities where the new structure or facility will be located on the same site and will have substantially the same purpose and capacity. The proposed ordinance 13 of 14 requires repair, maintenan ce and minor alterations of existing structures and facilities to meet minimum seismic safety standards. The ordinance does not require or contemplate any appreciable expansion or change in use or capacity of any existing structure or facility. According ly, the ordinance is categorically exemption pursuant to CEQA Guidelines Sections 15301 and 15302. Additionally, the proposed ordinance is also exempt pursuant to CEQA Guidelines Section 15061(b)(3) because, as described by this Staff Report, it can be se en with certainty that there is no possibility that the proposed ordinance could have a significant effect on the environment. Financial Impacts & Budget Actions There is no immediate financial impact or budget action necessary as a result of recommended action. S taff will return to Council if specific budget actions are required in the future. Concurrent with the FY 2017 -19 biennial City budget, a City -wide fee study will be presented. Included in the fee study will be fees related to the Seismic Retrof it Program which will allow a cost neutral program with no effect to the General Fund. The Program will not have impacts to the current 2016 -17 fiscal year budget as all requests are deferred to the FY 2017 -19 biennial budget. Prepared By: Ron Takiguchi, Building Officer Approved Forwarded to Council Attachments: A. Ordinance B. Resolution Local Geological Conditions 14 of 14 C. Inventory (List) D. December 6, 2016 Council Study Session Staff Report E. Written Comments F. PowerPoint Presentation G. PowerPoint Presentation 1 City Council Meeting : February 14 , 201 7 Santa Monica, California ORDINANCE NUMBER _________ (CCS) (City Council Series) AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF SANTA MONICA AMENDING ARTICLE S IV and VIII OF THE SANTA MONICA MUNICIPAL CODE BY UPDATING SEISMIC RETROFIT STANDARDS AND TENANT PROTECTION LAWS WHEREAS, t he City of Santa Monica is located in a geological area of high seismicity and prone to earthquakes of significant magnitude ; and WHEREAS, w orld leading experts and scientists in seismicity have predicted major seismic activity in the Southern California region in the near future with catastrophic destruction potential ; and WHEREAS, a fault line known as the Santa Monica Fault runs through the extent of the City and t he City of Santa Monica Safety Element has deemed the Santa Monica Fault an active earthquake fault ; and WHEREAS, e arthquakes and seismic activity are known to have the potential to cause significant damage to buildings and related occurrences of possible injur y, death, resident displacement, interruption to business and economic continuity ; and WHEREAS, Santa Monica’s inventory of older buildings have been proven to have substandard performance in earthquakes ; and 2 WHEREAS, p rior retrofit requirements of the City of Santa Monica resulted in the strengthening and retrofitting of some buildings, but many structures remain unretrofitted ; and WHEREAS, t he safety of the City’s residents, workforce, and visitors are of paramount concern to the City ; and WHEREA S, u pdating the City’s requirements for seismic retrofit and strengthening of buildings will allow greater performance of buildings during earthquakes and aftershocks and will lessen the chance of injury, death, and damage to buildings ; and WHEREAS, s eismic retrofit of older buildings will also provide a greater chance for continuity of building occupancy, business operation and resident habitation after a seismic event ; and WHEREAS, California Health and Safety Code Sections 19101, 19162 -63.6 authori ze and encourage local jurisdictions to establish seismic retrofit standards ; and WHEREAS, Health and Safety Code Section 18941.5 provides that the City may establish more restrictive building standards if they are reasonably necessary due to local climat ic, geological or topographical conditions ; and WHEREAS, based upon the findings contained in the Resolution adopted concurrently with this Ordinance, the City Council has found that certain modifications and additions to the California Building Standards Code , relating to seismic retrofit, are reasonably necessary based u pon local climactic, topographic, and geological conditions; and 3 WHEREAS, relocation benefits are vital to Santa Monica tenants including those who must vacate their homes for repairs nec essitated by law or government order or if their residence is rendered uninhabitable through no fault of their own ; and WHEREAS, benefits must be sufficient in length of time and in amount to cover actual relocation costs ; and WHEREAS, experience has show n that certain provisions within the existing relocation law have been subject to differing interpretations by landlords and tenants, and such differences in opinion can lead to unnecessary litigation and uncertainty; and WHEREAS, both tenants and landlord s will benefit from enhancements to the clarity and certainty of relocation requirements and obligations ; and WHEREAS, the City’s relocation requirements are intended to protect the rights of both tenants and landlords . NOW, THEREFORE, THE CITY COUNCIL OF THE CITY OF SANTA MONICA DOES HEREBY ORDAIN AS FOLLOWS: SECTION 1. Chapter 8.5 8 of the Santa Monica Municipal Code is hereby added to read as follows: Chapter 8.58 Mandatory Seismic Retrofit Administrative Requirements 8.58.010 Purpose and Scope. The provision s of this Chapter are intended to establish administrative and general requirements to ensure compliance with and facilitate implementation of the retrofit requirements set forth in Chapters 8.60, 8.64, 8.68, 8.72, 8.76, 8.80 of this Code. 8.58.020 Defini tions. 4 The following words and phrases as used to enforce the provisions of Chapters 8.58, 8.60, 8.64, 8.72, 8.76, and 8.80 shall have the following meanings: (a) “California Building Code” shall mean the 2016 edition of the California Building Standards Code. (b) “Santa Monica Seismic Retrofit Laws” shall mean Chapters 8.60, 8.64, 8.72, 8.76, and 8.80 of this Code. 8.58.030 General requirements. (a) Upon being ord ered by the Building Officer, an owner of a building within the scope of the Santa Monica Seismic Retrofit Laws shall perform a structural analysis of the building by a civil or structural engineer or architect licensed by the State of California, and if t he building does not meet the minimum earthquake standards specified in Santa Monica Seismic Retrofit Laws , the owner shall cause the building to be structurally retrofitted to conform to such standards. (b) Structural observation, in accordance with Cha pter 17 of the California Building Code, shall be required for all structures in which seismic retrofit is being performed. Structural observation shall include confirmations of work required for conformance with the approved construction documents and ex isting building elements that are part of the lateral force resisting system . Structural testing and inspection for new and existing construction materials shall be conducted in accordance with the California Building Code and other applicable standards. (c) Special inspection, in accordance with Chapter 17 of the California Building Code and other applicable codes and standards, shall be conducted to confirm work related to the seismic retrofitting of the building. Special inspections shall be conducted 5 by certified special inspectors. Special inspectors shall be hired by the building owner and shall provide reports of special inspection findings to the Building Officer. (d) The structural investigation, structural analysis report, and structural design plans for the seismic strengthening and retrofit for buildings within the scope of the Santa Monica Seismic Retrofit Laws shall be designed by a State of California licensed civil or structural engineer, or a State of California registered architect. Plan s and associated documents shall bear the seal and signature of the design professional. 8.58.040 Priority Designations. The Building Officer shall prioritize his or her enforcement efforts as follows: Priority 1. Unreinforced Masonry Buildings and Concret e Tilt -Up Building s Priority 2. Soft -Story Buildings with 3 or more stories Priority 3. Soft -Story Buildings with 16 or more units Priority 4. Non -Ductile Concrete Buildings and Steel Moment Frame Buildings Priority 5. Soft -Story Buildings with 7 to 15 Uni ts Priority 6. Soft -Story Buildings with 6 or Less Units 8.58.050 Compliance Time Limits. (a) Compliance time limits for buildings within the scope of the Santa Monica Seismic Retrofit Laws shall be based on the service date of original order issued by the Building Officer (b) Sale or transfer of title in the building shall not change compliance dates. 8.58.060 Issuance of Order. a) Service of Order. When the Building Officer determines that a building is within the scope of the Santa Monica Seismic Retrof it Laws , the Building Officer shall 6 issue an order to the owner(s) of the building to seismically evaluate and, if necessary, retrofit the building. For this purpose, the last known name and address of each property owner as contained in the records of th e Los Angeles County Assessor shall be used. The Building Officer shall serve the order in accordance with Section 1.12.080 of this Code. No person shall fail to comply with the Building Officer’s order. b) Proof of Service. Proof of giving notice shal l be made in accordance with Section 1.12.090 of this Code. c) Failure to Receive Notice. Failure of the owner to receive notice of an order shall not reli e ve the owner of any obligation to comply with the requirement to retrofit a building within the s cope the Santa Monica Seismic Retrofit Laws . d) Contents of Order. The order required by subsection (a) shall specify that the building has been determined by the Building Officer to be within the scope of the Santa Monica Seismic Retrofit Laws and shal l contain the following information: 1) Building Address 2) Assessor’s Parcel Number 3) Building Type 4) Year Built 5) The factual basis supporting the order 6) The relevant Santa Monica Municipal Code Sections outlining the retrofit standards with which t he building owner is required to comply 7) Compliance Timeframes 8) A description of the appeal process, including time frames within which the appeal must be filed. 7 8.58.070 Tenant and Occupant Advisory (a) When the Building Officer determines that a buil ding does not meet the minimum earthquake standards specified in the Santa Monica Seismic Retrofit Laws , the owner shall , within the time period established by the Building Officer, advise all current and prospective tenants, subtenants, lessees, and suble ases of the building. This requirement applies regardless of the length of time the person may use and/or occupy the building. (b) With respect to current tenants or lessees, the notice required by subsection (a) of th is Section shall be hand -delivered , with a proof of service, or sent by certified mail or otherwise delivered in a form of electronic means acceptable to the Building Officer. A copy of the Building Officer’s order shall meet the requirements of this Section. (c) With respect to current subtenants and subleases or prospective tenants, subtenants, lessees, and subleases, the owner shall advise such persons of the Building Officers determination in a method and written format approved by the Building Officer or designee. A copy of the Buil ding Officer’s order shall meet the requirements of this Section. 8.58.080 Appeals. Except as otherwise provided by Section 8.58.090 of this Code, the owner of any building may appeal any decision or order issued by the Building Officer pursuant to the Santa Monica Seismic Retrofit Laws, including but not limited to, the initial determination that a building is within the Scope of the Santa Monica Seismic Retrofit Laws or the conclusion that a building must be retrofitted, to the Building and Fire Life S afety Commission. Any such appeal shall be filed with the Commission within sixty days of the 8 date of the Building Officer’s order or decision. Any such appeal shall be decided by the Commission no later than ninety days after filing. The filing of an a ppeal would stay the underlying order or decision and the associated time limits. Should the appeal be denied by the Commission the initial time limits shall be restored, unless the Commission authorizes alternate time limits. The Commission’s decision s hall be final except for judicial review. 8.58.090 Extensions. (a) Notwithstanding any other provisions of this Code, e xtensions of time from the stated time limits set forth in the Santa Monica Seismic Retrofit Laws may be granted for good cause, provided that the building owner files a written request with the Director of Planning and Community Development or designee. (b) The decision of the Director of Planning and Community Development or designee may be appealed to a Hearing Examiner , pursuant to rele vant procedures set forth in Chapter 6.16 of this Code . The decision of the Hearing Examiner shall be final except for judicial review. (c) Notwithstanding any other provisions of this Code and upon good cause shown, t he Building Officer may extend a co nstruction permit issued solely for the purpose of retrofit ting a building to comply with Chapters 8.60, 8.64 , 8.68 , 8.72, 8.76, and 8.80 of this Code . 8.58.1 0 0 Parking Requirements. Notwithstanding any other provisions of this Code to the contrary, the Zoning Administrator, or designee, may reduce the size of required parking spaces or the number of required parking spaces, to the minimum extent necessar y, to achieve compliance with 9 t he requirements of the Santa Monica Seismic Retrofit Laws , if the building owner can show that there is no practicable method to complete the required retrofit without the reduction. The reduction in parking spaces shall not exceed 20% of required parking spaces or one (1) space, whichever is greater. Nothing in this section shall be intended to reduce, change, or eliminate an owner’s obligations under the Rent Control laws. 8.58.110 Exception to Construction Rate Program Notwithstanding any other provisi ons of this Code to the contrary, c onstruction projects undertaken solely for the purpose of comply ing with the Santa Monica Seismic Retrofit Laws shall be exempt from the Construction Rate Program set forth in Section 9.37.110 of this Code. 8.58.120 Trash Screening and Enclosure Requirements. Notwithstanding any other provisions of this Code to the contrary, the Public Works Director, or designee, may waive or reduce the requirements of Section 9.21.130 (Resource Recovery and Recycling Standards) of this Code, to the minimum extent necessary, if the building owner can show that there is no practicable method to complete the required retrofit and comply with Section 9.21.130. 8.58.130 Recordation Upon the Building Officer’s determination that a buildi ng must be seismically retrofitted to meet the minimum standards set forth in the Santa Monica Seismic Retrofit Laws , the Building Officer may file with the County of Los Angeles , Office of the Registrar/Recorder, a certificate stating that the subject building fails to meet the minimum standards set forth in the Santa Monica Seismic Retrofit Laws and that it must be retrofitted . If the building is subsequently retrofitted to meet the requirements of the 10 Santa Monica Seismic Retrofit Laws , or is demolis hed with City authorization, then the Building Officer shall file with the County of Los Angeles , Office of the Registrar/Recorder, a certificate indicating that the building or property has been brought into compliance with the Santa Monica Seismic Retrof it Laws . SECTION 2. Chapter 8.60 of the Santa Monica Municipal Code is hereby amended to read as follows: Chapter 8.60 Mandatory Seismic Retrofit Requirements for Unreinforced Masonry Bearing Wall Buildings SEISMIC STRENGTHENING PROVISIONS FOR UNREINFORCED MASONRY BEARING WALL BUILDINGS 8.60.010 Adoption Scope . Appendix Chapter A1 of the California Existing Building Cod e 2016 Edition, entitled “Seismic Strengthening Provisions for Unreinforced Masonry Bearing Wall Buildings” which adopts by reference Appendix Chapter A1 of the International Existing Building Code, 2015 Edition, as published by the California Building St andards Commission and the International Code Council, (excluding Sections A101, A102, A105, A114, Table A1 - G), is hereby adopted as the Mandatory Seismic Retrofit Requirements for Unreinforced Bearing Wall Buildings, of the City of Santa Monica. The provisions of this Chapter shall apply to all existing unreinforced masonry bearing wall buildings built under valid permit, including detached one - or two -family dwellings and detached apartment houses containing less than five dwelling units. The provisi ons of the Chapter also apply to essential and hazardous facilities. Such buildings or structures shall be strengthened to meet the requirements of the Building Code of the City of Santa Monica for new buildings of the same occupancy category. 11 Buildings de signated as historically or architecturally significant landmarks on national, state or local historical registers shall comply with the provisions of this Chapter. At the Building Officer’s discretion, modifications to the retrofitting standards set forth in this Chapter may be made so long as such modifications are consistent with the provisions of the State Historic Building Code. 8.60.020 Purpose Definitions . The purpose of this Chapter is to enhance public safety by providing improved measures for seismic strengthening to unreinforced masonry bearing wall buildings (“URM Buildings”) and reducing risks from the effect of seismic activity. This Chapter and the requ irements for mandatory seismic strengthening and retrofit, addresses the hazards of URM Buildings and associated elements of these buildings that are unreinforced such as non -bearing masonry walls and parapets. This Chapter and the requirements therein are considered minimum standards for structural seismic resistance. They are intended to provide a greater measure of safety through improved performance of URM Buildings. Compliance with this Chapter does not ne cessarily prevent the loss of life or injury or damage to retrofitted URM Buildings. For the purposes of this Chapter, the definitions in the Building Code and the following shall apply: Building Code is the Building Code of the City of Santa Monica. Ini tial determination is the date of service for the order of the Building Officer pursuant to this Chapter to the owner of any building informing him or her that he or she are subject to the strengthening provisions of this Chapter or Chapter 8.56 . Subsequen t change in ownership shall not change the date of initial determination. 12 Type I building is any unreinforced masonry bearing wall building that must be usable in the event of an emergency, and shall include hospitals, police and fire stations and disaster recovery centers. Type II building is any unreinforced masonry bearing wall building with one hundred or more occupants and without masonry shear walls or wood frame cross -walls spaced less than forty feet apart in each story. Type III building is any unr einforced masonry bearing wall building with one of the following conditions: (1) One hundred or more occupants and with masonry or wood frame cross -walls spaced less than forty feet apart in each story. (2) At least twenty but fewer than one hundred occup ants. Type IV building is any unreinforced masonry bearing wall building with fewer than twenty occupants. Unreinforced masonry bearing wall building is any building that has at least one masonry wall in which the reinforcing steel is less than twenty -five percent of the minimum steel ratios required by the California Building Code for reinforced masonry and such wall provides the vertical support for the reaction of floor or roof -framing members. 8.60.030 Scope and Applicability General requirements . (a) The provisions of this Chapter shall apply to all buildings built under building code standards enacted before January 1 1 , 197 7 that contain any unreinforced masonry bearing or non -bearing walls or attachments and appurtenances (“URM Buildings”). 13 (b) An owner of any buildings within the scope of this Chapter shall demonstrate compliance with the Mandatory Seismic Retrofit Requi rements of this Chapter consistent with the time limits set forth in this Chapter. (c) URM Buildings that have completed all required seismic retrofit work , with a lateral load resisting analysis and structural design plans, and obtained valid final approval from the City of Santa Monica prior to the adoption of this Ordinance , are exempt from the requirements this Chapter , except that: Tall slender URM Buildings with wall height to thickness ratio of thirteen or greater (>=1 3) shall be subject to the requirements of this Chapter regardless o f previously retrofit status . (a) The owner of each building within the scope of this Chapter shall, within the time limits set forth in this Chapter, cause the building to be structurally altered to conform to the earthquake standards specified in this Chapter. (b) The owner of each building within the scope of this Chapter, which has been analyzed to demonstrate compliance or has been structurally altered to comply with the mi nimum earthquake standards in this Chapter, shall maintain such building in conformity with the requirements of this Chapter in effect at the time of such analysis or structural alteration. (c) Buildings within the scope of this Chapter may not be added to or structurally altered or otherwise remodeled without first complying with the provisions of this Chapter unless the Building Officer determines that the alterations are minor in nature. 14 (d) Notwithstanding any other provisions of this Code to the contra ry, it shall be unlawful for any person, firm or corporation to maintain, use or occupy any building within the scope of this Chapter which does not meet the minimum earthquake standards specified in this Chapter. This provision shall not apply if alterati on or repair work has commenced to bring the building into compliance with requirements of this Chapter, and such work is proceeding in accordance with the time limits set forth in any order of the Building Officer or determination of the Nuisance Abatemen t Board. 8.60.040 Demolition. An owner desiring to demolish a building must nevertheless comply with the strengthening provisions of this Code within the time allowed unless such owner receives permission to demolish the building prior to the time limits set forth in this Chapter for the filing of a permit and the submitting of plans to the Building Officer. Such an owner shall submit a demolition permit applica tion to the Building Officer and shall meet all of the requirements for demolition imposed by this Code, including, but not limited to, those requirements set forth in Section 9.04.10.16.010 of this Code, before such a demolition shall be permitted. Nothin g in this Chapter shall be deemed to relieve a building owner of meeting the requirements for demolition of a building imposed by any other applicable law or regulation. 8.60.050 Time limits for compliance Seismic provisions . The owner of any URM Building covered by this Chapter shall comply with the following time limits. Action by Building Owner Time Limits from Date of Service of Order 15 Structural Evaluation Report 90 Days or 3 Months Application for Building Permit and Submission of Plans 180 Days or 6 Months Final Approval 2 Years or 24 Months (a) Essential and Hazardous Facilities. Essential and hazardous facilities shall be strengthened to meet the requirements of the Building Code of the City of Santa Monica for new buildings of the same occupancy category. (b) All Other Buildings. All buildings, other than essential or hazardous facilities, shall be strengthened to meet the requirements of Appendix Chapter A1 of the California Existing Building Code and the additional provisions of this Chapter . 8.60.060 Timetable for compliance. The time limits set forth below shall begin to run from September 29, 1992, or from initial determination, whichever is later. The owner of any occupied or vacant building within the scope of this Chapter sh all comply with the requirements of this Chapter by filing for a permit, submitting plans to the Building Officer, commencing construction and completing construction within the time limits specified below: Such plans shall be prepared by a State of Califo rnia licensed architect or registered civil or structural engineer. After plans are filed and approved by the Building Officer, the owner shall obtain a building permit and then commence and complete the required construction within the time limits set for th below. 16 An owner electing to install wall anchors pursuant to the provisions of this Chapter is also required to structurally alter the building to make it fully comply with all other provisions of this Chapter within the time limits set forth in Table 8 .60 -A below. Table 8.60 -A Required Action by Owner Building Type File for Permit and Submit Plans to Building Officer Within Commence Construction Within Complete Construction Within A. Install wall anchors Type I, II, III, IV 180 days 270 days 1 year B. If wall anchors are installed, then make structural alterations Type I 635 days (1 year 9 months) 2 years 4 years Type II 635 days (1 year 9 months) 2 years 4 years Type III 2,825 days (7 years 9 months) 8 years 10 years Type IV 2,825 days (7 years 9 months) 8 years 10 years C. If wall anchors are not installed, then make structural alterations Type I 270 days 1 year 2 years Type II 270 days 1 year 2 years Type III 1,000 days (2 years 9 months) 3 years 4 years Type IV 1,365 days (3 years 9 months) 4 years 5 years 17 8.60.070 Administration. (a) Building Classification. The Building Officer shall determine the occupant load and classification of building type. The occupant load shall be determined in accordance with the Building Code and shall include the entire building plus the occupant load of any adjacent building th at interconnects with the subject building or uses the subject building for exiting purposes. (b) Contents of Order. When the Building Officer determines that a building is within the scope of this Chapter, the Building Officer shall issue an order as prov ided herein. The order shall specify that the building has been determined by the Building Officer to be within the scope of this Chapter and, therefore, is required to meet the seismic strengthening provisions of this Chapter. The order shall specify the Building Type classification and shall set forth the owner’s alternatives and time limits for compliance. (c) Service of Order. The order shall be in writing and may be given either by personal delivery thereof to the owner or by deposit in the United States mail in a sealed envelope, postage prepaid, addressed to the owner as shown on the last equalized assessment roll. Service b y mail shall be deemed to have been completed at the time of deposit in the U.S. mail. The failure of any owner to receive such notice shall not affect in any manner the validity of any of the proceedings taken thereunder. Proof of giving notice may be mad e by an affidavit of any employee of the City which shows service in conformity with this Section. Building and Fire Life Safety Commission action, Nuisance Abatement Board action, Building Officer administrative action, other correspondence 18 between the Ci ty and the building owner or building owner’s representative, or other evidence of knowledge of notification shall also be deemed as proof of giving notice. (d) Recordation. At the time that the Building Officer serves the aforementioned order, the Buildin g Officer shall file with the Office of the County Recorder a certificate stating that the subject building is within the scope of this Chapter. The certificate shall also state that the building owner thereof has been ordered to structurally analyze the b uilding and to structurally alter it if the Building Officer determines the building is not in compliance with this Chapter. If the building is either demolished, found not to be within the scope of this Chapter, or is structurally capable of resisting min imum seismic forces required by this Chapter as a result of structural alterations or an analysis, the Building Officer shall file with the Office of the County Recorder, a certificate terminating the status of the subject building as being classified with in the scope of this Chapter. 8.60.080 Appeals. (a) Initial Determination. The owner of any building may appeal the Building Officer’s initial determination that the building is within the scope of this Chapter to the Building and Fire Life Safety Commission. Such appeal shall be filed with the Commission by December 28, 1992, o r within ninety days of date of initial determination, whichever is later. Any such appeal shall be decided by the Building and Fire Life Safety Commission no later than ninety days after filing and the grounds thereof shall be stated clearly and concisely . 19 (b) Abatement Proceedings. Appeals or requests for modifications from any other determinations, orders, or actions by the Building Official pursuant to this Chapter may be made to the Building and Fire Life Safety Commission. 8.60.090 Enforcement. If the owner in charge or control of the subject building fails to comply with this Code within any of the time limits set forth herein, the Building Officer may order tha t the entire building be vacated and that the building remain vacated until this Code has been complied with. If compliance has not been initiated within ninety days after the date the building has been ordered vacated or such additional time as may have b een granted by the Nuisance Abatement Board, the Building Officer may: (a) Commence the building’s demolition in accordance with the provisions of the California Building Code ; or (b) Undertake and complete such structural alteration of the building as may be necessary in the sole judgment of the Building Officer to cause the building to conform to the earthquake standards specified in this Chapter, and to cause a lien for the costs of such structural alteration to be placed against the property. No demolit ion may occur pursuant to this Section without compliance with all City laws and regulations governing demolitions. 8.60.100 Temporary stay of enforcement based on seve re financial hardship. (a) The owner of any building may appeal for a temporary stay of enforcement on the basis of severe financial hardship from compliance with this Chapter. Such appeal shall be filed with the City’s Director of Finance no later than February 26, 1993. 20 (b) Any such appeal shall be decided by the Director of Finance no later than ninety days after filing and the grounds thereof shall be stated clearly and concisely. (c) The burden shall be on the owner to demonstrate conclusively that compliance with this Section shall result in severe financial hardship. Documentary evidence shall be submitted by the owner at the time the appeal is filed and shall clearly demonstrate that compliance with this Section shall result in severe financial ha rdship. Such documentary evidence may include, but shall not be limited to, the owner’s tax returns, general ledgers, rental and lease agreements, personal and corporate income and expense records, and any such other financial documents or information as t he owner desires to submit for consideration or as the City’s Director of Finance deems necessary or desirable in evaluating the owner’s claim of hardship. The failure of the owner to provide any financial document or information requested by the Director of Finance shall result in denial of the request for a temporary stay of enforcement. (d) Any person denied a temporary stay of enforcement by the Director of Finance may appeal the denial to a three -person Financial Hardship Appeal Board established by th e City Manager. Any such appeal shall be made in writing within ten days of the denial and shall be based on the evidence supplied to Director of Finance. The Appeal Board may approve or deny any appeal and may relieve an owner from full or partial complia nce with the requirements of this Chapter, as the Appeal Board in its sole discretion deems financially feasible. The decision of the Financial Hardship Appeal Board shall be final except for judicial review and shall not be appealable to the City Council. The Appeal Board is authorized to establish procedures for the processing and consideration of appeals. 21 (e) In any case where a building is exempted from compliance with this Chapter on the basis of financial hardship, such exemption shall be null and voi d and of no further force or effect at the time the building is sold or experiences a major change of occupancy as defined by the Building Officer. 8.60.110 Canopies. Prior to commencement of construction of any of the structural alterations required by this Chapter, a pedestrian protection canopy shall be constructed below any unreinforced masonry wall adjacent to any public right -of -way. Said canopy shall conform to the standards developed by the Director of Public Works. 8.60.120 Shear test criteria for mortar quality. (a) Test Equipment. An internal caliper, graduated in 0.001 of an inch (0.025 mm) increments shall be used to measure movement of the masonry unit. A hydraulic jack equipped with a pressure gauge graduated in increments of fifty psi (345 kPa) or less shall be used. The jack load shall be applied at a rate not exceeding five thousand pounds (22,240 N) per minute. (b) Minimum Number of Technicians and Test Readings. The test shall be conducted by a minimum of two technicians. Load and displacement readings shall be recorded at the following intervals: (1) At a caliper reading of 0.001 inch (0.025 mm); (2) At the first visually observed sign of movement or cracking of the mortar or masonry unit; (3) At a caliper reading of 0.02 inch (0.51 mm); and (4) The ultimate load on the uni t. 22 (c) Representative Test Locations. The masonry unit to be tested shall not be located adjacent to a bond course in a brick wall laid in common bond. Tests to evaluate the mortar quality of structural walls shall not be conducted in masonry veneer. Walls with mortar values which are consistently low and do not meet the minimum quality values specified in this Section shall be entirely pointed per standards referenced in the California Building Code , except that the depth of joint penetration shall be one and one -half inch (38 mm) in lieu of the three -fourths inch (19 mm) specified. (d) Core Tests. A minimum number of mortar test specimens equal to the number of required cores shall be prepared from the cores and tested as specified herein. The mortar joint of the outer wythe of the masonry core shall be tested in shear by placing the circular core section in a compression testing machine with the mortar bed joint rotated fifteen degrees from the axis of the applied load. The mortar joint tested in shear sha ll have an average ultimate stress of twenty psi (138 kPa) based on the gross area. The average shall be obtained from the total number of cores made. If test specimens cannot be made from cores taken, the shear value shall be reported as zero. SECTION 3. Chapter 8.64 of the Santa Monica Municipal Code is hereby amended to read as follows: Chapter 8.64 Mandatory Seismic Retrofit Requirements for Existing Concrete and Reinforced Masonry Wall Buildings with Flexible Diaphragms SEISMIC STRENGTHENING PROVISIONS FOR EXISTING CONCRETE AND REINFORCED MASONRY WALL BUILDINGS WITH FLEXIBLE DIAPHRAGMS 8.64.010 Adoption Purpose . 23 Appendix Chapter A2 entitled “Earthquake Hazard Reduction in Existing Reinforced Concrete and Reinforced Masonry Wall Buildings with Flexible Diaphragms” of the International Existing Building Code, 2015 Edition, as published by the International Code Council (excluding Secti on A201, A202, A203, A204, A205, A207) is hereby adopted as the Mandatory Seismic Retrofit Requirements for Existing Concrete and Reinforced Masonry Wall Buildings with Flexible Diaphragms of the City of Santa Monica. The purpose of this Chapter is to promote public safety and welfare by reducing the risk of death or injury that may result from the effects of earthquakes on concrete and reinforced masonry wall buildings with flexible diaphragms designed under the buildi ng codes in effect prior to the 1992 California Building Code . Past earthquakes have shown that such buildings are potentially hazardous and prone to significant damage, including possible collapse, in a moderate to major earthquake. This Chapter provides priorities, time periods and standards under which these buildings are required to be structurally analyzed and strengthened for seismic resistance. Where the analysis determines that structural deficiencies exist, this Chapter requires the building to be strengthened. 8.64.020 Purpose Scope . The purpose of this Chapter is to enhance public safety by providing an improved component of seismic strengthening to existing concrete and reinforced masonry wall buildings with flexible diaphragms and reducing risks from the effect of earthquakes. This Chapter addresses the hazards of these buildings by establishing requirements for the analysis, design of structural strengthen ing elements, and seismic retrofit of these buildings. 24 This Chapter and the requirements therein are considered minimum standards for structural seismic resistance. They are intended to provide a greater measure of safety through improved performance of existing concrete and reinforced masonry wall buildings with flexible diaphragms. Compliance with this Chapter does not necessarily prevent the loss of life or injury or damage to retrofitted buildings. (a) The provisions of this Chapter apply to all exis ting concrete or reinforced masonry buildings with flexible diaphragms, including tilt -up concrete wall buildings, designed under the building codes in effect prior to the 1992 California Building Code . (b) Buildings designated as historically or architect urally significant landmarks on national, state or local historical registers shall also comply with the provisions of this Chapter. At the Building Officer’s discretion, modifications to the standards set forth in this Chapter may be permitted when such m odifications are consistent with the provisions of the State Historical Building Code. (c) This Chapter requires the wall anchorage system, as defined herein, to be analyzed, designed and strengthened in conformance with the earthquake design standards of the Building Code of the City of Santa Monica in effect at the time of permit issuance for the strengthening work. (d) Seismic strengthening in place prior to December 12, 1995, shall be evaluated according to the provisions of this Chapter and modified to comply if deficient. 8.64.030 Scope and Applicability Definitions . The provisions of this Chapter shall apply to all concrete or reinforced masonry buildings with flexible diaphragms, including tilt -up concrete wall buildings, built under building code standards enacted before January 1, 199 6 . 25 Concrete or reinforced masonry buildings with flexible diaphragms, including tilt - up concrete wall buildings that have com pleted all required seismic retrofit work, with a lateral load resisting analysis and structural design plans, and obtained valid final approval from the City of Santa Monica prior to the adoption of this Ordinance , are exempt from the requirements this Ch apter. An owner of any building within the scope of this Chapter shall demonstrate compliance with the Mandatory Seismic Retrofit Requirements of this Chapter consistent with the time limits set forth in this Chapter. For purposes of this Chapter, the applicable definitions in the Building Code of the City of Santa Monica and the following shall apply: Anchorage system is the system of all structural elements and connections which support the concrete or masonry wall in the lateral direction, including diaphragms and subdiaphragms, wall anchorage and continuity or cross tie connectors in subdiaphragms and main diaphragms for retrofit and repairs. Building Code is the Building Code of the City of Santa Monica. Commenced construction is construction pursua nt to a valid building permit that has progressed to the point that one of the called inspections as required by the Building and Safety Division has been made and the work for which the inspection has been called has been judged by the Building and Safety Division to be substantial and has been approved by the Building and Safety Division. Concrete wall building is, for the purposes of this Chapter, any building that has at least one concrete wall which may or may not have sufficient reinforcing steel as r equired by the Building Code. 26 Date of engineering report submittal is either that date upon which the report was due to be submitted to the City, or the date of actual submittal to the City, whichever is earlier. Existing building is any building, which as of December 12, 1995, has been issued a certificate of occupancy or has been legally occupied. Expansion anchor is a mechanical fastener placed in hardened concrete or assembled masonry, designed to expand in a self -drilled or predrilled hole of a specifi ed size and engage the sides of the hole in one or more locations to develop shear and/or tension resistance to applied loads without grout, adhesive or drypack. Flexible diaphragm is, for the purposes of this Chapter, any diaphragm constructed of wood str uctural panel, diagonal or straight wood sheathing or decking, metal decking without a structural concrete topping, or horizontal rod bracing. Reinforced masonry wall building is, for the purposes of this Chapter, a building that has at least one masonry w all which has twenty -five percent or more of the reinforcing steel ratios required by the Building Code for reinforced masonry and is not classified as an unreinforced masonry wall building pursuant to Chapter 8.60 of the Municipal Code. Retrofit is an improvement of the lateral force resisting system of the structure by an alteration of existing or addition of new structural elements. Tilt -up concrete wall is a form of precast concrete panel construction either cast in the horizontal position at the site and after curing, lifted and moved into place in a vertical position, or cast off -site in a fabricator’s shop. 27 Type I building is any concrete wall or reinforced masonry wall building that must be usable in the event of an emergency, and shall include hospitals, police and fire stations and disaster recovery centers. Type II building is any concrete wall or reinforced masonry wall building with one hund red or more occupants. Type III building is any concrete wall or reinforced masonry wall building with at least twenty but fewer than one hundred occupants. Type IV building is any concrete wall or reinforced masonry wall building with fewer than twenty oc cupants. 8.64.040 Definitions General requirements . For purposes of this Chapter, applicable definitions in the California Building Code and the following shall apply: Anchorage system is the system of all structural elements and connections which support the concrete or masonry wall in the lateral direction, including diaphragms and subdiaphragms, wall anchorage and continuity or cross tie connectors in subdiaphr agms and main diaphragms for retrofit and repairs. Expansion anchor is a mechanical fastener placed in hardened concrete or assembled masonry, designed to expand in a self -drilled or predrilled hole of a specified size and engage the sides of the hole in one or more locations to develop shear and/or tension resistance to applied loads without grout, adhesive or drypack. Flexible diaphragm is any diaphragm constructed of wood structural panel, diagonal or straight wood sheathing or decking, metal decking without a structural concrete topping, or horizontal rod bracing. 28 Rein forced masonry wall building is a building with masonry wall s which ha ve twenty -five percent or more of the reinforcing steel ratios required by the Building Code for reinforced masonry and is not classified as an unreinforced masonry wall building pursuan t to Chapte r 8.60 o f the Santa Monica Municipal Code. Tilt -up concrete wall is a form of precast concrete panel construction either cast in the horizontal position at the site or cast off -site in a fabricator’s shop, and then lifted and moved into place in a vertical position. (a) The owner of each building within the scope of this Chapter shall cause an investigation of the existing construction and a structural analysis to be made of the building by a civil or structural engineer or architect licensed by the State of California, and if the building does not meet the minimum standards specified in this Chapter, the owner shall cause it to be structurally altered to conform to such standards. (b) The owner of each building within the scope of this Chapter, which has been analyzed to demonstrate compliance or structurally altered to comply with the minimum earthquake standards in this Chapter, shall maintain such building in conformity with the requirements of this Chapter in effect at the time of such analys is or structural alteration. (c) Buildings within the scope of this Chapter may not be added to or structurally altered or otherwise remodeled without first complying with the provisions of this Chapter unless the Building Officer determines that the alter ations are minor in nature. (d) Notwithstanding any other provisions of this Code to the contrary, it shall be unlawful for any person, firm or corporation to maintain, use or occupy any building within the scope of this Chapter which does not meet the min imum earthquake standards specified in this Chapter. 29 This provision shall not apply if alteration or repair work has commenced to bring the building into compliance with requirements of this Chapter, and such work is proceeding in accordance with the time limits set forth in any order of the Building Officer or determination of the Nuisance Abatement Board. 8.64.050 Engineering Analysis and D esign Demolition . (a) Reinforced concrete and reinforced masonry wall anchorage. Concrete and masonry walls shall be anchored to all floors and roofs that provide lateral support for the wall. The anchorage shall provide a positive direct connection between the wall and floor or roof construction capable of resisting 75 percent of the horizontal forces specified in Chapter 16 of the California Building Code. (b) Special requirements for wall anchorage systems. The steel elements of the wall anchorage system shall be designed i n accordance with the building code without the use of the 1.33 short duration allowable stress increase when using allowable stress design. Wall anchors shall be provided to resist out -of -plane forces, independent of existing shear anchors. Exception: Ex isting cast -in -place shear anchors are allowed to be used as wall anchors if the tie element can be readily attached to the anchors, and if the engineer or architect can establish tension values for the existing anchors through the use of approved as -built plans or testing and through analysis showing that the bolts are capable of resisting the total shear load (including dead load) while being acted upon by the maximum tension force due to an earthquake. 30 Expansion anchors are only allowed with special ins pection and approved testing for seismic loading. Attaching the edge of plywood sheathing to steel ledgers is not considered compliant with the positive anchoring requirements of this Chapter. Attaching the edge of steel decks to steel ledgers is not cons idered as providing the positive anchorage of this Chapter unless testing and/or analysis are performed to establish shear values for the attachment perpendicular to the edge of the deck. Where steel decking is used as a wall anchor system, the existing co nnections shall be subject to field verification and the new connections shall be subject to special inspection. (c) Development of anchor loads into the diaphragm. Development of anchor loads into roof and floor diaphragms shall comply with Chapter 16 of the California Building Code using horizontal forces that are 75 percent of those used for new construction. Exception: If continuously tied girders are present, th e maximum spacing of the continuity ties is the greater of the girder spacing or 24 feet (7315 mm). In wood diaphragms, anchorage shall not be accomplished by use of toenails or nails subject to withdrawal. Wood ledgers, top plates or framing shall not be used in cross grain bending or cross grain tension. The continuous ties required in Chapter 16 of the California Building Code shall be used in addition to the diaphragm sheathing. Lengths of development of anchor loads in wood diaphragms shall be based o n existing field nailing of the sheathing unless existing edge nailing is positively identified on the original construction plans or at the site. 31 (d) Anchorage at pilasters. Anchorage at pilasters shall be designed for the tributary wall -anchoring load per Section 8.64.050(a), considering the wall as a two -way slab. The edges of the two -way slab shall be considered fixed when there is continuity at pilasters and shall be considered pinned at roof and floor. The pilasters or the walls immediately adjacent to the pilasters shall be anchored directly to the roof framing such that the existing vertical anchor bolts at the top of the pilasters are bypassed without permitting tension or shear failure at the top of the pilasters. Exception: If existing vertical anch or bolts at the top of the pilasters are used for the anchorage, additional exterior confinement shall be provided as required to resist the total anchorage force. The minimum anchorage force at a floor or roof between the pilasters shall be that specified in Section 8.64.050(a). (e) Symmetry . Symmetry of wall anchorage and continuity connectors about the minor axis of the framing member is required. Exception: Eccentricity may be allowed when it can be shown that all components of forces are positively resist ed. The resistance must be supported by calculations or tests. (f) Combination of anchor types. New anchors used in combination on a single framing member shall be of compatible behavior and stiffness. (g) Anchorage at interior walls . Existing interior reinforced concrete or reinforced masonry walls that extend to the floor above or to the roof diaphragm shall be anchored for out -of -plane forces per Sections 8.64.050(a) and (c). Walls extending through the roof diaphragm shall be anch ored for out -of -plane forces on both sides, and 32 continuity ties shall be spliced across or continuous through the interior wall to provide diaphragm continuity. (h) Collectors. If collectors are not present at reentrant corners or interior shear walls, they s hall be provided. Existing or new collectors shall be designed for the capacity required to develop into the diaphragm a force equal to the lesser of the rocking or shear capacity of the reentrant wall or the tributary shear based on 75 percent of the hori zontal forces specified in Chapter 16 of the California Building Code. The capacity of the collector need not exceed the capacity of the diaphragm to deliver loads to the collector. A connection shall be provided from the collector to the reentrant wall to transfer the full collector force (load). If a truss or beam other than a rafter or purlin is supported by the reentrant wall or by a column integral with the reentrant wall, then an independent secondary column is required to support the roof or floor me mbers whenever rocking or shear capacity of the reentrant wall is less than the tributary shear. (i) Mezzanines . Existing mezzanines relying on reinforced concrete or reinforced masonry walls for vertical and/or lateral support shall be anchored to the walls f or the tributary mezzanine load. Walls depending on the mezzanine for lateral support shall be anchored per Sections 8.64.050(a), (b), (c). Exception: Existing mezzanines that have independent lateral and vertical support need not be anchored to the walls. An owner desiring to demolish a building must nevertheless comply with the strengthening provisions of this Code within the time allowed unless such owner receives permission to demolish the building prior to the time limits set forth in Section 8.64.060 of 33 the Municipal Code for the filing of a permit and the submitting of plans to the Building Officer. Such an owner shall submit a demolition permit application to the Building Officer and shall meet all of the requirements for demolition imposed by this Code including, but not limited to those requirements set forth in Section 9.04.10.16.010 of this Code, before such a demolition shall be permitted. Nothing in this Chapter shall be deemed to relieve a building owner of meeting the requirements for demolit ion of a building imposed by any other applicable law or regulation. 8.64.060 Time period for compliance. Engineering Report. Within two hundred seventy -five days of the date of notice to the owner by the City, the owner of any tilt -up building constructed to pre -1992 California Building Code standards shall submit an engineering report to the Building and Safety Division. The r eport shall demonstrate whether the structure conforms to the earthquake design standards contained in the Building Code of Santa Monica in effect at the time the report is submitted to the City. If the report concludes the structure does not comply with t he standards, the structure shall be strengthened to comply with the standards within the time periods shown in Table 8.64 -A below. Table 8.64 -A Building Type Time Limits for Owner File for Permit/Submit Plans Commence Construction Complete Construction I 60 days from date of engineering report submittal 150 days from date of engineering report submittal 1 year from date of engineering report submittal 34 II 180 days from date of engineering report submittal 270 days from date of engineering report submittal 3 years from date of engineering report submittal III 1 1/2 years from date of engineering report submittal 1 year 8 months from date of engineering report submittal 3 years from date of engineering report submittal IV 2 years 5 months from date of engineering report submittal 2 years 8 months from date of engineering report submittal 4 years from date of engineering report submittal 8.64.070 Time limits for compliance Administration . The owner of any building covered by this Chapter shall comply with the following time limits. Action by Building Owner Time Limits from Date of Service of Order Structural Evaluation Report 120 Days or 4 Months Application for Building Permit and Submission of Plans 270 Days or 9 Months Final Approval 3 Years or 36 Months (a) Building Classification. The Building Officer shall determine the occupant load and classification of building type. The occupant load shall be determined in accordance with the Building Code and shall include the entire building plus the occupant load of any adjacent building th at interconnects with the subject building or uses the subject building for exiting purposes. (b) Contents of Order. When the Building Officer determines that a building is within the scope of this Chapter, the Building Officer shall issue an order as prov ided herein. 35 The order shall specify that the building has been determined by the Building Officer to be within the scope of this Chapter and, therefore, is required to meet the seismic strengthening provisions of this Chapter. The order shall specify the Building Type classification shall set forth the owner’s alternatives and time limits for compliance. (c) Service of Order. The order shall be in writing and may be given either by personal delivery thereof to the owner or by deposit in the United States m ail in a sealed envelope, postage prepaid, addressed to the owner as shown on the last equalized assessment roll. Service by mail shall be deemed to have been completed at the time of deposit in the U.S. mail. The failure of any owner to receive such notic e shall not affect in any manner the validity of any of the proceedings taken thereunder. Proof of giving notice may be made by an affidavit of any employee of the City which shows service in conformity with this Section. Building and Fire Life Safety Comm ission action, Nuisance Abatement Board action, Building Officer administrative action, other correspondence between the City and the building owner or building owner’s representative, or other evidence of knowledge of notification shall also be deemed as proof of giving notice. (d) Recordation. At the time the Building Officer serves the aforementioned order, the Building Officer shall file with the Office of the County Recorder a certificate stating that the subject building is within the scope of this Ch apter. The certificate shall also state that the owner thereof has been ordered to structurally analyze the building and to structurally alter it when the Building Officer determines the building is not in compliance with this Chapter. If the building is e ither demolished, found not to be within the scope of this Chapter, or is structurally capable of resisting minimum seismic forces required by this Chapter as 36 a result of structural alterations or an analysis, the Building Officer shall file with the Offic e of the County Recorder a certificate terminating the status of the subject building as being classified within the scope of this Chapter. 8.64.070 Administration. (a) Building Classification. The Building Officer shall determine the occupant load and classification of building type. The occupant load shall be determined in accordance with the Building Code and shall include the entire building plus the occupant loa d of any adjacent building that interconnects with the subject building or uses the subject building for exiting purposes. (b) Contents of Order. When the Building Officer determines that a building is within the scope of this Chapter, the Building Officer shall issue an order as provided herein. The order shall specify that the building has been determined by the Building Officer to be within the scope of this Chapter and, therefore, is required to meet the seismic strengthening provisions of this Chapter. The order shall specify the Building Type classification shall set forth the owner’s alternatives and time limits for compliance. (c) Service of Order. The order shall be in writing and may be given either by personal delivery thereof to the owner or by d eposit in the United States mail in a sealed envelope, postage prepaid, addressed to the owner as shown on the last equalized assessment roll. Service by mail shall be deemed to have been completed at the time of deposit in the U.S. mail. The failure of an y owner to receive such notice shall not affect in any manner the validity of any of the proceedings taken thereunder. Proof of giving notice may be made by an affidavit of any employee of the City which shows service in 37 conformity with this Section. Build ing and Fire Life Safety Commission action, Nuisance Abatement Board action, Building Officer administrative action, other correspondence between the City and the building owner or building owner’s representative, or other evidence of knowledge of notifica tion shall also be deemed as proof of giving notice. (d) Recordation. At the time the Building Officer serves the aforementioned order, the Building Officer shall file with the Office of the County Recorder a certificate stating that the subject building i s within the scope of this Chapter. The certificate shall also state that the owner thereof has been ordered to structurally analyze the building and to structurally alter it when the Building Officer determines the building is not in compliance with this Chapter. If the building is either demolished, found not to be within the scope of this Chapter, or is structurally capable of resisting minimum seismic forces required by this Chapter as a result of structural alterations or an analysis, the Building Offi cer shall file with the Office of the County Recorder a certificate terminating the status of the subject building as being classified within the scope of this Chapter. 8.64.070 Administration. (a) Building Classification. The Building Officer shall determine the occupant load and classification of building type. The occupant load shall be determined in accordance with the Building Code and shall include the entire building plus the occupant load of any adjacent building th at interconnects with the subject building or uses the subject building for exiting purposes. 38 (b) Contents of Order. When the Building Officer determines that a building is within the scope of this Chapter, the Building Officer shall issue an order as prov ided herein. The order shall specify that the building has been determined by the Building Officer to be within the scope of this Chapter and, therefore, is required to meet the seismic strengthening provisions of this Chapter. The order shall specify the Building Type classification shall set forth the owner’s alternatives and time limits for compliance. (c) Service of Order. The order shall be in writing and may be given either by personal delivery thereof to the owner or by deposit in the United States m ail in a sealed envelope, postage prepaid, addressed to the owner as shown on the last equalized assessment roll. Service by mail shall be deemed to have been completed at the time of deposit in the U.S. mail. The failure of any owner to receive such notic e shall not affect in any manner the validity of any of the proceedings taken thereunder. Proof of giving notice may be made by an affidavit of any employee of the City which shows service in conformity with this Section. Building and Fire Life Safety Comm ission action, Nuisance Abatement Board action, Building Officer administrative action, other correspondence between the City and the building owner or building owner’s representative, or other evidence of knowledge of notification shall also be deemed as proof of giving notice. (d) Recordation. At the time the Building Officer serves the aforementioned order, the Building Officer shall file with the Office of the County Recorder a certificate stating that the subject building is within the scope of this Ch apter. The certificate shall also state that the owner thereof has been ordered to structurally analyze the building and to 39 structurally alter it when the Building Officer determines the building is not in compliance with this Chapter. If the building is e ither demolished, found not to be within the scope of this Chapter, or is structurally capable of resisting minimum seismic forces required by this Chapter as a result of structural alterations or an analysis, the Building Officer shall file with the Offic e of the County Recorder a certificate terminating the status of the subject building as being classified within the scope of this Chapter. SECTION 4. Chapter 8.68 of the Santa Monica Municipal Code is hereby amended to read as follows: Chapter 8.68 Voluntary Seismic Retrofit Requirements for Cripple Walls and Sill Plate Anchorage in Single -Family Dwellings VOLUNTARY SEISMIC STRENGTHENING PROVISIONS FOR CRIPPLE WALLS AND SILL PLATE ANCHORAGE IN SINGLE -FAMILY DWELLINGS 8.68.010 Adoption Purpose . Appendix Chapter A3 of the California Existing Building Code 2016 Edition, entitled “Prescriptive Provisions for Seismic Strengthening Prov isions of Cripple Walls and Sill Plate Anchorage of Light, Wood -Frame Residential Buildings” which adopts by reference Appendix Chapter A3 of the International Existing Building Code, 2015 Edition, as published by the California Building Standards Commiss ion and the International Code Council, (excluding Sections A301), is hereby adopted as the Voluntary Seismic Retrofit Requirements for Cripple Walls and Sill Plate Anchorage in Single -Family Dwellings of the City of Santa Monica. 40 The provisions of this Chapter are intended to promote public safety and welfare by reducing the risk of earthquake -induced damage to existing wood -framed single -family dwellings. The requirements contained in this Chapter shall substantially improve the seismic performance of t hese buildings but will not necessarily prevent all earthquake - related damage. When fully followed, these standards will strengthen the portion of the structure that is most vulnerable to earthquake damage. Prior to 1960, many wood frame dwellings were bui lt with raised wood floors supported by short wood stud walls known as cripple walls. These cripple walls are typically braced with weaker seismic materials such as portland cement plaster or horizontal wood siding. In addition, earlier building codes did not require wood frame buildings to be bolted to their foundations. Recent earthquakes of moderate magnitude have shown that if a building has weak cripple walls or is unbolted, it may fall off its foundation. Fallen buildings have collapsed, caught fire o r needed extensive repairs to restore their occupancy. 8.68.020 Purpose Scope . The provisions of this Chapter is intended to promote the safety and welfare of occupants in single -family dwellings by reducing the risk of earthquake -induced damage to existing wood -framed structures. The standards contained in this Chapter are intended to substantially improve the seismic performance of these buildings but will not necessarily prevent all earthquake -related damage. When fully followed, these standards will strengthen the portion of the structure that is most vulnerable to earthquake damage. Prior to 1960, many wood frame dwellings were built with raised wood floors supported by short wood stud walls known as cripple walls. These cripple walls are 41 typically braced with weaker seismic materials such as portland cement plaster or horizontal wood siding. In addition, earlier building codes did not require wood frame buil dings to be bolted to their foundations. Recent earthquakes of moderate magnitude have shown that if a building has weak cripple walls or is unbolted, it may fall off its foundation. Fallen buildings have collapsed, caught fire or needed extensive repairs to restore their occupancy. Owners of any light wood -frame single -family dwellings, which contain one or more of the following structural weaknesses, are encouraged to seismically retrofit their buildings pursuant to the provisions of this Chapter: (1) Si ll plates or floorframing that are supported directly on the ground without an approved foundation system. (2) Perimeter foundation system that is constructed only of wood posts supported on isolated pad footings. (3) Perimeter foundation system that is no t continuous at locations other than existing single -story exterior walls not exceeding ten feet (3,084 mm) in length forming an extension of floor area beyond the line of an existing continuous perimeter foundation or at porches, storage rooms and similar spaces not containing fuel -burning appliances. (4) Perimeter foundation system that is constructed of unreinforced masonry. (5) Sill plates that are not connected to the foundation or sill plate that are connected with less than what is required by the Bu ilding Code. (6) Floor framing members that are supported directly on an approved foundation system without a sill plate and are not connected to the foundation or are connected with less than what is required by the Building Code. 42 (7) Cripple walls that a re not braced in accordance with the requirements of this Chapter and Table 8.68 -A or cripple walls not braced with diagonal sheathing or wood structural panels in accordance with the Building Code. (8) Cripple walls or sill plates that are not connected t o the floor diaphragm above or are connected with less than what is required by the Building Code. 8.68.030 Scope and Applicability Definitions . Owners of any light wood -frame single -family dwellings, which contain one or more of the following structural weaknesses, are encouraged to seismically retrofit their buildings pursuant to the provisions of this Chapter: (1) Sill plates or floor framing that are supported dir ectly on the ground without an approved foundation system. (2) Perimeter foundation system that is constructed only of wood posts supported on isolated pad footings. (3) Perimeter foundation system that is not continuous at locations other than existing si ngle -story exterior walls not exceeding ten feet (3,084 mm) in length forming an extension of floor area beyond the line of an existing continuous perimeter foundation or at porches, storage rooms and similar spaces not containing fuel -burning appliances. (4) Perimeter foundation system that is constructed of unreinforced masonry. (5) Sill plates that are not connected to the foundation or sill plate that are connected with less than what is required by the California Building Code. (6) Floor framing member s that are supported directly on an approved foundation system without a sill plate and are not connected to the foundation or are connected with less than what is required by the California Building Code. 43 (7) Cripple walls that are not braced in accordanc e with the requirements of this Chapter or cripple walls not braced with diagonal sheathing or wood structural panels in accordance with the California Building Code. (8) Cripple walls or sill plates that are not connected to the floor diaphragm above or a re connected with less than what is required by the California Building Code. For the purpose of this Chapter, in addition to the applicable definitions in the Building Code, certain additional terms are defined as follows: Adhesive anchor is a fastener placed in hardened concrete or masonry that derives its holding strength from a chemical adhesive compound placed between the wall of the hole and the embedded portion of the anchor. Anchor side plate is a metal plate or plates used to conne ct a sill plate to the side of a concrete or masonry stem wall. Building Code is the Building Code of the City of Santa Monica. Cripple wall is a wood -framed stud wall extending from the top of the foundation to the underside of the lowest floor framing. E xpansion anchor is a mechanical fastener placed in hardened concrete or assembled masonry, designed to expand in a self -drilled or predrilled hole of a specified size and engage the sides of the hole in one or more locations to develop shear and/or tension resistance to applied loads without grout, adhesive or drypack. Perimeter foundation is a foundation system which is located under the exterior walls of a building. 44 Snug -tight is as tight as an individual can torque a nut on a bolt by hand using a wrench with a ten -inch (254 mm) long handle and the point at which the full surface of the plate washer is contacting the wood member and slightly indents the wood. Unreinforced masonry includes adobe, burned clay, concrete or sand -lime brick, hollow clay or conc rete block, hollow clay tile, rubble, cut stone and unburned clay masonry walls. 8.68.040 General strengthening requirements. (a) Scope. The structural weaknesses noted in Section 8.68.020 shall be strengthened in accordance with the requirements of this Chapter. Strengthening work may include both new construction and alteration of existing construction. Except as provided herein, all str engthening work and materials shall comply with the applicable provisions of the Building Code. Alternate methods of strengthening shall be allowed provided such systems are designed by an engineer or architect and approved by the Building Officer. (b) Use of Prescriptive Provisions. The prescriptive provisions of this Chapter apply to light wood -frame Group R, Division 3 and Group R Division 1 Occupancies with no more than four dwelling units when they contain one or more of the structural weaknesses as sp ecified in Section 8.68.020 . The prescriptive provisions of this Chapter do not apply to the buildings or elements thereof, listed below. These buildings or elements require analysis in accordance with all the requirements of the Building Code. (1) Buildin gs with a lateral force resisting system using poles or columns embedded in the ground. 45 (2) Cripple walls that exceed four feet (1,234 mm) in height. (3) Buildings exceeding two stories in height and any two -story building with cripple wall studs exceeding fourteen inches (360 mm) in height. (4) Buildings where the Building Officer determines that conditions exist that are beyond the scope of the prescriptive requirements of this Chapter. The Building Officer shall prepare prescriptive construction details for use in strengthening work. These prescriptive details and the prescriptive provisions herein are not intended to be the only acceptable strengthening methods permitted. Alternate details and methods may be used when approved by the Building Officer. (c ) Engineered Designs. When analysis by an engineer or architect is required or provided for a building within the scope of this Chapter, such analysis shall be in accordance with all requirements of the Building Code except that the scope of the strengthen ing work shall be limited to the part of the load path from the connection of the first floor diaphragm to the foundation -soil interface. 8.68.050 Requirements applicable to engineered and prescriptive methods. (a) Condition of Existing Wood Materials. All existing wood materials which will be a part of the strengthening work shall be in a sound condition and free from defects which substantially reduce the ca pacity of the member. Any wood material found to contain fungus infection shall be removed and replaced with new material. Any wood material found to be infested with insects or to have been infested shall be strengthened or replaced with new materials to provide a net dimension of sound wood at least equal to its undamaged original dimension. 46 (b) Floor Joists Not Parallel to Foundations. Floor joists framed perpendicular or at an angle to perimeter foundations shall be restrained by either an existing nomi nal two -inch (51 mm) wide continuous rim joist or by nominal two -inch (51 mm) wide full depth blocking between alternate joists in one - and two -story buildings, and between each joist in three -story buildings. Blocking for multistory buildings must occur a t each joist space above a braced cripple wall panel. Existing connections at the top edge of an existing rim joist or blocking need not be verified. The bottom edge connection to either the foundation sill plate or top plate of a cripple wall shall be ver ified unless a supplemental connection is provided. The minimum existing bottom edge connection shall consist of 8d toe nails spaced six inches (152 mm) apart for a continuous rim joist or three 8d toe nails per block. When this minimum bottom edge connect ion is not present, or is not verified, a supplemental connection shall be provided in accordance with subsection (d) of this section. When an existing continuous rim joist or the minimum existing blocking does not occur, new one and one -eighths inch (29 m m) wood structural panel blocking installed tightly between floor joists and nailed with 10d common nails at four inches on center to the sill or wall top plate shall be provided at the inside face of the cripple wall. In lieu of one and one -eighths inch (29 mm) wood structural panel blocking, tight fitting, full or near full depth two inches nominal width (51 mm) lumber blocking shall be allowed provided it does not split during installation. New blocking may be omitted where it will interfere with vents o r plumbing that penetrates the wall. (c) Floor Joists Parallel to Foundations. Where existing floor joists are parallel to the perimeter foundations, the end joist shall be located over the foundation and, except 47 for required ventilation openings, shall be continuous and in continuous contact with any existing foundation sill plate or top plate of the cripple wall. Existing connections at the top edge connection of the end joist need not be verified; however, the bottom edge connection to either the foundat ion sill plate or the top plate of a cripple wall shall be verified unless a supplemental connection is provided. The minimum bottom edge connection shall be 8d toe nails spaced six inches (152 mm) apart. If this minimum bottom edge connection is not prese nt or is not verified, a supplemental connection shall be provided in accordance with subsection (d) of this Section. (d) Supplemental Connections. Supplemental connections shall provide sufficient strength to transfer the seismic forces originating in the structure above to the cripple wall, sill plate or foundation below. Framing anchors of minimum twenty gauge steel and twelve approved fasteners may be considered to meet this requirement when spaced twenty -four inches (813 mm) on center for one -story bui ldings and sixteen inches (610 mm) on center for two -story buildings. Supplemental connections for three -story buildings shall be spaced as required by analysis in accordance with all the requirements of the Building Code. Exception: A supplemental connect ion is not required when: (1) The structural wood panel sheathing extends from the sill plate to the rim joist or blocking above. (2) The floor sheathing is nailed directly into the sill or top plate of the cripple wall. (e) Single Top Plate Ties. When a s ingle top plate exists in the cripple wall, all end joints in the top plate shall be tied. Ties shall be connected to each end of the discontinuous top plate and shall be equal to one of the following: 48 (1) Three -inch by six -inch (76mm by 152 mm) by 0.036 -i nch -thick (0.9 mm) galvanized steel and nailed with six 8d nails at each end. (2) One and one -half inches (38 mm) by twelve -inch (305 mm) by 0.058 inches (1.47 mm) galvanized steel nailed with six 16d nails at each end. (3) Two -inch by four -inch by twelve -inch wood blocking nailed with six 16d nails at each end. 8.68.060 Foundations. (a) New Perimeter Foundations. New perimeter foundat ions shall be provided for structures with the structural weaknesses noted in subsections 1 and 2 of Section 8.68.020 . Soil investigations or geotechnical studies are not required for this work unless the building shows signs of excessive settlement or movement or is located in a special study zone as designated by the City of Santa Monica or State of California. (b) Foundation Evaluation by Engineer or Architect. Partial perimeter foundations or unreinforced masonry foundations shall be evaluated by an engineer or architect for the force levels of the Building Code. Test reports or other substantiating data to determine existing foundation material strengths shall be submitted for review. When approved by the Building Officer, these foundation systems ma y be strengthened in accordance with the recommendations included with the evaluation in lieu of being replaced. Exception: When approved by the Building Officer, testing of existing foundations to determine material strengths shall not be required when a new non -perimeter foundation system is installed to resist all lateral forces as required in Section 8.68.040 (a) of the Municipal Code. 49 (c) Details for New Perimeter Foundations. All new perimeter foundations shall be continuous and constructed according t o the standards for new buildings. Exceptions: (1) When approved by the Building Officer, the existing clearance between existing floor joists or girders and existing grade below the floor need not comply with the Building Code. This exception shall not be permitted when buildings are raised and relocated on new foundations. (2) When approved by the Building Officer, and when designed by an engineer or architect, partial perimeter foundations may be used in lieu of a continuous perimeter foundation when the new nonperimeter foundation system is installed to resist all lateral forces as required in Section 8.68.040 (a) of the Municipal Code. 8.68.070 Foundation sill plate a nchorage. (a) Existing Perimeter Foundations. When the building has an existing continuous perimeter foundation, all perimeter wall sill plates shall be connected to the foundation in accordance with Table 8.68 -A and this Section. Anchors shall be installed with the plate washer installed between the nut and the sill plate. The nut shall be tightened to a snug -tight condition after curing is complete for adhesive anchors and after expansion wedge engagement for expansion anchors. The installation of nuts on all anchors shall be subject to verification by the Building Officer. Anchor side plates shall be permitted when conditions prevent anchor installation vertically through the sill plate. Anchor side plates shall be spaced as required for adhesive or expansion anchors but only one anchor side plate is required on individual pieces of sill plate less than thirty -two inches (813 mm) in length. Wood structural panel 50 shims shall be used on sill plates for single plate anchor side plates when the foundat ion stem wall is from three -sixteenths inch (4.8 mm) to three -fourths inch (19 mm) wider than the sill plate. The shim length shall extend a minimum of two inches (50.8 mm) past each end of the anchor side plate. Adjustable anchor side plates shall be used when the total thickness of the required shim exceeds three -fourths inch (19 mm). All anchor side plates which use lag or wood screws shall pre -drill the sill plate to prevent splitting as required by the Building Code. Lag or wood screws shall be install ed in the center of the thickness of the existing sill plate. Expansion anchors shall not be used in unreinforced masonry or concrete or masonry grout of poor quality. Adhesive anchors shall be required when expansion anchors will not tighten to the requir ed torque or their installation causes surface cracking of the foundation wall. (b) Placement of Anchors. Anchors shall be placed within twelve inches (305 mm), but not less than nine inches (229 mm), from the ends of sill plates and shall be placed near t he center of the stud space closest to the required spacing. New sill plates may be installed in pieces when necessary because of existing conditions. The minimum length of new sill plate pieces shall be thirty inches (762 mm). Exception: Where physical ob structions such as fireplaces, plumbing or heating ducts interfere with the placement of an anchor, the anchor shall be placed as close to the obstruction as possible, but not less than nine inches (229 mm) from the end of the plate. Center -to -center spaci ng of the anchors shall be reduced as necessary to provide the minimum total number of anchors required based on the full length of the wall. Center - to -center spacing shall not be less than twelve inches (305 mm). 51 (c) New Perimeter Foundations. Sill plates for new perimeter foundations shall be anchored as required by the Building Code. 8.68.080 Cripple wall bracing. (a) General. Unless analysis is provided by an engineer or architect, exterior cripple walls, not exceeding four feet (1,219 mm) in height, shall use the prescriptive bracing method listed below. Cripple walls more than four feet (1,219 mm) in height require analysis by an engineer or architect in accordance with the Building Code. (b) Sheathing Requirements. Wood structural panel sheathing shall not be less than fifteen -thirty -seconds -inch (12 mm) thick. When used, plywood panels shall be constructed of a minimum of four plies. All wood structural panels shall be nailed with 8d common nails spaced four inches (102 mm) on center at all edges and at twelve inches (305 mm) on center at each intermediate support. Nails shall be driven so that their head or crown is flush with the surface of the sheathing and shall penetrate the supporting member a minimum of one a nd one -half inch (38 mm). When a nail fractures the surface, it shall be left in place and not counted as part of the required nailing. A new 8d nail shall be located within two inches (51 mm) of the discounted nail and hand driven flush with the sheathing surface. All horizontal joints must occur over nominal two -inch by four -inch (51 mm by 102 mm) blocking installed with the nominal four -inch (102 mm) dimension against the face of the plywood. All vertical joints must occur over studs. Vertical joints at adjoining pieces of wood structural panels shall be centered on existing studs such that there is a minimum one -eighth inch (3.2 mm) between the panels. Nails shall be placed a minimum of one - half inch (12.7 mm) from the edges of the existing stud. When su ch edge distance cannot 52 be maintained because of the width of the existing stud, a new stud shall be added adjacent to the existing and connected with 16d common nails at eight inches (206 mm) on center. A minimum of three such nails shall be provided. (c) Distribution and Amount of Bracing. See Table 8.68 -A below for the distribution and amount of bracing required. Bracing for a building with two or more floor levels above cripple wall studs exceeding fourteen inches (356 mm) in height shall be designed in accordance with the Building Code. The length of the braced panel shall be at least two times the height of the cripple stud wall but not less than forty -eight inches (1,219 mm). All panels along a wall shall be nearly equal in length and shall be nearly equally spaced along the length of the wall. Braced panels at ends of walls shall be located as near the end as possible. When the minimum amount of bracing prescribed in Table 8.68 -A cannot be installed due to obstructions along any wall, the bracing must be designed by an architect or engineer. Exception: (1) Where physical obstructions such as fireplaces, plumbing or heating ducts interfere with the equal spacing requirement for cripple wall bracing, the bracing may be placed as close to the obstruction as possible, provided the total length of bracing required is not reduced. (2) Required lengths of braced panels may include underfloor ventilation openings when the height of the solid portion of the panel meets or exceeds seventy -five percent of the heig ht of the cripple stud wall provided the sheathing is properly fastened to framing members or blocking around the opening. 53 (3) For one - and two -story buildings, cripple walls less than twelve inches in height may be braced by two -inch nominal lumber nailed to the top plate with 16d common nails at four inches on center and connected to the sill plate with a supplemental connection as specified in Section 8.68.050 (d). Ventilation holes in such stud spaces shall not exceed one -inch in diameter. (d) Stud Space Ventilation. When bracing materials are installed on the interior face of studs forming an enclosed space between the new bracing and existing exterior finish, each braced stud space must be ventilated. Adequate ventilation and access for future inspection shall be pr ovided by drilling one two -inch to three -inch (51 mm to 76 mm) diameter round hole through the sheathing nearly centered between each stud at the top and bottom of the cripple wall. Such holes should be spaced a minimum of one - inch (25 mm) clear from the s ill or top plates. In stud spaces containing sill bolts, the hole shall be located on the centerline of the sill bolt but not closer than one -inch (25 mm) clear from the nailing edge of the sheathing. When existing blocking occurs within the stud space, ad ditional ventilation holes shall be placed above and below the blocking or the existing block shall be removed and a new nominal two -inch (51 mm) by four -inch (102 mm) block installed with the nominal four -inch (102 mm) dimension against the face of the pl ywood. For stud heights less than eighteen inches (457 mm) only one ventilation hole need be provided. Exception: When two -inch nominal bracing is used for one - and two -story buildings with cripple walls less than twelve inches in height, ventilation holes shall not exceed one - inch in diameter. 54 (e) Underfloor Ventilation. Existing underfloor ventilation shall not be reduced without providing equivalent new ventilation as close to the existing as possible. When a new continuous perimeter foundation system is being installed, ventilation shall be provided in accordance with the Building Code. 8.68.090 Quality assurance. (a) Inspection. All work shall be subject to inspec tion by the Building Officer including, but not limited to: (1) Placement and installation of new adhesive or expansion anchors or anchor side plates installed in existing foundations. (2) Placement of required blocking and framing anchors. (3) Installatio n and nailing of new cripple wall bracing. (b) Special Inspection. Unless required by the Building Officer or the architect or engineer of record, special inspection is not required for sill plate anchors installed in existing foundations regulated by the provisions of this Chapter. (c) Structural Observation. Structural observation is not required for work done under the prescriptive provisions of this Chapter. When construction documents for strengthening are prepared by an architect or engineer and alternate materials or methods are used, structural observation shall b e provided in accordance with the Building Code. Table 8.68 -A Sill Plate Anchorage and Cripple Wall Bracing 1,2,3 Number of Stories above Cripple Walls Minimum Sill Plate Connection and Maximum Spacing Amount of Wall Bracing 55 One story Adhesive or expansion anchors shall be one -half inch (12.7 mm) minimum diameter spaced at 6 feet (1829 mm) maximum center to center. Each end and not less than 50% of the wall length. Two story Adhesive or expansion anchors shall be one -half inch (12.7 mm) minimum di ameter spaced at four feet (1,219 mm) maximum center to center; or 5/8 inch (15.9 mm) spaced at 6 feet maximum center to center. Each end and not less than 70% of the wall length. 1 Plate washers for use with adhesive or expansion anchors shall be two -inch (51 mm) by two -inch (51 mm) by 3/16 -inch (4.8 mm) for 1/2 -inch (12.7 mm) diameter anchors and 2 -1/2 -inch (64 mm) by 2 -1/2 -inch (64 mm) by 1/4 -inch (6 mm) for 5/8 inch (15.9 mm) diameter anchors. 2 Existing sill plate anchor bolts shall be permitted to prov ide all or a portion of the sill plate connection requirement if: a. The anchor bolt is cast in concrete and in sound condition, and: b. The diameter size and maximum spacing meets or exceeds the requirements of Table 8.68 -A, and: c. A new plate washer conforming to footnote 1 is installed, and: d. The nut is connected to a snug tight condition. 3 Anchor side plates shall be permitted when conditions prevent anchor installation vertically through the sill plate. SECTION 5. Chapter 8.72 of the Santa Monica Municipal Code is hereby amended to read as follows: Chapter 8.72 Mandatory Seismic Retrofit Requirements for Soft, Weak or Open Front Walls in Light, Wood -Framed Buildings SEISMIC STRENGTHENING PROVISIONS FOR SOFT, WEAK OR OPEN FRONT WALLS IN LIGHT , WOOD - FRAMED BUILDINGS 8.72.010 Purpose. 56 The purpose of this Chapter is to promote public welfare and safety by reducing the risk of death or injury that may resul t from the effects of earthquakes on existing wood - frame multi -story buildings with soft, weak or open front walls (Soft Story Buildings). This Chapter creates minimum standards to mitigate hazards from structural deficiencies in soft story, weak or open f ront wall buildings. Adherence to these minimum standards will improve the performance of these buildings during earthquakes and reduce, but not necessarily prevent the loss of life, injury or earthquake -related damage. The purpose of this Chapter is to promote the public welfare and safety by reducing the risk of death or injury that may result from the effects of earthquakes on existing buildings of light wood -frame construction. This Chapter creates minimum standards t o strengthen the more vulnerable portions of these structures. When fully followed, these minimum standards will substantially improve the performance of these buildings but will not necessarily prevent all earthquake related damage. 8.72.020 Scope and Ap plicability . a) The provisions of this Chapter shall apply to all buildings of wood -frame construction, or wood -frame portions thereof, where: 1. The structure was built under building code standards enacted before November 10, 1980 ; and 2. The ground floor portion of the structure contains parking or other similar open floor space that causes soft, weak or open -front wall lines, and there exists one or more stories abo ve. b) Buildings described in subsection (a) have completed all required seismic retrofit work , with a lateral load resisting analysis and structural design plans, and 57 obtained valid final approval from the City of Santa Monica prior to the adoption of this Ordinance, are exempt from the requirements this Chapter , except that : 1. Buildings with pole structures supporting the soft, weak or open front walls shall be subject to this Chapter regardless of previous retrofit status; 2. Build ings of three or more stories having horizontal structural irregularities of Type 2, 3, 4, or 5 listed in ASEC 7 -10 “Horizontal Structural Irregularities ” Table 12.3 -1, shall be subject to this Chapter regardless of previous retrofit status. c) An owner of an y buildings within the scope of this Chapter shall demonstrate compliance with the mandatory seismic retrofit requirements of this Chapter, as set forth in Section 8.72.050, consistent with the time limits set forth in this Chapter. The provisions of this Chapter shall apply to all existing wood frame buildings or portions thereof designed using the Building Code in effect before December 12, 1995 where: (1) The ground floor portion of the wood frame structure contains parking or other similar open floor or basement space that causes soft, weak, or open front wall lines as defined in this Chapter and there exists one or more levels above; or (2) The walls of any story or basement of wood construction are laterally braced with nonconforming structural materia ls as defined in this Chapter and there exists two or more levels above. Buildings designated as historically or architecturally significant landmarks on national, State or local historical registers shall also comply with the provisions of this Chapter. A t the Building Officer’s discretion, modifications to the standards set forth in 58 this Chapter may be permitted when such modifications are consistent with the provisions of the State Historical Building Code. 8.72.030 Definitions. ASCE 7 -10 (March 7, 2013) is a standards publication by the American Society of Civil Engineer entitled “Minimum Design Loads for Buildings and Other Structures.” It provides requirements for general structural design. This publication is referenced in Chapter 35 of the California Building Code. Cripple Wall is a wood -framed stud wall extending from the top of the foundation wall to the underside of the lowest floor framing of the building. Ground Floor is any floor within the wood -frame portion of a building whose elevation is immediately accessible from an adjacent grade by vehicles or pedestrians. The ground floor portion of the structure does not include any floor that is completely below adjacent grades. Open -Front Wall Line is an exterior wall line, without vertical elements of the lateral force -resisting system, which requires tributary seismic forces to be resisted by diaphragm rotation o r excessive cantilever beyond parallel lines of shear walls. Diaphragms that cantilever more than 25 percent of the distance between lines of lateral force resisting elements from which the diaphragm cantilevers shall be considered excessive. Exterior exit balconies of six feet or less in width shall not be considered excessive cantilevers. Soft Wall Line is a wall line, the lateral stiffness of which is less than what is required by story drift limitations or deformation compatibility requirements of this Chapter. In lieu of the engineering analysis required by this Chapter to determine whether 59 a wall line's lateral stiffness is less than the aforementioned story drift limitations or deformation compatibility requirements, a soft wall line may be defined a s a wall line in a story where the wall stiffness is less than 70 percent of the stiffness of the exterior wall above for the direction under consideration. Story is as defined in the California Building Code, but includes any basement or underfloor space of a building with cripple walls exceeding four feet in height. Story Strength is the total strength of all seismic -resisting elements sharing the same story shear in the direction under consideration. Wall Line is any length of a wall along a principal axis of the building used to provide resistance to lateral loads. Weak Wall Line is a wall line at the ground floor where the wall strength is less than 80 percent of the strength of the wall above in the direction under consideration. Notwithstanding th e applicable definitions, symbols and notations in the Building Code, the following definitions shall apply for the purposes of this Chapter: Aspect ratio is the ratio of the height of a wall section to its width. Building Code is the Building Code of the City of Santa Monica. Cripple wall is a wood -framed stud wall extending from the top of the foundation wall to the underside of the lowest floor framing. Date of engineering report submittal is either that date upon which the r eport was due to be submitted to the City, or the date of actual submittal to the city, whichever is earlier. Expansion anchor is an approved mechanical fastener placed in hardened concrete, designed to expand in a self -drilled or pre -drilled hole of a spe cified size and 60 engage the sides of the hole in one or more locations to develop shear and/or tension resistance to applied loads without grout, adhesive or drypack. Ground floor is any floor within the wood frame portion of a building whose elevation is i mmediately accessible from an adjacent grade by vehicles or pedestrians. The ground floor portion of the structure does not include any level that is completely below adjacent grades. Level is a story, basement, or underfloor space of a building with cripp le walls exceeding four feet in height. Nonconforming structural materials are wall bracing materials for seismic loads whose allowable shear value was reduced or whose maximum allowable aspect ratio was decreased since the original building construction. These methods or materials include, but are not limited to cement or gypsum plaster, gypsum wallboard, diagonal or let -in bracing, straight or diagonal wood sheathing, particle board and structural wood panels. Open front wall line is an exterior wall line without vertical elements of the lateral force resisting system which requires tributary seismic forces to be resisted by diaphragm rotation or excessive cantilever beyond parallel lines of shear walls. Diaphragms that cantilever more than twenty -five per cent of the distance between lines of lateral force resisting elements shall be considered excessive. Exterior exit balconies of six feet or less in width shall not be considered excessive cantilevers. Retrofit is an improvement of the lateral force resist ing system by alteration of existing structural elements or addition of new structural elements. Soft wall line is a wall line whose lateral stiffness is less than required by story drift limitations or deformation compatibility requirements of this Chapter. In lieu of 61 analysis, this may be defined as a wall line in a story where the story stiffness is less than se venty percent of the story above for the direction under consideration. Story strength is the total strength of all seismic resisting elements sharing the same story shear in the direction under consideration. Type I building is any wood frame building tha t must be usable in the event of an emergency, and shall include hospitals, police and fire stations and disaster recovery centers. Type II building is any wood frame building with one hundred or more occupants or any building with occupied square footage other than parking or storage on the first floor or level of the building. Type III building is any wood frame building with at least twenty but fewer than one hundred occupants. Type IV building is any wood frame building with fewer than twenty occupants. Wall line is any length of a wall along a principal axis of the building used to provide resistance to lateral loads. Parallel wall lines separated by less than four feet shall be considered one wall line for the distribution of loads. Weak wall line is a wall line laterally braced with nonconforming structural materials or a wall line in a story where the story strength is less than eighty percent of the story above in the direction under consideration. Wood frame building is any building whose basic stru ctural system is a bearing wall system and whose lateral -force -resisting system is mostly light framed walls with shear panels but may also consist, in lesser part, of braced frames, moment frames or cantilevered column elements. 62 8.72.040 General requirements. (a) The owner of each building within the scope of the Chapter shall cause an investigation of the existing construction and a structural analysis to be made of the building by a civil or structural engineer or architect licensed by the State of California, and if the building does not meet the minimum standards specified in this Chapter, the owner shall cause it to be structurally altered to conform to such st andards. (b) The owner of each building within the scope of this Chapter, which has been analyzed to demonstrate compliance or structurally altered to comply with the minimum earthquake standards in this Chapter, shall maintain such building in conformity with the requirements of this Chapter in effect at the time of such analysis or structural alteration. (c) Buildings within the scope of the Chapter may not be added to or structurally altered or otherwise remodeled without first complying with the provisi ons of this Chapter unless the Building Officer determines that the alterations are minor in nature. (d) Notwithstanding any other provisions of this Code to the contrary, it is unlawful for any person, firm or corporation to maintain, use or occupy any bu ilding within the scope of this Chapter which does not meet the minimum earthquake standards specified in this Chapter. This provision shall not apply if alteration or repair work has commenced to bring the building into compliance with requirements of thi s Chapter, and such work is proceeding in accordance with the time limits set forth in any order of the Building Officer or determination of the Nuisance Abatement Board. 8.72.050 Engineering A nalysis and D esign Demolition . 63 (a) Scope of analysis. This Chapter requires the alteration, repair, retrofit, replacement or addition of structural elements and their connections to meet the strength and stiffness requirements set forth in this Chapter, except as modified herein. The structural evaluation r equired by this Chapter shall analyze and identify structural deficiencies in accordance with ASCE 7 -10 . As part of the structural evaluation, the lateral -load -path analysis shall include the resisting elements and connections from the wood diaphragm immed iately above any soft, weak or open wall lines to the foundation. Stories above the weak wall line shall be considered in the analysis but need not be structurally strengthened . (b) Design b ase shear and design parameters. The design force in a given direction shall be 75% of the design base shear specified in the seismic provision of ASCE 7 -10 . The value of response modification coefficient, R, need not be less than 3.5, provided the strengthening systems are not cantilev ered column systems and the strengthened structure will not have vertical struc tural irregularities of either T ype 1a, 1b, 5a or 5b listed in ASCE 7 -10 , "Vertical Structural Irregularities” Table 12.3 -2 . (c) Lateral vertical systems. Strengthening systems with concrete walls or masonry walls, or steel braced frames shall not be permitted. (d) Horizontal structural irregularities in buildings with three or more stories. Structures with three or more stories having horizontal structural irregularities of eit her T ype 2, 3, 4, or 5 listed in ASCE 7 -10 , “Horizontal Structural Irregularities” Table 12.3 -1 , shall be altered to meet the additional requirements of those sections referenced in the table for the entire story with weak or open wall lines. 64 (e) Alternate analysis, base shear and design parameters. Alternate design methodologies that improve the whole first story seismic performance that are at least equivalent to those prescribed by this Chapter and that achieve the life safety objectives est ablished by this Chapter may be submitted to the City for alternative analysis for base shear and design parameters. (f) Additional anchorage requirements for buildings on hillsides. Where any portion of a building within the scope of this Chapter is const ructed on or into a slope steeper than one -unit vertical in three units horizontal (33 -percent slope), the lateral -force - resisting system, at and below the base level diaphragm, shall also be analyzed for the effects of concentrated lateral loads caused at the building base from the hillside conditions and comply with the provisions of the City of Santa Monica Building Code. (g) Story drift limitations. The calculated story drift for each retrofitted story shall not exceed the allowable deformation compatib le with all vertical load -resisting elements and 0.025 times the story height. The calculated story drift shall not be reduced by the effects of horizontal diaphragm stiffness, but shall be increased when these effects produce rotation. Drift calculations shall be in accordance with ASCE 7 -10 requirements. (h) Pole structures. The effects of rotation and soil stiffness shall be included in the calculated story drift where lateral loads are resisted by vertical elements whose required depth of embedment is determined by pole formulas. The coefficient of subgrade reaction used in deflection calculations shall be based on an approved geotechnical investigation conducted in accordance with approved geotechnical engineering reports. (i) P -Delta effect. The requ irements of the California Building Code shall apply, except as modified herein. All structural framing elements and their connections not 65 required by the design to be part of the lateral force resisting system shall be designed and detailed to be adequate to maintain support of design dead plus live loads when subject to the expected deformations caused by seismic forces. The stress analysis of cantilever columns shall use an effective length factor of 2.1 for the direction normal to the axis of the beam. (j) Ties, continuity and collectors. All parts of the structure included in the scope of analysis shall be interconnected and the connection shall be capable of resisting the seismic force created by the parts being connected as required per the California Bu ilding Code. An owner desiring to demolish a building must nevertheless comply with the strengthening provisions of this Code within the time allowed unless such owner receives permission to demolish the building prior to the time limits set forth in this Chapter for the filing of a permit and the submitting of plans to the Building Officer. Such an owner shall submit a demolition permit application to the Building Officer and shall meet all of the requirements for demolition imposed by this Code, includin g but not limited to those requirements set forth in Section 9.04.10.16.010 of this Code, before such a demolition shall be permitted. Nothing in this Chapter shall be deemed to relieve a building owner of meeting the requirements for demolition of a build ing imposed by any other applicable law or regulation. 8.72.060 Time limits for compliance Time period for compliance . The owner of any building covered by this Chapter shall comply with the following time limits. Action by Building Owner Time Limits from Date of Service of Order 66 Structural Evaluation Report 2 Years or 24 Months Application for Building Permit and Submission of Plans 3 Years or 36 Months Final Approval 6 Years or 72 Months (a) Engineering Report. Within one hundred twenty days of the date of notice to the owner by the City, the owner of any building subject to the provisions of this Chapter shall submit an engineering report to the Building and Safety Division. The report shall demonstrate whether the structure conforms to the earthquake design provisions contained in this Chapter. (b) Plan, Permits and Construction. If the report concludes the structure does not comply with the provisions of this Chapter, the structure shall be strengthened to com ply with the standards of this Chapter within the time periods shown in Table 8.72 -A below. Table 8.72 -A Time Limits for Owner Building Type File for Permit/Submit Plans Commence Construction Complete Construction I 60 days from date of engineering report submittal 150 days from date of engineering report submittal 1 year from date of engineering report submittal II 180 days from date of engineering report submittal 270 days from date of engineering report submittal 3 years from date of engineering report submittal 67 III 1 1/2 years from date of engineering report submittal 1 year 8 months from date of engineering report submittal 3 years from date of engineering report submittal IV 2 years 5 months from date of engineering report submittal 2 years 8 month s from date of engineering report submittal 4 years from date of engineering report submittal 8.72.070 Administration. (a) Building Classification. The Building Officer shall determine the occupant load and classification of building type. The occupant load shall be determined in accordance with the Building Code and shall include the entire building plus the occupant load of any adjacent building th at interconnects with the subject building or uses the subject building for exiting purposes. (b) Contents of Order. When the Building Officer determines that a building is within the scope of this Chapter, the Building Officer shall issue an order as prov ided herein. The order shall specify that the building has been determined by the Building Officer to be within the scope of this Chapter and, therefore, is required to meet the seismic strengthening provisions of this Chapter. The order shall specify the building type classification and shall set forth the owner’s alternatives and time limits for compliance. (c) Service of Order. The order shall be in writing and may be given either by personal delivery thereof to the owner or by deposit in the United Stat es mail in a sealed envelope, postage prepaid, addressed to the owner as shown on the last equalized 68 assessment roll. Service by mail shall be deemed to have been completed at the time of deposit in the U.S. mail. The failure of any owner to receive such n otice shall not affect in any manner the validity of any of the proceedings taken thereunder. Proof of giving notice may be made by an affidavit of any employee of the City which shows service in conformity with this Section. Building and Fire Life Safety Commission action, Nuisance Abatement Board action, Building Officer administrative action, other correspondence between the City and the building owner or building owner’s representative, or other evidence of knowledge of notification shall also be deemed as proof of giving notice. (d) Recordation. At the time that the Building Officer serves the aforementioned order, the Building Officer shall file with the Office of the County Recorder a certificate stating that the subject building is within the scope o f this Chapter. The certificate shall also state that the owner thereof has been ordered to structurally analyze the building and to structurally alter it when the Building Officer determines the building is not in compliance with this Chapter. If the buil ding is either demolished, found not to be within the scope of this Chapter, or is structurally capable of resisting minimum seismic forces required by this Chapter as a result of structural alterations or an analysis, the Building Officer shall file with the Office of the County Recorder a certificate terminating the status of the subject building as being classified within the scope of this Chapter. 8.72.080 Analysis a nd design. (a) General. Every building within the scope of this Chapter shall be analyzed, designed and constructed in conformance with the Building Code except as modified 69 herein. No alteration of the existing lateral force -resisting or vertical load -c arrying system shall reduce the strength or stiffness of the existing structure. When any portion of a building within the scope of this Chapter is constructed on or into a slope steeper than one unit vertical in three units horizontal, the lateral -force - resisting system at and below the base level diaphragm shall also comply with the provisions of Chapter 8.20 of this Code. When the portion of the building that requires strengthening is limited to the underfloor area of the first floor and that area is used only as an uninhabited crawl space, strengthening requirements shall also compl y with the provisions of Chapter 8.68 of this Code. (b) Scope of Load Path. This Chapter requires the alteration, repair, replacement or addition of structural elements and their connections to meet the strength and stiffness requirements herein. The later al load path analysis shall include the resisting elements and connections from the wood diaphragm above any soft, weak or open front wall lines to the foundation soil interface or reinforced concrete slab or masonry wall supporting elements below. The lat eral load path analysis for added structural elements shall also include evaluation of the allowable soil bearing and lateral pressures in accordance with the Building Code. When an open front, weak or soft wall line exists due to parking at the ground level of a two -level building and the parking area is less than twenty percent of the ground floor level, then only the wall lines in the open, weak or soft directions of the enclosed parking area, need comply with the provisions of this Chapter. 70 (c) Desig n Base Shear. The design base shear in a given direction shall be equal to the base shear that the Building Code requires for new buildings. (d) Vertical Distribution of Forces. The total seismic force shall be distributed over the height of the structure in accordance with the Building Code except that distribution of force by story weight shall be permitted for two -story buildings. The value of R used in the design of any story shall be less than or equal to the value of R used in the given direction for the story above. (e) Weak Story Limitation. The structure shall not exceed thirty feet in height or two levels if the lower level strength is less than sixty -five percent of the story above. Existing walls shall be strengthened as required to comply with t his provision unless the weak level can resist a total lateral seismic force of three times the design force prescribed in subsection (c) of this Section. The story strength for each level of all other structures shall be a minimum of eighty percent of the story above. (f) Story Drift Limitation. The calculated story drift for each retrofitted level shall not exceed the allowable deformation compatible with all vertical load resisting elements and the story drift limitations of the Building Code. The calcul ated story drift shall not be reduced by the effects of horizontal diaphragm stiffness but shall be increased when these effects produce rotation. The effects of rotation and soil stiffness shall be included in the calculated story drift when lateral loads are resisted by vertical elements whose required depth of embedment based on the requirements of Section 1807.3 of the California Building Code . The coefficient of variation of subgrade reaction used in the deflection calculations shall 7 1 be provided from a n approved geotechnical engineering report or other approved methods. (g) PΔ Effects. The requirements of the Building Code shall apply except as modified herein. All framing elements not required by the design to be part of the lateral force resisting sys tem shall be investigated and shown to be adequate for vertical load carrying capacity when displaced three times the displacements resulting from the required lateral force. The stress analysis of cantilever columns shall use a buckling factor of 2.1 for the direction normal to the axis of the beam. (h) Ties and Continuity. All parts of the structure included in the scope of subsection (b) of this Section shall be interconnected and the connection shall be capable of resisting the seismic force created by the parts being connected. Any smaller portion of a building shall be tied to the remainder of the building with elements having a minimum strength equal to one -fifth of the tributary dead load of the smaller portion. A positive connection for resisting a horizontal force acting parallel to the member shall be provided for each beam, girder or truss included in the lateral load path. This force shall not be less than one -tenth of the combined tributary dead and live loads or as required by the lateral load path transfer, whichever is greater. (i) Collector Elements. Collector elements shall be provided that can transfer the seismic forces originating in other portions of the building to the elements within the scope of subsection (b) of this Section that pro vide resistance to those forces. (j) Horizontal Diaphragms. The analysis of shear demand or capacity of an existing plywood or diagonally sheathed horizontal diaphragm need not be investigated unless the diaphragm is required to transfer lateral forces fro m the lateral resisting 72 elements above the diaphragm to other lateral resisting elements below the diaphragm due to offset in placement of the elements. Wood diaphragms in structures that support floors or roofs above shall not be allowed to transmit later al forces by rotation or cantilever. However, rotational effects shall be accounted for when unsymmetric wall stiffness increases shear demands. Exception: Diaphragms that cantilever twenty -five percent or less of the distance between lines of lateral load resisting elements from which the diaphragm cantilevers may transmit their shears by cantilever provided that rotational effects on shear walls parallel and perpendicular to the load are accounted for. (k) Shear Walls. Shear walls shall have sufficient strength and stiffness to resist the tributary seismic loads and shall conform to the special requirements of this Section. (l) Gypsum or Plaster Products. Gypsum or plaster products shall not be used to provide lateral r esistance. (m)Wood Structural Panels. Shear walls sheathed with wood structural panels may be used to resist horizontal forces that do not exceed the allowable shear values and story drift limitations of the Building Code. Openings are permitted in shear walls if they do not exceed fifty percent of the height or width of the shear wall. The remaining portion of the shear wall shall be strengthened for the transfer and increase of all shearing forces caused by the opening. The resulting shear wall shall be analyzed as a mosaic of shear resisting elements. Blocking and steel strapping shall be employed at the corners of the opening to transfer forces from discontinuous boundary elements into adjoining panel elements. 73 The effect of openings on the stiffness of the shear wall shall be demonstrated to comply with the story drift limitations of the Building Code. The stiffness shall be calculated using the properties of the different shear elements making up the shear wall or it shall be demonstrated by approved t esting. When shear walls cannot be made to conform to the requirements of this Section because of existing openings, the openings shall be relocated or reduced in width to meet the strength and stiffness requirements of the lateral loads. Relocated and alt ered openings shall comply with the emergency escape and rescue requirements of the Building Code. Relocated and altered openings shall comply with the light and ventilation requirements for residential occupancies unless otherwise approved by the Building Officer. (n) Wood Species of Framing Members. Allowable shear values for wood structural panels shall consider the species of the framing members. When the allowable shear values are based on douglas fir -larch framing members and framing members are const ructed of other species of lumber, the allowable shear values shall be multiplied by the following factors: 0.82 for species with specific gravities greater than or equal to 0.42 but less than 0.49, and 0.65 for species with specific gravities less than 0.42. Redwood shall use 0.65 and hem fir shall use 0.82 unless otherwise approved. (o) Mechanical Penetrations. Mechanical penetrations in shear walls shall be accounted for in the design or the shear wall shall be analyzed as two separate walls on each side of the penetration. (p) Substitution for Three -Inch Nominal Width Framing Members. Double two - inch nominal width framing members shall be permitted in lieu of any required three -inch 74 nominal width framing member when the existing and new framing member ar e of equal dimensions, are connected as required to transfer the in -plane shear between them and the sheathing for the shear wall is equally fastened between them. (q) Hold Down Connectors. Expansion anchors that provide tension strength by friction resist ance shall not be used to connect hold down devices to existing concrete or masonry elements. Expansion anchors shall be permitted to provide tension strength by bearing. The required depth of embedment or edge distance for the anchor used in the hold down connector shall be provided in the concrete or masonry below any plain concrete slab unless satisfactory evidence is submitted to the Building Officer that shows that the concrete slab and footings are of monolithic construction. Bolted hold down connecto rs shall be pre -loaded to reduce slippage of the connector. Pre -loading shall consist of tightening the nut on the tension anchor after the placement but before the tightening of the shear bolts in the panel flange member. The tension anchor shall be tight ened until the shear bolts are in firm contact with the edge of the hole nearest the direction of the tension anchor. Hold down connectors with self - jigging bolt standoffs shall be installed in a manner to permit pre -loading. Deformation of hold down conne ctors at ultimate loads shall be compatible with adjoining elements and shall be verified by approved testing. 8.72.090 Materials of construction. (a) New Materials. All materials approved by the Building Code, including their appropriate allowable stresses and minimum aspect ratios, shall be permitted to meet the requirements of this Chapter. 75 (b) Allowable Foundation and Lateral Pressures. Allowable foundation and la teral pressures shall be permitted to use the values from the Building Code. The coefficient of variation of subgrade reaction shall be established by an approved geotechnical engineering report or other approved methods when used in the deflection calcula tions of embedded vertical elements as required in Section 8.72.080 (f). (c) Existing Materials. All existing materials shall be in sound condition and constructed in conformance to the Building Code before they can be used to resist the lateral loads presc ribed in this Chapter. The verification of existing material conditions and their conformance to these requirements, shall be made by physical observation reports, material testing or record drawings as determined by the structural designer and approved by the Building Officer. (d) Wood Structural Panel Shear Walls. (1) Allowable Nail Slip Values. When the required drift calculations of Section 8.72.080 (f) rely on the lower slip values for common nails or surfaced dry lumber, their use in construction shall be verified by exposure. The use of box nails and unseasoned lumber may be assumed without exposure. The verification of surfaced dry lumber shall be by identification conforming to the Building Code. (2) Reduction for Clipped Nail Heads. When exposed nai ls do not meet the nominal head sizes required for hand driven nails in the Building Code, the allowable shear capacity for shear walls sheathed with wood structural panels shall be reduced. Allowable shear values for sheathing nailed with clipped nail hea ds shall be equal to sheathing fastened with casing heads in the Building Code. 76 (3) Plywood Panel Construction. When verification of the existing plywood materials is by use of record drawings alone, the panel construction for plywood shall be assumed to be of three plies. (4) Framing Members of Other Species. When verification of the existing wood material is by u se of record drawings, the allowable shear capacity shall be multiplied by the reduction factor of 0.82 for buildings built on or after 1960. Buildings built before this period shall use the reduction factor 0.65. When verification of the existing wood mat erial is by identification in conformance to the Building Code, the allowable shear capacity in the Building Code may be used. (e) Lumber. When the existing dimensioned lumber is not identified in conformance to the Building Code, the allowable stresses fo r lumber shall be permitted for the structural elements specified below. Posts and beams Douglas Fir -larch No. 1 Joists and rafters Douglas Fir -larch No. 2 Studs, blocking Hem Fir Stud. (f) Structural Steel. All existing structural steel shall be permitted to use the allowable stresses for Grade A36. Existing pipe or tube columns shall be assumed to be of minimum wall thickness unless verified by testing or exposure. (g) Strength of Concrete. All existing con crete footings shall be permitted to use the allowable stresses for plain concrete with a compressive strength of two thousand psi. The strength of existing concrete with a record compressive strength greater than two thousand psi shall be verified by test ing, record drawings or records of the enforcement agency. 77 (h) Existing Sill Plate Anchorage. Existing cast -in -place anchor bolts shall be permitted to use the allowable service loads for bolts with proper embedment when used for shear resistance to lateral loads and provided with plate washers as required in the Building Code. 8.72.100 Required information on plans. (a) General. The plans shall show all necessary dimensions and materials for plan review and construction and shall accurately reflect the results of the engineering investigation and design. (b) Existing Construction. The plans shall show the existing diaphragm and s hear wall sheathing and framing materials, fastener type and spacing, diaphragm and shear wall connections, continuity ties, and collector elements. The plans shall also show the portion of the existing materials that needs verification during construction . (c) New Construction. (1) Foundation Plan Elements. The foundation plan shall include the size, type, location and spacing of all anchor bolts with the required depth of embedment, edge and end distance; the location and size of all columns for braced or moment frames; referenced details for the connection of braced or moment frames to their footing and referenced Sections for any grade beams and footings. (2) Framing Plan Elements. The framing plan shall include the width, location and material of shear walls; the width, location and material of frames; references on details for the column to beam connectors, beam to wall connections, and shear transfers at floor and roof diaphragms; and the required nailing and length for wall top plate splices. 78 (3) Shea r Wall Schedule, Notes and Details. Shear walls shall have a referenced schedule on the plans that includes the correct shear wall capacity in pounds per foot; the required fastener type, length, gauge and head size; and a complete specification for the sh eathing material and its thickness. The schedule shall also show the required location of three -inch nominal or double two -inch nominal edge members; the spacing of shear transfer elements such as framing anchors or added sill plate nails; the required hol d - down with its bolt, screw or nail sizes; and the dimensions, lumber grade and species of the attached framing member. Notes shall show required edge distance for fasteners on structural wood panels and framing members; required flush nailing at the plywo od surface; limits of mechanical penetrations; and the sill plate material assumed in the design. The limits of mechanical penetrations shall also be detailed showing the maximum notching and drilled hole sizes. (4) Quality Control and Assurance Requiremen ts. General notes shall show the requirements for material testing, special inspection, structural observation and the proper installation of newly added materials. 8.7 2.110 Quality assurance. (a) Structural Observation. All structures regulated by this Chapter require structural observation during construction. The owner shall employ the engineer or architect responsible for the structural design, or another engineer or architect designated by the engineer or architect r esponsible for the structural design, to perform structural observation as defined in the Building Code SECTION 6. Chapter 8.76 of the Santa Monica Municipal Code is hereby amended to read as follows: 79 Chapter 8.76 Mandatory Seismic Retrofit Requirements for Existing Welded Steel Moment Frame Structures SEISMIC STRENGTHENING PROVISIONS FOR EXISTING WELDED STEEL MOMENT FRAME STRUCTURES 8.76.010 Purpose. The provisions of this Chapter are intended to promote the public welfare and safety by reducing the risk of death or injury that may result from the effects of earthquakes on Existing Welded Steel Moment Frame Buildings. The welded connections and non -ductili ty of the steel connecting elements introduce poor performance of these buildings in seismic events. The deficiencies in the lateral force resisting system beam - column connections could experience damage and possible connection failures. This Chapter cre ates minimum standards intended to improve the performance of these buildings during earthquakes and reduce, but not necessarily prevent , the loss of life, injury or earthquake -related damage. The purpose of this Chapter is to promote public safety and we lfare by reducing the risk of death or injury that may result from the effects of earthquakes on welded steel moment frame structures. 8.76.020 Scope and Applicability . (a) The provisions of this Chapter shall apply to any building utilizing a Welded Steel Moment Frames that was built under building code standards enacted before January 1, 1996 . (b) Buildings described in subsection (a) above that have completed all req uired seismic retrofit work , with a lateral load resisting analysis and structural design 80 plans, and obtained valid final approval from the City of Santa Monica prior to the adoption of this Ordinance, are exempt from the requirements this Chapter. (c) An owne r of any buildings within the scope of this Chapter shall demonstrate compliance with the mandatory seismic retrofit requirements of this Chapter, as set forth in Section 8.76.050, consistent with the time limits set forth in this Chapter. (d) Welded steel mom ent frames in existing unreinforced masonry buildings or in soft story buildings are exempt from the requirements of this Chapter. The provisions of this Chapter shall apply to all buildings that were designed under building codes in effect prior to December 12, 1995, or built with building permits issued prior to December 12, 1996 and said buildings are welded steel moment frame structures as defined herein. Buildings designated as historically or architecturally significant landmarks on national, st ate or local historical registers shall also comply with the provisions of this Chapter. At the Building Officer’s discretion, modifications to the standards set forth in this Chapter may be permitted when such modifications are consistent with the provisi ons of the State Historical Building Code. Seismic strengthening in place prior to the effective date of the ordinance codified in this Chapter shall be evaluated according to the provisions of this Chapter and modified if deemed necessary by the Building Officer. 8.76.030 Definitions. ASCE 41 -13 (2014 Edition) is a standards publication by the American Society of Civil Engineer entitled “Seismic Evaluation and Retrof it of Existing Buildings” and describes deficiency –based and systematic procedures to evaluate and retrofit existing 81 buildings to withstand the effects of earthquakes. This publication is referenced in Chapter 35 of the California Building Code. Load path deficiency occurs when the structure does not contain a complete, well defined load path, including structural elements and connections, that serves to transfer the inertial forces associated with the mass of all elements of the building to the foundation . Steel moment frame is a frame capable of resisting horizontal forces caused by the steel members (beams and column) and joints resisting forces primarily caused by flexure. For purposes of this Chapter, the applicable definitions in the Building Code and the following shall apply: Building Code is the Building Code of the City of Santa Monica. Commenced construction is construction pursuant to a valid building permit which has progressed to the point that one of the called inspections as required by th e Building Officer has been made and the work for which the inspection has been called has been judged by the Building Officer to be substantial and has been approved by the Building Officer. Date of engineering report submittal is either that date upon wh ich the report was due to be submitted to the City, or the date of actual submittal to the City, whichever is earlier. Type I building is any welded steel moment frame structure that must be usable in the event of an emergency, and shall include hospitals, police and fire stations and disaster recovery centers. 82 Type II building is any welded steel moment frame structure with one hundred or more occupants. Type III building is any welded steel moment frame structure with at least twenty but fewer than one hu ndred occupants. Type IV building is any welded steel moment frame structure with fewer than twenty occupants. Welded steel moment frame structure is any building whose primary lateral - force -resisting system is either a special -moment -resisting frame or or dinary resisting frame constructed of steel with fully welded connections or connections which are partially welded and partially bolted. 8.76.040 Compliance requiremen ts General requirements . The structural evaluation, structural analysis report, and structural design plans for the seismic strengthening and retrofit for Welded Steel Moment Frame buildings shall be conducted by a State of California licensed civil or structural engineer, or a St ate of California registered architect. For Welded Steel Moment Frame buildings over 55 feet in height as described by Section 8.44.090 of the Santa Monica Municipal Code, the structural evaluation, structural analysis report, and structural design plans shall be conducted by a State of California licensed structural engineer. Plans and associated documents shall bear the seal and signature of the design professional. (a) The owner of each building within the scope of the Chapter shall cause an investigation of the existing construction and a structural analysis to be made of the 83 building by a structural engineer licensed by the State of California, and if the building does not meet the minimum standards specified in this Chapter, the owner shall cause it to be structurally altered to conform to such standards. (b) The owner of each building within the scope of this Chapter, which has been analyzed to demonstrate compliance or structurally altered to comply with the minimum earthquake standards in this Chapter, shall maintain such building in conformity with the requirements of this Chapter in effect at the time of such analysis or structural alteration. (c) Buildings within the scope of the Chapter may not be added to or structurally altered or ot herwise remodeled without first complying with the provisions of this Chapter unless the Building Officer determines that the alterations are minor in nature. (d) Notwithstanding any other provisions of this Code to the contrary, it is unlawful for any per son, firm or corporation to maintain, use or occupy any building within the scope of this Chapter which does not meet the minimum earthquake standards specified in this Chapter within any of the time periods established. This provision shall not apply if a lteration or repair work has commenced to bring the building into compliance with requirements of this Chapter, and such work is proceeding in accordance with the time limits set forth in any order of the Building Officer or determination of the Nuisance A batement Board. 8.76.050 Engineering analysis and design Demolition . (a) Evaluation, analysis and engineering report. This Chapter requires the alteration, repair, retrofit, replacement or addition of structural elements and their connections to meet the strength and stiffness requirements set forth in this Chapter, except as modified herein. The structural evaluation re quired by Section 8.58.0 3 0 shall 84 analyze and identify all structural deficiencies in accordance with ASCE 41 -13 . The engineering report, containing the required structural evaluation, shall further identify major deficiencies observed in the analysis of t he building including: deficient load path, weak or soft story conditions, horizontal or vertical irregularities. (b) Major deficiencies. Any of the major deficiencies described in 8.76.050(a) shall cause the building to be retrofitted. Retrofit work to mitigate the major deficiencies shall not impact the existing lateral load elements by increasing any demand -to -capacity ratio by more th an ten -percent unless the existing elements are shown to be capable of resisting the increased demand. The mitigation of the major deficiencies shall also not create additional structural deficiencies or make the existing structural deficiencies more seve re. (c) Advance analysis. The engineering report may show that the major deficiencies meet the requirements of ASCE 41 -13 by advanced analysis. (d) Structural analysis, design and evaluation . The building shall meet or exceed the structural performance l evel for the associate earthquake hazard levels based on Risk Category as defined in ASCE 41 -13 as follows: Risk Category Hazard Level 1 Hazard Level 2 I & II BSE -1E, S -3 BSE -2E, S -5 III & IV BSE -1E, S -2 BSE -2E, S -5 An owner desiring to demolish a building must nevertheless comply with the strengthening provisions of this Code within the time allowed unless such owner receives 85 permission to demolish the building prior to the time limits set forth in Section 8.76.060 f or the filing of a permit and the submitting of plans to the Building Officer. Such an owner shall submit a demolition permit application to the Building Officer and shall meet all of the requirements for demolition imposed by this Code, including but not limited to those requirements set forth in Section 9.04.10.16.010 of this Code, before such a demolition shall be permitted. Nothing in this Chapter shall be deemed to relieve a building owner of meeting the requirements for demolition of a building impose d by any other applicable law or regulation. 8.76.060 Time period for compliance. (a) Engineering Report. Within two hundred seventy -five days of the date of notice to the owner by the City, the owner of any welded steel frame structure shall submit to the Building and Safety Department an engineering evaluation report prepared by a California registered stru ctural engineer based upon an inspection of a representative sample of connections of the building (“structural report”). (b) Strengthening and Repair Requirements. If the structural report concludes that the building does not conform with approved standar ds and analysis, or if other significant damage is found in the inspection, the building shall be repaired to fully conform with the referenced standards within the time periods shown in Table 8.76 -A below. Table 8.76 -A Time Limits for Owner Building Type File for Permit/Submit Plans Commence Construction Complete Construction 86 I 60 days from date of engineering report submittal 150 days from date of engineering report submittal 1 year from date of engineering report submittal II 180 days from date of engineering report submittal 270 days from date of engineering report submittal 3 years from date of engineering report submittal III 1 1/2 years from date of engineering report submittal 1 year 8 months from date of engineering report submittal 3 years f rom date of engineering report submittal IV 2 years 5 months from date of engineering report submittal 2 years 8 months from date of engineering report submittal 4 years from date of engineering report submittal 8.76.070 Administration. (a) Building Classification. The Building Officer shall determine the occupant load and classification of building type. The occupant load shall be determined in accordance with the Building Code and shall include the entire building plus the occupant load of any adjacent building th at interconnects with the subject building or uses the subject building for exiting purposes. (b) Contents of Order. When the Building Officer determines that a building is within the scope of this Chapter, the Building Officer shall issue an order as prov ided herein. The order shall specify that the building has been determined by the Building Officer to be within the scope of this Chapter and, therefore, is required to meet the 87 seismic strengthening provisions of this Chapter. The order shall specify the building type classification and shall set forth the owner’s alternatives and time limits for compliance. (c) Service of Order. The order shall be in writing and may be given either by personal delivery thereof to the owner or by deposit in the United Stat es mail in a sealed envelope, postage prepaid, addressed to the owner as shown on the last equalized assessment roll. Service by mail shall be deemed to have been completed at the time of deposit in the U.S. mail. The failure of any owner to receive such n otice shall not affect in any manner the validity of any of the proceedings taken thereunder. Proof of giving notice may be made by an affidavit of any employee of the City which shows service in conformity with this Section. Building and Fire Life Safety Commission action, Nuisance Abatement Board action, Building Officer administrative action, other correspondence between the City and the building owner or building owner’s representative, or other evidence of knowledge of notification shall also be deemed as proof of giving notice. (d) Recordation. At the time that the Building Officer serves the aforementioned order, the Building Officer shall file with the Office of the County Recorder a certificate stating that the subject building is within the scope o f this Chapter. The certificate shall also state that the building owner has been ordered to structurally analyze the building and to structurally alter it when the Building Officer determines the building is not in compliance with this Chapter. If the building is demolished, found not to be within the scope of this Chapter, or is structurally capable of resisting minimum seismic forces required by this Chapter as a result of structural alterations or an analysis, the Building Officer shall file w ith the Office 88 of the County Recorder a certificate terminating the status of the subject building as being classified within the scope of this Chapter. 8.76.080 Time limits for compliance. The owner of any building covered by this Chapter shall comply wi th the following time limits. Action by Building Owner Time Limits from Date of Service of Order Structural Evaluation Report 3 Years or 36 Months Application for Building Permit and Submission of Plans 12 Years or 144 Months Final Approval 20 ears or 240 Months SECTION 7. Chapter 8.80 of the Santa Monica Municipal Code is hereby amended to read as follows: Chapter 8.80 Mandatory Seismic Retrofit Requirements for Existing Non - Ductile Concrete Buildings SEISMIC STRENGTHENING PROVISIONS FOR EXISTING NON -DUCTILE CONCRETE BUILDINGS 8.80.010 Purpose. The purpose of this Chapter is to promote the public welfare and safety by reducing the risk of death or injury that may result from the effects of earthquakes on existing concrete buildings. Older concrete buildings are typically vulnerable in seismic events due to deficiencies in the lateral force resisting system (b eams, columns and joints) that render the building incapable of sustaining gravity loads when the building is subjected to 89 earthquake -induced lateral displacements. This Chapter creates minimum standards to mitigate hazards from these structural deficienc ies. Adherence to these minimum standards will improve the performance of these buildings during earthquakes and reduce, but not necessarily prevent , the loss of life, injury or earthquake -related damage. The purpose of this Chapter is to promote public safety and welfare by reducing the risk of death or injury that may result from the effects of earthquakes on concrete buildings and concrete frame buildings with masonry infills. 8.80.020 Scope and Applicability . (a) The provisions of this Chapter shall apply to any concrete building built under building code standards enacted before January 1 1 , 1977. (b) Buildings described in subsection (a) above that have compl eted all required seismic retrofit with a lateral load resisting analysis and structural design plans, and obtained valid final approval from the City of Santa Monica prior to the adoption of this Ordinance , are exempt from the requirements this Chapter. (c) An owner of any buildings within the scope of this Chapter shall demonstrate compliance with the mandatory seismic retrofit requirements of this Chapter, as set forth in Section 8.80.050, consistent with the time limits set forth in this Chapter. The provisions of this Chapter shall apply to all buildings that were designed under building codes in effect prior to January 11, 1976, or built with building permits issued prior to January 11, 1978, and said buildings have concrete floors or roofs supported by reinforced concrete walls or concrete frames and columns, or said buildings have concrete frames with masonry infills. 90 Buildings designated as historically or architecturally significant landmarks on national, State or local historical registers shall also comply with the provisions of this Chapter. At the Building Officer’s discretion, modifications to the standards set forth in this Chapter may be permitted when such modifications are consistent with the provisions of the State Historical Building Cod e. Seismic strengthening in place prior to the effective date of the ordinance codified in this Chapter shall be evaluated according to the provisions of this Chapter and modified if deemed necessary by the Building Officer. 8.80.030 Definitions. ASCE 41 -13 (2014 Edition) is a standards publication by the American Society of Civil Engineer entitled “Seismic Evaluation and Retrofit of Existing Buildings” and describes deficiency –based and systematic procedures to evaluate and retrofit existing buildings to withstand the effects of earthquakes. This publication is referenced in Chapter 35 of the California Building Code. Concrete building is a building having concrete f loors and/or roofs, either with or without beams, supported by concrete walls and/or concrete columns, and/or concrete frames with or without masonry infills, or any combination thereof. Masonry infill is the unreinforced or reinforced masonry wall const ruction within a reinforced concrete frame. For purposes of this Chapter, the applicable definitions in the Building Code and the following shall apply: Building Code is the Building Code of the City of Santa Monica. 91 Commenced construction is construction pursuant to a valid building permit which has progressed to the point that one of the called inspections as required by the Building Officer has been made and the work for which the inspection has been called has been judged by the Buildin g Officer to be substantial and has been approved by the Building Officer. Date of engineering report submittal is either that date upon which the report was due to be submitted to the City, or the date of actual submittal to the City, whichever is earlier . Masonry infill is masonry, both unreinforced and reinforced, constructed within reinforced concrete frame members. Type I building is any non -ductile concrete building that must be usable in the event of an emergency, and shall include hospitals, police and fire stations and disaster recovery centers. Type II building is any non -ductile concrete building with one hundred or more occupants. Type Ill building is any non -ductile concrete building with at least twenty but fewer than one hundred occupants. Typ e IV building is any non -ductile concrete building with fewer than twenty occupants. 8.80.040 Compliance requirements General requirements . The structural evaluation, structural analysis report, and structural design plans for the seismic strengthening and retrofit for Non -Ductile Concrete buildings shall be 92 conducted by a State of California licensed civil or structural engineer, or a State o f California registered architect. For Non -Ductile Concrete buildings over 55 feet in height as described by Section 8.44.090 of the Santa Monica Municipal Code, the structural evaluation, structural analysis report, and structural design plans shall be conducted by a State of California licensed structural engineer. Plans and associated documents shall bear the seal and signature of the design professional. (a) The owner of each building within the scope of this Chapter shall cause an investigation of th e existing construction and a structural analysis to be made of the building by a civil or structural engineer or architect licensed by the State of California. If the building does not meet the minimum standards specified in this Chapter, the owner shall cause it to be structurally altered to conform to such standards. (b) The owner of each building within the scope of this Chapter, which has been analyzed to demonstrate compliance or structurally altered to comply with the minimum earthquake standards in this Chapter, shall maintain such building in conformity with the requirements of this Chapter in effect at the time of such analysis or structural alteration. (c) Buildings within the scope of this Chapter may not be added to or structurally altered or ot herwise remodeled without first complying with the provisions of this Chapter unless the Building Officer determines that the alterations are minor in nature. (d) Notwithstanding any other provisions of this Code to the contrary, it is unlawful for any person, firm or corporation to maintain, use or occupy any building within the 93 scope of this Chapter which does not meet the minimum earthquake standards specified in this Chapter within any of the time periods established. This provision shall not apply i f alteration or repair work has commenced to bring the building into compliance with requirements of this Chapter, and such work is proceeding in accordance with the time limits set forth in any order of the Building Officer or determination of the Nuisanc e Abatement Board. 8.80.050 Engineering analysis and design Demolition . (a) Scope of analysis. This Chapter requires the alteration, repair, retrofit, replacement or addition of structural elements and their connections to meet the following requirements in this section. (b) Building structural analysis, design and evaluation. The building shall m eet one of the following criteria: 1. Strength of the lateral -force resisting system shall meet or exceed seventy -five percent (75%) of the base shear specified in the California Building Code seismic provisions. Elements not designated to be part of the lateral -force resisting system shall be adequate for gravity load effects and seismic displacement due to the full (100%) of the design story drift specified in the California Building Code seismic provisions. 2. Meet or exceed the requirements specified for “Basic Safety Objectives” from ASCE 41 -13 using ground motions and procedures established by the City based on ASCE 41 -13 . An owner desiring to demolish a building must nevertheless comply with the strengthening provisions of this Code within the time allowed unless the owner receives 94 permission to demolish the building prior to the time limits set forth in Section 8.80.060 for the filing of a permit and the submitting of plans to the Building Officer. The owner shall submit a demolition permit application to the Building Officer and shall meet all of the requirements for demolition imposed by this Code, including but not limited to, those requirements set forth in Section 9.04.10.16.010 of this Code, be fore a demolition shall be permitted. Nothing in this Chapter shall be deemed to relieve a building owner of meeting the requirements for demolition of a building imposed by any other applicable law or regulation. 8.80.060 Time limits for compliance Time period for compliance . The owner of any building covered by this Chapter shall comply with the following time limits. Action by Building Owner Time Limits from Date of Service of Order Structural Evaluation Report 3 Years or 36 Months Application for Building Permit and Submission of Plans 4 Years, 6 Months or 54 Months Final Approval 10 Years or 120 Months (a) Engineering Report. Within two hundred seventy -five days of the date of notice to the owner by the City, the owner of any building subject to the provisions of this Chapter shall submit an engineering report to the Building and Safety Division. For structures over three stor ies in height, the report shell be based upon a dynamic lateral - force analysis except for structures where resistance to all lateral loads is provided only by either new or existing shear walls that will be upgraded to the current Code, in which 95 case the r eport may be based upon a static lateral force analysis. For structures three stories or less, the report shall be based upon a static lateral load analysis. (b) The report shall demonstrate whether the structure conforms to the earthquake design provision s contained in Appendix 8 of the Uniform Code for Building Conservation, 2000 Edition or the Building Code in effect at the time the report is submitted to the City. If the report concludes the structure does not comply with either of these standards, the structure shall be strengthened to comply with the standards within the time periods shown in Table 8.80 -A below. Table 8.80 -A Time Limits for Owner Building Type File for Permit/Submit Plans Commence Construction Complete Construction I 60 days from date of engineering report submittal 150 days from date of engineering report submittal 1 year from date of engineering report submittal II 180 days from date of engineering report submittal 270 days from date of engineering report submittal 3 years from date of engineering report submittal III 1 1/2 years from date of engineering report submittal 1 year 8 months from date of engineering report submittal 3 years from date of engineering report submittal IV 2 years 5 months from date of engineering report sub mittal 2 years 8 months from date of engineering report submittal 4 years from date of engineering report submittal 96 8.80.070 Administration. (a) Building Classification. The Building Officer shall determine the occupant load and classification of building type. The occupant load shall be determined in accordance with the Building Code and shall include the entire building plus the occupant load of any adjac ent building that interconnects with the subject building or uses the subject building for exiting purposes. (b) Contents of Order. When the Building Officer determines that a building is within the scope of this Chapter, the Building Officer shall issue a n order as provided herein. The order shall specify that the building has been determined by the Building Officer to be within the scope of this Chapter and, therefore, is required to meet the seismic strengthening provisions of this Chapter. The order sha ll specify the building type classification and shall set forth the owner’s alternatives and time limits for compliance. (c) Service of Order. The order shall be in writing and may be given either by personal delivery thereof to the owner or by deposit in the United States mail in a sealed envelope, postage prepaid, addressed to the owner as shown on the last equalized assessment roll. Service by mail shall be deemed to have been completed at the time of deposit in the U.S. mail. The failure of any owner to receive such notice shall not affect in any manner the validity of any of the proceedings taken thereunder. Proof of giving notice may be made by an affidavit of any employee of the City which shows service in conformity with this Section. Building and Fi re Life Safety Commission action, Nuisance Abatement Board action, Building Officer administrative action, other correspondence 97 between the City and the building owner or building owner’s representative, or other evidence of knowledge of notification shall also be deemed as proof of giving notice. (d) Recordation. At the time that the Building Officer serves the aforementioned order, the Building Officer shall file with the Office of the County Recorder a certificate stating that the subject building is wit hin the scope of this Chapter. The certificate shall also state that the building owner has been ordered to structurally analyze the building and to structurally alter it when the Building Officer determines the building is not in compliance with this Chap ter. If the building is either demolished, found not to be within the scope of this Chapter, or is structurally capable of resisting minimum seismic forces required by this Chapter as a result of structural alterations or an analysis, the Building Officer shall file with the Office of the County Recorder a certificate terminating the status of the subject building as being classified within the scope of this Chapter. 8.8 0.080 Strengthening provisions. (a) Essential and Hazardous Facilities. Essential and hazardous facilities, shall be strengthened to meet the requirements of the Building Code of the City of Santa Monica for new buildings of the same occupancy category. (b) All Other Buildings. All buildings, other than essential or hazardous facilities, shall be strengthened to meet the requirements of Appendix Chapter 8 of the Uniform Code of Building Conservation, 2000 Edition published by the International Conference of Building Officers, adopted herein by reference, or the Building Code. The earthquake loading used for determination of demand on elements and the structure, shall correspond to that required by the Building Code for new buildings. 98 SECTION 8. Chapter 4 .36 of the Santa Monica Municipal Code is hereby amended to read as follows: Chapter 4.36 TENANT RELOCATION ASSISTANCE 4.36.010 Definitions. For purposes of this Ch apter, the following words and phrases shall have the following meaning: (a) Comparable Housing . A replacement unit shall be comparable to the existing unit if both units are reasonably comparable in size, number of bedrooms and bathrooms, accessibility, price, location (which may be in either Santa Monica or Los Angeles), proximity to services and institutions upon which the displaced tenant depends, and amenities, including the allowance for pets should the tenant have pets. (b) Person with Disabilities D isabled Person . Any person who is receiving benefits from a Federal, State, or local government, or from a private entity on account of a permanent disability that prevents the person from engaging in regular, full -time employment. (c) Displaced Tenant . An y tenant who vacates a rental housing unit in the City for any of the reasons set forth in Section 4.36.020 or 4.36.100 (a). (d) Landlord . Any owner, lessor, sublessor, or any other person entitled to receive rent for the use and occupancy of a rental housi ng unit, or any agent, representative or successor of any of the foregoing. (e) Minor Child . Any person younger than eighteen years of age. (f) Permanent Relocation . The relocation of a tenant due to permanent termination of tenancy, in which case the tenant will not reoccupy the unit. 99 (g) Rental Housing Unit . A housing unit in the City of Santa Monica including a room in a single -family home, hotel or motel, rooming house or apartment, single -family home, mobile home or mobile home space, trailer or tr ailer space, offered for rent. A dwelling unit lawfully registered with the City’s Rent Control Board also constitutes a “Rental Housing Unit.” “Rental housing unit” does not include any unit occupied pursuant to an innkeeper -guest relationship. (h) Senior Citizen . Any person sixty -two years of age or older. (i) Temporary Relocation . The relocation of a tenant temporarily and where tenancy has not been terminated. (j) Tenant . Any tenant, subtenant, lessee, sublessee, or any other person occupying a rental h ousing unit pursuant to a written or oral rental housing agreement. 4.36.020 When permanent relocation fee required. (a) A relocation fee shall be paid in accordanc e with the provisions of this Chapter by any landlord who terminates or causes the termination of a tenancy for any of the following reasons: (1) The landlord seeks to withdraw all rental housing units from the rental housing market as provided in Governme nt Code Sections 7060 et seq. (2) The landlord seeks to recover possession of a rental housing unit pursuant to Section 1806(a)(8), 1806(a)(9), 2304(a)(8), or 2304(a)(9) of the City Charter. (3) The landlord seeks to recover possession to demolish or other wise withdraw a rental housing unit from residential rental housing use, including units that were illegally converted to residential use, after having obtained all proper permits from the City, if any such permits are required. 100 (b) A relocation fee shall be paid in accordance with the provisions of this Chapter to a displaced tenant who serves a landlord with a notice to terminate tenancy after having received written notice from either the landlord or the Santa Monica Rent Control Board that the landlord has filed a notice of intent to withdraw residential rental units pursuant to Government Code Section 7060.4 and Santa Monica Rent Control Board Regulation 16002(a) or an application for removal permit pursuant to Santa Monica Charter Section 1803(t). (c) The fee required by this Chapter shall be due and payable to a displaced tenant whether or not the landlord actually utilizes the rental housing unit for the purposes stated in the notice of eviction. 4.36.030 Notice to tenants being displaced. (a) Any notice to terminate a tenancy which is served upon tenants for any of the reasons set forth in Section 4.36.020 shall be accompanied by the following on the form provided by the City: (1) A written statement of the rights and obligations of tenants and landlords under this Chapter; (2) A written statement informing the tenants that the required relocation fee has b een placed in an escrow account or other account approved by the City; (3) A written statement that the landlord has complied with Section 4.36.050 . If the landlord has complied with Section 4.36.050 by obtaining City approval of a Displacement Plan, a cop y of the Displacement Plan shall accompany the written statement. 101 (b) A landlord shall comply with the provisions of this Section within two working days after receiving a tenant’s notice to terminate tenancy as set forth in Section 4.36.020 (b). 4.36.040 Amount of relocation fee —Permanent relocation. The amount of the permanent relocation fee payable pursuant to the provisions of this Chapter shall be established in accordance with the following formula: 2011 relocation fee adjusted for inflation by the percentage change in the rent of primary residence component of the CPI -W Index for the Los Angeles/Riverside/Orange County area, as published by the United States Dep artment of Labor, Bureau of Labor Statistics, between November 2011 and the July 1st preceding the date of vacancy rounded to the nearest fifty dollars. This amount shall be updated annually commencing on July 1, 2012 and on July 1st of each year thereafte r. (a) The 2011 permanent relocation fee established pursuant to Ordinance 2383CCS and determined according to the size of the retail housing unit, was as follows: Apartment Size 2011 Relocation Amount 2011 Augmented Amount Single or studio $ 7,800 $ 8,900 One bedroom 12,050 13,850 Two or more bedrooms 16,300 18,750 (b) If a tenant is evicted from more than one rental housing unit on a property, the tenant shall not be entitled to receive separate permanent relocation fees for each rental housing unit. The tenant shall receive a single relocation fee based on the combined total number of bedrooms in the rental housing units from which the tenant is 102 being evicted. If one of the rental housing units is a bachelor or single unit, it shall be counted a s a one bedroom unit for purposes of determining the amount of the relocation fee (e.g., a tenant who is evicted from a bachelor rental housing unit and a one bedroom rental housing unit would receive relocation benefits for a two bedroom unit). (c) If the rental housing unit from which the tenant is being evicted is furnished, two hundred fifty dollars shall be deducted from the amount set forth in subsection (a) of this Section. For purposes of this subsection, a rental housing unit shall be considered to be furnished if the landlord has provided substantial furnishings in each occupied room of the rental housing unit. (d) If one or more of the displaced tenants is a senior citizen or disabled person, or is a tenant with whom a minor child resides, an augm ented amount shall be paid as set forth in subsection (a) of this Section. The amount added pursuant to this subsection shall be adjusted annually pursuant to the formula specified above commencing on July 1, 2012, and each July 1st thereafter. (e) Any ten ant still in possession of a rental unit after the permanent relocation amounts have been updated pursuant to this Section, shall be entitled to the updated relocation amounts even if the landlord commenced the termination of the tenancy prior to the updat e. In the event that a landlord has already complied with the provisions of Section 4.36.060 based on the relocation amounts previously in effect, but has not yet received a written request from a tenant for distribution of the fee pursuant to Section 4.36 .070 , the landlord shall place in escrow the additional amount of relocation fee required by this Section within five working days of the effective date of the updated amount. 103 4.36.050 Additional fee for required counseling. (a) For each rental housing unit from which tenants are displaced for any of the reasons set forth in Section 4.36.020 (a), prior to service of a notice to terminate tenancy, the landlord shall pay a fee to the City in the amount of two hundred fifty dollars to be used by the City to pay for counseling or other assistance required by displaced tenants as a result of displacement. (b) In lieu of the fee required by subsection (a) of this Section, a l andlord may prepare a Displacement Plan which must be approved by the Housing and Economic Development Department prior to service of a notice to terminate tenancy. The Displacement Plan shall identify the special needs of the displaced tenants, identify t he types of assistance that will be provided and include a commitment to pay for any such assistance. At the time of submitting the Displacement Plan to the City for review and approval, the landlord shall pay a fee to the City for such review and approval in the amount of one hundred dollars for each rental housing unit. 4.36.060 Deposit of relocation fee into escrow for permanent relocation. (a) The permanent reloca tion fee required by this Chapter shall be placed in an escrow account prior to service by a landlord upon any tenant of a notice to terminate tenancy for one of the reasons set forth in Section 4.36.020 (a) or within two working days of service by a tenant upon a landlord of notice to terminate tenancy as set forth in Section 4.36.020 (b). All costs of an escrow opened pursuant to the provisions of this Section shall be borne by the landlord. Escrow instructions shall be approved by the City. (b) The escrow instructions shall provide that monies deposited in the escrow account shall only be distributed to displaced tenant in accordance with the instructions 104 of the landlord and that no monies deposited in escrow may be returned to the landlord without the writ ten approval of the City. (c) In lieu of deposit of the permanent relocation fee in an escrow account, a landlord may deposit the fee in another account approved by the City. 4.36.070 Payment to displaced tenants of permanent relocation fee. (a) Within two working days of the written request by the tenant, the landlord shall deliver written instructions to the escrow holder to distribute all or a portion of the perman ent relocation fee to a third party providing moving or replacement housing to the tenant. The instructions shall direct the escrow holder to make the distribution within three working days of delivery of the instructions. (b) Within two working days of th e vacation of the rental housing unit, the landlord shall deliver written instruction to the escrow holder to distribute the amount of the remaining relocation fee to the displaced tenant or displaced tenants of such rental housing unit. The instruction sh all direct the escrow holder to make the distribution within three working days of delivery of the instructions. (c) The entire fee shall be paid to a tenant who is the only displaced tenant in a rental housing unit. If a rental housing unit is occupied by two or more displaced tenants, the permanent relocation fee shall be paid to all displaced tenants jointly. In no event shall a landlord be liable to pay a total amount more than the fee required by Section 4.36.040 of this Chapter for one rental housing unit, and the landlord shall have no responsibility or liability for disputes between displaced tenants over allocation of the relocation fee between such displaced tenants. 105 (d) In the event the landlord has been required to commence a legal action to reco ver possession of the rental housing unit and a decision is rendered or a judgment has been entered in favor of the landlord prior to the tenant’s vacation of the unit, the landlord may instruct the escrow holder to withhold from distribution to the displa ced tenant or displaced tenants of such rental housing units any unsatisfied monetary award provided in such decision or judgment in favor of the landlord. Upon the judgment becoming final, the City shall authorize the escrow holder to return to the landlo rd the amount withheld. If no decision has been rendered or no judgment has been entered for a monetary award in favor of the landlord prior to the tenant’s vacation of the unit, the landlord must authorize the distribution of the entire relocation fee in accordance with Section 4.36.070 . 4.36.080 Physical relocation in lieu of fee. (a) In lieu of the permanent relocation fee required by Sections 4.36.040 and 4.36.050 , the landlord may, at the landlord’s option, relocate the displaced tenant into a comparable replacement housing unit satisfactory to the tenant, in which event the landlord shall be liable only for the actual costs of relocating the tenant, except that t his Section shall not abrogate any rights already created by Section 1806(a)(8)(ii) of the City Charter. A tenant shall not unreasonably withhold approval of a comparable replacement rental housing unit offered by the landlord. (b) If a tenant displaced fo r the reason set forth in Section 4.36.020 (a)(2) elects to occupy a noncomparable vacant unit on the same property from which that tenant is being displaced, pursuant to the terms set forth in Section 1806(a)(8) of the City Charter, 106 in lieu of the permanen t relocation fee required by Sections 4.36.040 and 4.36.050 , the landlord shall only be liable for the actual costs of relocating the tenant. 4.36.085 Prohibition ag ainst agreements limiting public participation. No landlord shall, with respect to property used as rental housing, any rental housing agreement or other tenancy or estate at will, however created, do any of the following: (a) Enter into an agreement with a tenant which prohibits or limits the tenant from participating in the City’s public process, including speaking at a meeting of the City Council or any City Commission, submitting written comments to the City, or otherwise communicating with City elected officials, appointed officials, and employees on any subject. (b) Attempt to enforce an agreement such as described in subsection (a). (c) Withhold deposit of relocation fees into escrow or withhold payment of such fees or other payments otherwise owed to the tenant in an attempt to induce a tenant to enter into an agreement such as described in subsection (a). 4.36.090 Remedies. (a) In any action by a landlord to recover possession of a rental housing unit for one of the reasons set forth in Section 4.36.020 , the landlord shall allege and prove compliance with this Chapter. (b) Any landlord who fails to provide relocation assistance a s required by Sections 4.36.040 , 4.36.050 , 4.36.070 and 4.36.100 or who violates Section 4.36.085 of this Chapter shall be subject to injunctive relief and be liable in a civil action to the tenant to whom such assistance is due for damages in the amount o f the relocation fee the landlord 107 has failed to pay, a civil penalty in the amount of five hundred dollars and reasonable attorneys’ fees and costs as determined by the court. The court may also award punitive damages in a proper case as defined by Civil C ode Section 3294. Any person, including the City, may enforce the provisions of this Chapter by means of a civil action. (c) Any person violating any of the provisions of or failing to comply with the requirements of this Chapter, including failure to comp ly with a relocation order issued by the Building Officer pursuant to Section 4.36.100 , shall be guilty of an infraction which shall be punishable by a fine not exceeding $250.00, or a misdemeanor and upon conviction shall be punished by a fine of not grea ter than $500.00 or by imprisonment in the County Jail for not more than six months, or by both such fine and imprisonment. (d) Failure to comply with a relocation order shall be considered a strict liability offense; accordingly, the prosecution shall not be required to prove criminal intent or that the violator meant to violate any provision of this Chapter. (e) Any person convicted of violating any provision of this Chapter shall be required to reimburse the City its full investigative costs. (f) If a la ndlord fails or refuses to provide relocation benefits required by this Chapter, and the City chooses to pay such benefits to tenants in the landlord’s place, the City shall have the right to recover such monetary outlays, plus any administrative fees incu rred by the City, from the landlord as restitution in any criminal case filed pursuant to this Chapter or in any appropriate civil or administrative proceeding. (g) Unless otherwise specifically authorized, no landlord shall attempt to secure from a tenant any waiver of any provision of this Chapter. Any agreement, whether written 108 or oral, whereby any provision of this Chapter is waived, shall be deemed against public policy and shall be void. (h) Any contractual term which violates Section 4.36.085 of this Chapter, whether written or oral, shall be deemed against public policy and shall be void. (i) Nonexclusive Remedies and Penalties. The remedies provided in this Chapter are not exclusive, and nothing in this Chapter shall preclude any person from seeking any other remedies, penalties or procedures provided by law. 4.36.100 Temporary relocation mandated by code compliance or by government order. (a) A landlord is req uired to provide temporary relocation benefits to tenants as required by this Section when: (1) The landlord is required to temporarily recover possession of a rental housing unit in order to comply with housing, health, building, fire or safety laws of th e State of California or the City of Santa Monica, or (2) A rental housing unit has been rendered uninhabitable, necessitating the tenant(s) of the housing unit to no longer dwell within that unit, or (3) A tenant is required to vacate a rental housing uni t upon the order of any government officer or agency. A landlord’s obligations under this subsection shall be self -executing; nonetheless, the Building Officer may issue a relocation order to the landlord to compel performance under this Section. No person shall fail to comply with any such relocation order. (b) These relocation benefits shall include both temporary housing as provided in subsection (c) of this Section and moving costs as provided in subsection (d) of this 109 Section and shall be paid until su ch time temporary relocation benefits are no longer required by law, such as when legal tenancy is terminated or the tenant is returned to his/her dwelling unit which has been made habitable. Provision of temporary relocation benefits does not relieve the Landlord’s obligation to provide permanent relocation benefits as required by this Chapter. (c) The type of temporary housing, required by this Section is dependent on the duration of the tenant’s displacement. When the Building Officer or landlord determi nes the need for a tenant to vacate, he or she shall estimate the projected duration of the vacancy. That estimate will determine whether subsection (c)(1) or (c)(2) of this Section must be followed. If the Building Officer orders relocation, he or she sha ll provide notice to the landlord and all affected tenants of the relocation requirements and responsibilities pursuant to this Section. This notice may include a copy of this Section and the City Council’s resolution regarding per diem rates. The landlord shall facilitate the Building Officer’s provision of tenant notification by providing forwarding contact information for affected tenants if the tenants vacated the premises prior to the Building Officer’s Order. If the landlord determines that the provis ions of this code require a tenant to vacate, the landlord shall provide notice of the estimated relocation period to affected tenants and relocation benefit requirements and responsibilities established by this Section. (1) Relocation Less Than 30 days. I f it is anticipated that a tenant will be displaced for a period less than thirty days, the landlord shall pay the tenant relocation costs in the per diem amounts set by the City Council pursuant to subsection (e). The per diem amount shall be calculated t o include compensation for the following: 110 (A) Temporary relocation to a motel or hotel accommodation which is safe, sanitary, located in Santa Monica and contains standard amenities such as a telephone; (B) Meals, if the temporary accommodation lacks cooki ng facilities; (C) Laundry, if the rental property included laundry facilities; and (D) Accommodations for lawful pets if the temporary accommodation does not accept pets. The landlord shall have the option, in lieu of providing tenant relocation costs in accordance with this subsection, of providing the tenant with comparable housing pursuant to subsection (c)(2) for the period of the displacement or temporary placement in a safe and sanitary hotel/motel if the relocation is estimated to be five (5) days or less. If the relocation extends beyond five (5) days , the tenant shall be entitled to the per diem or comparable housing, unless the tenant explicitly agree s to extend his/her stay in the ho tel/motel . The tenant shall remain responsible to pay to the landlord rent which falls due for the tenant’s existing unit during the period of displacement. (2) Relocation 30 days or Greater. If it is anticipated that the displacement will be for a period of thirty days or greater, the landlord shall provide either temporary rental housing or per diem payments in accordance with Subsection (c)(1) of this Section, prepaid by the landlord in weekly increments. If the landlord elects temporary rental housing, such housing shall be comparable to the tenant’s existing housing, as determined by the Building Officer. However, a landlord’s election of temporary rental housing shall not be revocable by the landlord, once the tenant moves into the temporary housing. I n cases where the landlord elects temporary rental housing, the landlord must provide per diem payments in accordance with Subsection (c)(1) of this Section until such 111 time the displaced tenant is housed in temporary rental housing. The landlord shall pay all costs associated with the temporary housing, including rent, even if the temporary housing is more expensive than the tenant’s existing unit. The tenant shall remain responsible to pay rent to the landlord for the tenant’s existing unit during the peri od of displacement. (3) The relocation benefits required by this Section shall be paid within twenty -four hours of when any condition outlined in Subsection (a) of this Section arises, or at least twenty days prior to the vacation date set forth in any ord er or notice to vacate, whichever is later. (4) If the landlord or the Building Officer determines that the actual relocation period will be longer than a landlord has paid for, or than projected by the landlord or the Building Officer, the landlord must n otify the affected tenant as soon as the determination is made and promptly pay the tenant the amount owed and remain current on such payments. If a tenant’s actual vacancy period is shorter than the period the landlord has paid for, the tenant must repay any overpaid amount to the landlord within thirty days of receiving written notice from the landlord of the overpayment. The landlord must make a good faith effort to monitor the necessity of the tenant’s continued displacement and provide the tenant with advance notice of any changes to the anticipated relocation period. (5) The landlord shall ensure that temporary r elocation of a tenant does not exceed the estimated relocation period as determined by the Building Officer pursuant to this Section . Should a longer period be necessary, the landlord shall request an extension from the Building Officer and demonstrate good cause for such an extension. 112 (5 6 ) The landlord and the tenant may mutually agree upon a housing type or relocation benefit other than what is required by this Section. The landlord may not coerce any tenant into such an agreement. Any such coercion may constitute unlawful tenant harassment, subject to the remedies set forth in Chapter 4.56 of this Code. (d) Moving costs shall consist of all actual reasonable costs of moving, including transportation of personal property, packing and unpacking, insurance of personal property while in transit, compensation for any damage occurring during moving, necessary storage of personal prop erty, disconnection and reconnection of utility services related to the move and any other additional costs attributable to a tenant’s special needs, including needs resulting from disability or age. (e) The City Council shall periodically establish by res olution reasonable per diem rates for the following items of temporary relocation expenses required under this Section. These rates shall be adjusted annually for inflation by the percentage change in the Consumer Price Index (“CPI”) commencing on July 1, 2007 and on July 1st of each year thereafter. (1) Hotel accommodations; (2) Meal allowance; (3) Laundry allowance; (4) Pet accommodations. (f) The displacement and relocation of a tenant pursuant to this Section or Section 8.100.030 shall not terminate the tenancy of the displaced tenant. The displaced tenant shall have the right to reoccupy his or her unit upon the completion of the work necessary for the unit to comply with housing, health, building or safety laws, any governmental 113 order, or the unit is otherwise restored to a habitable condition, the tenant shall retain all rights of tenancy that existed prior to the displacement. (g) Upon receiving a relocation order from the City, t he landlord is required to promptly obtain any required permits and/or approvals from the City and/or other regulatory agency who has jurisdiction over the required work, promptly commence the necessary work to restore the affected unit(s) to a habitable condition , diligently work towards completion of the work and return all affected tenants to th eir units . (g h ) If a displaced tenant’s behavior causes the tenant to be removed or evicted, for cause, from his/her temporary housing accommodations, the landlord may request and the Building Officer may grant early termination of temporary relocation obligations with respect to that tenant. The Building Officer may develop criteria that would aid in reviewing such requests. (h i ) A landlord or tenant who disputes a notice or order rega rding temporary relocation benefits may request a hearing pursuant to the procedures set forth in Chapter 6.16 . Any such hearing request shall be filed with the Building Officer within two business days of the notice or order on a form provided by the Buil ding Officer. (i j ) An appeal shall not automatically stay the underlying relocation order. However, the Building Officer or the Hearing Examiner on appeal may grant a written request to stay the relocation order. Any such request to stay the relocation order shall be conside red as soon as practicable. The Hearing Examiner may choose to make any preliminary inquiries necessary, including holding a preliminary in -person or telephonic hearing, to receive preliminary facts. However, if the Building Officer rejects a landlord’s wr itten request to stay a relocation order pending an appeal and the landlord ultimately 114 prevails in overturning the Building Officer’s relocation order, the City shall reimburse the landlord any actual reasonable housing, moving and storage costs incurred b y the landlord as required by Section 4.36.100 , which shall begin to accrue on the first business day after the date the City receives a written stay request. The landlord may not recover other costs, such as attorney’s fees or court costs, from the City. 4.36.110 Applicability of relocation assistance requirements as provided in this Chapter. (a) A tenant shall be entitled to the relocation benefits established by th is Chapter pursuant to Section 4.36.100 . (b) The landlord shall comply with the requirements contained in Sections 4.36.030 , 4.36.040 , 4.36.050 and 4.36.060 within five days of the effective date of any ordinance codified in this Chapter or any update of t he fee amount pursuant to Section 4.36.040 in the event that a notice to terminate tenancy for one of the reasons set forth in Section 4.36.020 (a) has already been served on a tenant or a notice to terminate tenancy pursuant to Section 4.36.020 (b) has alre ady been served on a landlord. In the event that on the effective date of any such amendment or update, a landlord has complied with the provisions of Section 4.36.060 previously in effect, but has not yet received a written request from a tenant for distr ibution of the fee pursuant to Section 4.36.070 , the landlord shall place in escrow the additional amount of relocation fee required by Section 4.36.040 within five working days of the effective date of the amendment or update. (c) Nothing in this Chapter shall limit the amount of the relocation fee that the City Council may require under Government Code Section 65863.7. 115 (d) An administrative citation’s fine amount shall be doubled, when the citation is issued in connection with a landlord’s commencement of construction work without first obtaining all necessary governmental permits and that the work necessitated the relocation of a tenant. 4.36.120 Applicability of Ch apter to certain situations. (a) Notwithstanding Section 4.36.110 and 4.36.100 (c), the requirements set forth in this Chapter shall not apply to any tenant whose tenancy is terminated pursuant to a lawful notice to terminate tenancy pursuant to Section 18 06(a) of the City Charter served on or before June 10, 1986. (b) No landlord shall be required to pay temporary relocation benefits pursuant to Section 4.36.100 if the displacement and relocation of the tenant is the result of an earthquake or other natura l disaster, terrorist attack, or other incident occurring or substantially initiated off of the property from which relocation is required, but not caused by the landlord, as determined by the Fire Marshal or Building Officer (such as vehicle accident, cri minal activity, public utility failure or adjacent building failure). However, to the extent that any person, other than the landlord, causes tenant relocation pursuant to Section 4.36.100 , such person shall be responsible for the provision of temporary re location benefits, as required by Section 4.36.100 . (e c ) The displacement and relocation of a tenant for repair and retrofitting pursuant to Municipal Code Chapters 8.60 , 8.64 , 8.68, 8.72 , 8.76 , and 8.80 shall not terminate the tenancy of the displaced tenant. The displaced tenant shall have the right to reoccupy the unit upon the completion of the repairs and retrofitting and shall retain all rights of tenancy that existed before the displacement. 116 (c) Se ction 4.36.100 shall not be applicable if the displacement and relocation of the tenant is necessary to comply with the repair and retrofitting requirements of Municipal Code Chapters 8.60 , 8.64 , 8.72 , 8.76 , and 8.80 . However, in the event of such displacement, a landlord shall be responsible to pay the displaced tenant the difference between reasonable rent actually paid for comparable temporary accommodations, and the rent which would have been payable to the landlord had the displacement not occu rred, for any period of displacement which exceeds the following limits: (1) For buildings less than five stories in height, one hundred eighty days, or if asbestos removal is required, two hundred seventy days. (2) For buildings five stories or more in he ight, two hundred seventy days, or if asbestos removal is required, three hundred sixty days. (d) The Building Officer and Director of Planning and Community Development may jointly authorize a longer time period to complete repair and retrofitting if, pri or to displacement, they find that due to circumstances unique to the building, the repair and retrofitting will take longer than the preceding time limits. Additionally, after tenant displacement, the Building Officer and Director of Planning and Communit y Development may jointly grant a reasonable extension of the time limit if they find that the landlord is proceeding diligently and expeditiously with repair and retrofitting, and that the inability to complete the project within the established time limi t is due to the occurrence of events that were reasonably unforeseeable by and beyond the control of the landlord; provided, however, that the landlord’s inability to finance such repair and retrofitting shall not be grounds for such an extension. 117 (f d ) No landlord shall be required to provide temporary relocation benefits pursuant to Section 4.36.100 to a tenant if that tenant or his or her guest or invitee was entirely or primarily responsible for causing the condition that necessitated the temporary reloc ation. In such cases, the landlord’s responsibility to provide temporary relocation benefits to other non -responsible tenants remains. (g e ) If a tenant elects to remain in his/her unit (including day, evening, and/or night time hours) following an order directing temporary relocation, said tenant shall not receive relocation benefits. However, the tenant’s right to relocation benefits shall not be affected by the tenant’s limited access to the unit to retrieve personal belongings. (f) If a tenant interferes, obstructs or delays an owner’s ability to conduct necessary repairs to restore a unit to habitable status , the owner’s obligation to provide relocation benefits to th at tenant may be lifted by order of the Building Officer. 4.36.130 Coordination with other relocation requirements. In the event that a landlord is required by any other governmental body to provide relocation benefits to a t enant who receives a notice to terminate tenancy for one of the reasons set forth in Section 4.36.020 , such benefits shall be off -set against the amount of relocation benefits required by Section 4.36.040 . This Chapter shall not apply to any relocation pla n approved by agreement by the Rent Control Board on or before June 24, 1986. 4.36.140 Security deposit for temporary relocation. The Building Officer may require th e landlord to furnish security to the City sufficient to ensure the timely and faithful performance of all work included within the scope of a permit and the payment of all relocation assistance necessitated by the 118 temporary displacement of the tenants, if any, based on an analysis of the following factors: size of project, duration of project, potential for impact on tenant safety, and invasiveness of project. If required, any of the following or similar instruments are acceptable forms of security: (a) A deposit, either with the City or a responsible escrow agent or trust company, at the option of the City, of money or negotiable bonds of the kind approved for securing deposits of public monies; (b) An instrument of credit from one or more financial instit ution subject to regulation by the State or Federal government or a letter of credit issued by such a financial institution; (c) Bond or bonds by one or more duly authorized corporate sureties; (d) A restricted bank account. SECTION 9. Chapter 8.10 0 of the Santa Monica Municipal Code is hereby amended to read as follows: Chapter 8.100 TENANT PROTECTION DURING CONSTRUCTION 8.100.010 Construction means and me thod plan required. (a) When applying for a permit to alter, repair, or rehabilitate any structure that contains one or more dwelling units or mobilehome park, the applicant shall indicate on a form furnished by the Building Officer whether the property is occupied by tenants. (b) If the property is tenant -occupied and, as determined by the Building Officer, the construction work could impact the habitability of any unit on the property, prior to obtaining a permit, the applicant shall submit a construction means and method plan to the Building Officer which contains the information required by Section 8.100.020 . The 119 Building Officer may consult all relevant sources of authority, including Health and Safety Code Section 17920.3 or its successor legislation, to guide his/her determination of habitability. (c) No permit shall be issued until a satisfactory means and method plan is approved by the Building Officer, if required. (d) If the unit or building was not tenant occupied at the time a permit application was submitted, the applicant shall submit a construction means and method plan prior to any unit in the building being tenant occupied. If the Building Officer determines that the work could impact the habitability of any unit on the property given the man ner in which the construction is being undertaken, the requirements of Sections 8.100.020 , 8.100.030 , 8.100.040 , 8.100.050 , and 8.100.060 below shall also apply. (e) The Building Officer may stop construction until all applicable requirements of this Chapt er have been met. 8.100.020 Contents of construction means and method plan. The construction means and method plan required by subsection (b) of Section 8.100.010 shall provide the following information: (a) A detailed description of the construction process, organized sequentially; (b) An explanation of the impact that this construction will have on the occupancy of the units by tenants; (c) The owner’s plan to ad dress the habitability impacts on the tenants created by the proposed construction project; (d) An assessment of whether any or all of the tenants will need to be temporarily relocated during any phase of the work, including relocation intermittently durin g the project . 120 A tenant will need to be temporarily relocated if the conditions of the property or the repair or rehabilitation thereof will render the premises unsafe for continued occupancy ; (e) A description of the construction mitigation measures that the owner will implement to minimize the impacts of noise, dust, vibrations, utility shut -offs, and other construction impacts on tenants ;. (f) A description of all related construction projects at the property that would commence concurrent with or immedi ately after the proposed project is scheduled to end. 8.100.030 Relocation plan. (a) If the construction means and method plan demonstrates, as determined by the Building Officer, that the work being performed on the property may require that tenants be temporarily relocated, the applicant shall also prepare and submit a relocation plan on a form provided by the Building Officer for City approval prior to issuance of a permit which shall contain: (1) The fair and reasonable relocation benefits that will be provided to all displaced tenants as required by Municipal Code Section 4.36.100 ; (2) The timing of the displacement will be provided to all tenants who will be d isplaced; (3) A copy of the notice required by Section 8.100.040 (a) with all information required by Section 8.100.040 (b). (4) Based upon a recent survey and analysis of both the housing needs of persons who will be displaced and the supply of available temporary housing, and considering the competing needs for that housing, verification that sufficient temporary housing of the ty pe required by Section 4.36.100 will be provided; 121 (5) Verification that the owner has adequate resources to provide the required relocation benefits and adequate provisions have been made for the orderly, timely, and efficient relocation of displaced tenan ts to comparable replacement housing. (b) If the Building Officer determined, at the time of permit approval, that temporary relocation was not required and if new construction conditions could potentially impact habitability of any tenant unit, the applic ant must submit an amended means and method plan and obtain all required City approvals prior to commencing any work beyond the scope of work originally approved. If the Building Officer determines that the work could impact the habitability of any unit on the property given the manner in which the change in construction is being undertaken, the requirements of this Section and Sections 8.100.040 , 8.100.050 , and 8.100.060 below shall also apply. 8.100.040 Tenant noticing requirements. (a) Contemporaneous with the submission of a construction means and method plan to the City, the applicant must certify that all affected tenants of the property have received the prop osed means and method plan, the proposed relocation plan if required, and information explaining how to contact responsible City officials regarding the processing of such plans. Provision of the above information to the tenants shall be by hand -delivery, with a proof of service, to each affected tenant of the property or sent by certified mail or otherwise delivered in a form of electronic means acceptable to the Building Officer. (b) Before a permit can be issued for the alteration/repair/rehabilitation o f a building or mobilehome park which required an applicant to prepare a construction means and method plan pursuant to Section 8.100.010 of this Chapter, the applicant must certify 122 that all affected tenants of the property will receive the information req uired by subsection (b) of this Section, in a form approved by the City within five days following the issuance of the permit and that no work shall commence under the permit until five days after the date all affected tenants were notified. This notice sh all be hand -delivered, with a proof of service, to each affected tenant of the property or sent by certified mail or otherwise delivered in a form of electronic means acceptable to the Building Officer. (c) The notice required by subsection (b) of this Sec tion shall contain the following information: (1) A detailed description of the nature and type of construction activity that will be undertaken; (2) Information regarding the scheduling of construction and the periods in which services such as laundry, pa rking, elevators, water and power, will be unavailable; (3) A statement that the construction being undertaken at the property will not terminate the tenant’s tenancy; (4) A statement informing the tenants of their right to seek mitigation from the property owner for nuisance conditions at the property, including, but not limited to, noise, dust, vibrations, utility shut -offs and other construction impacts. Mitigation measures may include, but are not limited to, temporary rent reductions, quiet offi ce space for tenants working at home and temporary accommodations; (5) A statement informing tenants of their right to review and receive free copies of the owner’s approved construction means and method plan and how to obtain; (6) A statement informing te nants of their right to review and receive free copies of the owner’s approved relocation plan, if such plan was required and how to obtain; 123 (7) Information explaining how to contact the project applicant, including the designation of a project manager res ponsible for responding to tenant inquiries, complaints, and requests for mitigation of nuisance conditions; (8) A statement informing tenants that they should immediately contact the City regarding any conditions at the property which they consider to be unsafe, unsanitary, in violation of the City’s technical or safety codes, or in violation of the applicant’s construction means and method plan; (9) For construction projects that exceed thirty days in duration as measured from the date that construction c ommences, the applicant shall also inform the affected tenants that the applicant will provide monthly notices to the affected tenants regarding the progress of construction and will schedule meetings periodically, or at the request by order of the Building Officer, to address the construction progress and obtain tenant input and feedback regarding the construction ;. The Building Officer ’s order to schedule such tenant meeting s is not appealable . (10) Any other information that the Building Officer determines is necessary due to the unique circumstances of the construction work. (d) In addition to the information required by subsection (c) of this Section, the tenant notification shall provide the following information if the project will require the temporary relocation of tenants: A statement that the construction activity may require displacement, but that to the greatest extent practicable, no tenant lawfully occupying the property will be required to move without written notice from the owner in accordance with this Chapter. 124 (e) In addition to the notice required by subsections (a), (b), (c), and (d) of this Section, the landlord shall post the property with a preprinted sign or signs prepared by the City measuring thirty inches by forty inches in size in a conspicuous location visible to tenants that include the information on where to file a complaint with the landlord or landlord’s representative and the City regarding any conditions at the property which any tenant considers to be unsafe, unsan itary, in violation of the City’s technical or safety codes, or in violation of the applicant’s construction means and method plan. 8.100.050 Security. Before rec eiving a permit for a project which requires an applicant to prepare a construction means and method plan pursuant to Section 8.100.010 of this Chapter, the applicant shall furnish security to the City in accordance with Section 4.36.140 of this Chapter. 8.100.060 Compliance with required means and method plan. (a) General . No person shall erect, construct, enlarge, alter, repair, move, improve, remove, sandblast o r convert the use of any building, structure or building service equipment regulated by this Code without complying with all conditions of any required construction means and methods plan. (b) Owner’s Responsibility . The property owner shall remain respons ible for any violation of the construction means and method plan regardless of the responsibility of any other person for the violation or any contract or agreement the owner entered into with a third party concerning the owner’s property or the constructi on that necessitated the preparation of the means and method plan. A licensed contractor serving as the agent 125 of the owner or as the applicant for a permit may be held jointly responsible for violations of the means and methods plan. 8.100.070 Administrative regulations. The Building Officer shall have the authority to promulgate and or adopt administrative regulations to implement the provisions of this Chapter. 8 .100.080 H azardous M aterials (a) A n y owner shall ensure that hazardous material s, such as mold or asbestos, are properly handled and abated during any construction, demolition or modification to a ny building. (b) Whenever handling or abatement of hazardous materials, such as mold or asbestos , is undertaken, the owner shall provide proof , to the satisfaction of the Building Officer , that proper handling and/or abatement procedures, performed by appropriately certified experts, were followed , and that the site is safe for its intended occupancies . (c) T he City may reasonably engage the services of qualified experts, at the owner’s expense, to assist the City in evaluating the owner’s compliance with this section . SECTION 10. Any provision of the Santa Monica Municipal Code or appendices thereto inconsistent with the provisions of this Ordinance, to the extent of such inconsistencies and no further, is hereby repealed or modified to that extent necessary to effect the provisi ons of this Ordinance. SECTION 11. If any section, subsection, sentence, clause, or phrase of this Ordinance is for any reason held to be invalid or unconstitutional by a decision of any court of competent jurisdiction, such decision shall not affect the validity of the remaining portions of this Ordinance. The City Council hereby declares that it would have passed 126 this Ordinance and each and every section, subsection, sentence, clause, or phrase not declared invalid or unconstitutional without regard to whether any portion of the ordinance would be subsequently declared invalid or unconstitutional. SECTION 12. The Mayor shall sign and the City Clerk shall attest to the passage of this Ordinance. The City Clerk shall cause the same to be published once i n the official newspaper withi n 15 days after its adoption. This Ordinance shall become effective 30 days from its adoption. APPROVED AS TO FORM: _________________________ JOSEPH LAWRENCE Interim City Attorney Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C ADDRESS APN BUILDING TYPE # STORIES # UNITS 603 1ST CT (603 OCEAN AVENUE)4293015037-058 Steel Moment Frame 4 22 804 2ND ST (122-128 MONTANA AVE)4292025055-059 Soft Story 3 5 808 2ND ST 4292025002 Soft Story 3 11 834 2ND ST 4292025005 Soft Story 4 15 838 2ND ST 4292025006 Soft Story 2 15 842 2ND ST (842-844 2ND ST)4292025007 Soft Story 2 6 905 2ND ST 4292023019 Non-Ductile Concrete 2 20 918 2ND ST (918-922)4292026003 Soft Story 2 3 927 2ND ST 4292023015 Soft Story 3 15 933 2ND ST 4292023014 Soft Story 3 14 1008 2ND ST 4292027003 Soft Story 4 14 1022 2ND ST 4292027006 Soft Story 3 11 1028 2ND ST 4292027007 Soft Story 3 11 1032 2ND ST 4292027008 Soft Story 4 14 1038 2ND ST 4292027009 Soft Story 2 15 1042 2ND ST (1042-1044 2ND ST)4292027010 Soft Story 2 7 1047 2ND ST 4292022013 Soft Story 2 10 1111 2ND ST 4292021021 Non-Ductile Concrete 17 0 1129 2ND ST 4292021009 Non-Ductile Concrete 8 0 1220 2ND ST 4291001028 Non-Ductile Concrete 2 0 1305 2ND ST 4291013022 Unreinforced Masonry 3 48 1333 2ND ST 4291013024 Steel Moment Frame 6 0 1355 2ND ST 4291013023 Steel Moment Frame 4 0 1410 2ND ST 4291015002 Steel Moment Frame 3 0 1414 2ND ST 4291015003 Unreinforced Masonry 1 0 1418 2ND ST 4291015004 Unreinforced Masonry 2 0 1422 2ND ST 4291015005 Steel Moment Frame 3 0 1520 2ND ST 4291028023 Unreinforced Masonry 2 0 1522 2ND ST (1524)4291028003 Unreinforced Masonry 4 0 2326 2ND ST 4289015026 Soft Story 2 5 2435 2ND ST 4287009017 Soft Story 2 8 2513 2ND ST 4287010039 Soft Story 2 13 2619 2ND ST 4287010035 Soft Story 2 9 2808 2ND ST 4288003015 Soft Story 2 1 2810 2ND ST 4288003016 Soft Story 2 1 2821 2ND ST 4287023028 Soft Story 2 2 2931 2ND ST 4287024023 Soft Story 2 9 3003 2ND ST 4287024065-068 Soft Story 2 4 807 3RD ST 4292017024 Soft Story 2 10 814 3RD ST 4292024003 Soft Story 2 9 827 3RD ST 4292017020 Soft Story 2 10 831 3RD ST 4292017019 Soft Story 3 14 858 3RD ST 4292024010 Soft Story 2 14 860 3RD ST 4292024011 Soft Story 2 14 914 3RD ST 4292023053-062 Soft Story 3 10 918 3RD ST 4292023052 Soft Story 3 9 927 3RD ST 4292018016 Soft Story 2 10 933 3RD ST 4292018015 Soft Story 2 10 937 3RD ST 4292018027 Soft Story 3 30 1001 3RD ST 4292019015 Unreinforced Masonry 3 w/Penthouse 0 1037 3RD ST 4292019012 Soft Story 4 14 1044 3RD ST 4292022007 Soft Story 2 10 1118 3RD ST 4292021024-066 Non-Ductile Concrete 6 43 1202 3RD ST PROMENADE 4291002001 Non-Ductile Concrete 2 0 1242 3RD ST PROMENADE (1244)4291002008 Unreinforced Masonry 2 0 1248 3RD ST PROMENADE 4291002009 Unreinforced Masonry 2 0 1318 3RD STREET PROMENADE 4291013003 Unreinforced Masonry 2 0 1319 3RD STREET PROMENADE 4291012016 Unreinforced Masonry 2 or one/w mezz 0 1 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1331 3RD STREET PROMENADE 4291012014 Unreinforced Masonry 1 0 1340 3RD STREET PROMENADE 4291013007 Unreinforced Masonry 2 0 1343 3RD STREET PROMENADE (1349)4291012012 Unreinforced Masonry 1 0 1344 3RD STREET PROMENADE 4291013008 Unreinforced Masonry 1 0 1348 3RD STREET PROMENADE 4291013009 Unreinforced Masonry 1 0 1351 3RD STREET PROMENADE 4291012011 Unreinforced Masonry 3 0 1410 3RD STREET PROMENADE (1412)4291016003 Unreinforced Masonry 1 0 1418 3RD STREET PROMENADE (BLDG 1)4291016005 Unreinforced Masonry 2 0 1424 3RD STREET PROMENADE (BLDG 2)4291016005 Unreinforced Masonry 2 0 1427 3RD STREET PROMENADE 4291017016 Unreinforced Masonry 2 0 1429 3RD STREET PROMENADE 4291017015 Unreinforced Masonry 1 0 1432 3RD STREET PROMENADE 4291016007 Unreinforced Masonry 1 0 1446 3RD STREET PROMENADE (1450)4291016010 Unreinforced Masonry 2 0 1452 3RD STREET PROMENADE 4291016011 Unreinforced Masonry 2 0 2103 3RD ST 4289013017 Soft Story 3 15 2214 3RD ST (2210)4289016027 Soft Story 4 58 2219 3RD ST (2219 3RD ST/311 STRAND ST)4289014010 Soft Story 2 8 2328 3RD ST 4289015001 Non-Ductile Concrete 4 17 2402 3RD ST 4287009022 Soft Story 3 24 2418 3RD ST 4287009004 Soft Story 2 4 2431 3RD ST 4287008037-047 Soft Story 4 11 2432 3RD ST 4287009006 Soft Story 2 3 2435 3RD ST 4287008012 Soft Story 4 10 2436 3RD ST 4287009013 Soft Story 2 4 2441 3RD ST 4287008013 Soft Story 3 7 2520 3RD ST 4287010005 Soft Story 3 18 2603 3RD ST 4287011021 Soft Story 3 10 2624 3RD ST 4287010026 Soft Story 3 8 2708 3RD ST 4287023002 Soft Story 3 6 2716 3RD ST 4287023030 Soft Story 3 14 2721 3RD ST 4287022007 Soft Story 2 6 2728 3RD ST 4287023009 Soft Story 3 9 2805 3RD ST 4287022010 Soft Story 3 8 2811 3RD ST 4287022013 Soft Story 3 11 2820 3RD ST 4287023014 Soft Story 3 6 2828 3RD ST 4287023031 Soft Story 3 19 2907 3RD ST 4287025011 Soft Story 4 11 2918 3RD ST 4287024005 Soft Story 2 3 3015 3RD ST 4287025019 Soft Story 2 7 3111 3RD ST 4287038025 Soft Story 3 20 227 4TH ST 4293001029 Soft Story 2 5 807 4TH ST 4292016023 Soft Story 3 1 817 4TH ST 4292016025 Soft Story 3 30 820 4TH ST 4292017004 Soft Story 3 7 824 4TH ST 4292017005 Soft Story 3 16 835 4TH ST 4292016018 Soft Story 3 22 908 4TH ST 4292018002 Unreinforced Masonry 2 0 914 4TH ST 4292018029 Soft Story 3 16 918 4TH ST 4292018004 Soft Story 3 14 921 4TH ST 4292015020 Soft Story 2 4 924 4TH ST 4292018005 Soft Story 3 14 928 4TH ST 4292018006 Soft Story 3 14 933 4TH ST 4292015018 Soft Story 3 10 943 4TH ST 4292015016 Soft Story 2 11 953 4TH ST 4292015014 Soft Story 4 14 1014 4TH ST 4292019079-089 Soft Story 3 11 1027 4TH ST 4292014016 Soft Story 2 11 1037 4TH ST 4292014014 Soft Story 2 8 1043 4TH ST 4292014013 Soft Story 2 6 1111 4TH ST 4292013015 Soft Story 2 17 2 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1114 4TH ST 4292020002 Soft Story 2 15 1234 4TH ST 4291003903 Non-Ductile Concrete 4 0 1301 4TH ST 4291011909 Concrete Tilt-Up 1 0 1320 4TH ST 4291012900 Non-Ductile Concrete 4 0 1330 4TH ST (1334)4291012005 Unreinforced Masonry 1 with mezanine 0 1342 4TH ST (1344)4291012007 Unreinforced Masonry 2 0 1422 4TH ST 4291017004 Non-Ductile Concrete 2 0 1424 4TH ST 4291017004 Steel Moment Frame 2 0 1437 4TH ST (1433)4291018026 Unreinforced Masonry 1 0 1443 4TH ST 4291018015 Unreinforced Masonry 2 0 1455 4TH ST 4291018014 Unreinforced Masonry 4 0 1501 4TH ST (1501-1515)4291025032 Unreinforced Masonry 3 0 1527 4TH ST 4291025900 Steel Moment Frame 2 0 1707 4TH ST 4290006905 Non-Ductile Concrete 8 0 1717 4TH ST 4290006904 Steel Moment Frame 3 0 1905 4TH ST (400 PICO BLVD)4289011046 Unreinforced Masonry 2 0 2002 4TH ST 4289013049-086 Soft Story 4 38 2015 4TH ST 4289010033 Soft Story 2 15 2110 4TH ST 4289013008 Soft Story 3 27 2120 4TH ST 4289013009 Soft Story 3 27 2216 4TH ST 4289014030-037 Soft Story 3 8 2233 4TH ST 4289008081-086 Soft Story 3 6 2311 4TH ST 4289007039-099 Soft Story 2 61 2407 4TH ST 4287007063 Soft Story 3 10 2417 4TH ST 4287007013 Soft Story 2 1 2423 4TH ST 4287007014 Soft Story 3 8 2427 4TH ST (2434 5TH ST)4287007038 Soft Story 3 30 2436 4TH ST 4287008009 Soft Story 3 10 2439 4TH ST 4287007025 Soft Story 3 10 2444 4TH ST 4287008098-107 Soft Story 3 10 2454 4TH ST 4287008030-035 Soft Story 4 6 2500 4TH ST 4287008049-058 Soft Story 3 10 2511 4TH ST 4287007004 Soft Story 2 3 2519 4TH ST 4287007047-058 Soft Story 3 12 2520 4TH ST (2518)4287008023 Soft Story 2 5 2522 4TH ST (2524)4287008024 Soft Story 2 3 2622 4TH ST 4287011020 Soft Story 2 13 2632 4TH ST (2632-2634 4TH ST)4287011026 Soft Story 2 6 2637 4TH ST 4287012010 Soft Story 3 4 2638 4TH ST 4287011027 Soft Story 2 6 2641 4TH ST 4287012064-069 Soft Story 3 6 2719 4TH ST 4287021005 Soft Story 2 4 2731 4TH ST (2731 4TH ST/409 RAYMOND AVE)4287021007 Soft Story 2 5 2709 4TH ST 4287021003 Soft Story 2 0 2928 4TH ST 4287025023 Soft Story 3 43 3104 4TH ST 4287038031 Soft Story 4 17 3111 4TH ST 4287038032 Soft Story 4 60 3120 4TH ST 4287038029 Soft Story 3 24 804 5TH ST 4292016001 Soft Story 2 4 807 5TH ST 4292009025 Soft Story 3 11 808 5TH ST 4292016002 Soft Story 3 10 811 5TH ST 4292009024 Soft Story 2 2 814 5TH ST 4292016041-050 Soft Story 3 10 818 5TH ST 4292016004 Soft Story 2 10 833 5TH ST 4292009027 Soft Story 3 24 834 5TH ST (834-836 5TH ST)4292016007 Soft Story 2 5 837 5TH ST 4292009019 Soft Story 2 6 838 5TH ST 4292016008 Soft Story 3 11 844 5TH ST 4292016009 Soft Story 2 10 3 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 917 5TH ST 4292010020 Soft Story 2 10 924 5TH ST 4292015041-049 4292015051 Soft Story 3 10 937 5TH ST 4292010083-092 Soft Story 2 10 943 5TH ST 4292010015 Soft Story 2 10 947 5TH ST 4292010014 Soft Story 2 6 953 5TH ST 4292010013 Soft Story 2 10 1021 5TH ST 4292011081-101 Soft Story 3 21 1024 5TH ST 4292014029-038 Soft Story 3 10 1030 5TH ST 4292014006 Soft Story 2 7 1055 5TH ST 4292011023 Soft Story 2 9 1110 5TH ST 4292013002 Soft Story 3 20 1342 5TH ST 4291011907 Non-Ductile Concrete 3 0 1407 5TH ST 4291019023 Non-Ductile Concrete 5 0 1530 5TH ST 4291025034 Non-Ductile Concrete 6 126 2011 5TH ST 4289009031 Soft Story 2 5 2201 5TH ST 4289008043 Soft Story 2 16 2209 5TH ST 4289008033 Soft Story 2 2 2309 5TH ST (2309-2317 5TH, 2310-2312 6TH)4289007101-120 Soft Story 2 20 2322 5TH ST 4289007035 Soft Story 3 20 2402 5TH ST 4287007046 Soft Story 3 6 2424 5TH ST 4287007017 Soft Story 2 3 2438 5TH ST 4287007031 Soft Story 3 3 2616 5TH ST 4287012044-062 Soft Story 2 19 2624 5TH ST 4287012027 Soft Story 2 6 2628 5TH ST 4287012028 Soft Story 2 10 2635 5TH ST 4287013009 Soft Story 2 9 3101 5TH ST 4287037041-053 Soft Story 3 13 3113 5TH ST 4287037004 Soft Story 2 4 801 6TH ST (801 6TH ST/602-612 MONTANA AVE)4292008021 Soft Story 2 7 808 6TH ST 4292009003 Soft Story 2 10 814 6TH ST 4292009102-109 Soft Story 3 8 828 6TH ST 4292009007 Soft Story 3 10 844 6TH ST 4292009010 Soft Story 4 12 847 6TH ST 4292008013 Soft Story 2 9 852 6TH ST (852 6TH ST/531 IDAHO AVE)4292009012 Soft Story 2 2 855 6TH ST 4292008012 Soft Story 3 21 913 6TH ST 4292007024 Soft Story 2 10 917 6TH ST 4292007023 Soft Story 3 11 918 6TH ST 4292010003 Soft Story 3 10 927 6TH ST 4292007021 Soft Story 2 10 928 6TH ST 4292010005 Soft Story 4 12 933 6TH ST 4292007020 Soft Story 3 11 943 6TH ST 4292007018 Soft Story 2 10 944 6TH ST 4292010008 Soft Story 3 9 947 6TH ST 4292007017 Soft Story 2 10 952 6TH ST 4292010094-101 Soft Story 2 8 1002 6TH ST (1002 6TH ST/522 WASHINGTON AVE)4292011001 Soft Story 3 10 1026 6TH ST (1028)4292011006 Soft Story 2 10 1042 6TH ST 4292011026 Soft Story 3 16 1114 6TH ST 4292012004 Soft Story 4 5 1120 6TH ST 4292012005 Soft Story 2 10 1133 6TH ST 4292005016 Soft Story 2 6 1137 6TH ST 4292005015 Soft Story 3 16 1233 6TH ST 4291006024 Non-Ductile Concrete 13 150 1250 6TH ST 4291005011 Steel Moment Frame 4 0 1332 6TH ST 4291010028 Steel Moment Frame 3 0 1547 6TH ST 4291023011 Soft Story 2 1 1901 6TH ST 4289003026 Soft Story 3 16 1920 6TH ST 4289011044 Non-Ductile Concrete 4 103 4 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 2036 6TH ST 4289009006 Soft Story 3 4 2117 6TH ST 4289005036 Soft Story 2 3 2202 6TH ST (2202 6TH ST/520 PACIFIC ST)4289008021 Soft Story 2 5 2216 6TH ST 4289008024 Soft Story 3 5 2302 6TH ST (2302-06 6TH ST/520 STRAND ST)4289007122-131 Soft Story 3 10 2319 6TH ST 4289006012 Soft Story 3 10 2321 6TH ST (2321 6TH ST/2414 BEVERLEY AVE)4289006003 Soft Story 2 3 2411 6TH ST 4287005015 Soft Story 3 1 2613 6TH ST (2613-2615 6TH ST)4287014027-038 Soft Story 3 12 2616 6TH ST 4287013023 Soft Story 3 8 2621 6TH ST (2625)4287014044-053 Soft Story 2 10 2628 6TH ST 4287013026 Soft Story 3 10 2647 6TH ST 4287014055-078 Soft Story 3 24 2721 6TH ST 4287019029 Soft Story 3 22 2727 6TH ST 4287019027 Soft Story 3 29 2813 6TH ST 4287019028 Soft Story 2 20 2815 6TH ST 4287019021 Soft Story 3 6 2909 6TH ST (2910 HIGHLAND AVE)4287026041 Soft Story 2 4 2917 6TH ST 4287026038 Soft Story 2 1 3109 6TH ST 4287037020 Soft Story 2 2 3115 6TH ST 4287037037-040 Soft Story 3 4 3125 6TH ST 4287037024 Soft Story 2 3 3129 6TH ST 4287037025 Soft Story 2 3 817 7TH ST 4292001021 Soft Story 2 6 818 7TH ST 4292008004 Soft Story 3 10 822 7TH ST 4292008005 Soft Story 2 4 827 7TH ST 4292001019 Soft Story 2 11 834 7TH ST 4292008007 Soft Story 3 10 838 7TH ST 4292008008 Soft Story 2 11 848 7TH ST 4292008010 Soft Story 2 10 907 7TH ST 4292002022 Soft Story 3 10 914 7TH ST 4292007004 Soft Story 3 11 915 7TH ST (915-917 7TH ST)4292002020 Soft Story 2 5 918 7TH ST 4292007005 Soft Story 3 12 921 7TH ST (921-923 7TH ST)4292002019 Soft Story 2 8 924 7TH ST 4292007006 Soft Story 3 10 933 7TH ST 4292002017 Soft Story 2 10 942 7TH ST 4292007027 Soft Story 3 9 947 7TH ST 4292002014 Soft Story 2 7 948 7TH ST 4292007011 Soft Story 3 11 954 7TH ST 4292007012 Soft Story 3 10 1008 7TH ST 4292006002 Soft Story 3 11 1012 7TH ST 4292006029-048 Soft Story 3 20 1038 7TH ST 4292006008 Soft Story 3 10 1044 7TH ST 4292006009 Soft Story 3 10 1112 7TH ST 4292005027 Non-Ductile Concrete 17 285 1128 7TH ST 4292005005 Soft Story 4 15 1133 7TH ST (BLDG 1)4292004900 Concrete Tilt-Up 1 0 1133 7TH ST (BLDG 2)4292004900 Concrete Tilt-Up 1 0 1212 7TH ST 4291006026 Non-Ductile Concrete 4 0 1518 7TH ST 4291023003 Soft Story 2 10 1540 7TH ST 4291023006 Soft Story 3 0 1653 7TH ST 4290002900 Steel Moment Frame 2 0 1660 7TH ST 4290009905 Steel Moment Frame 2 0 1811 7TH ST 4290004003 Soft Story 3 11 1817 7TH ST 4290004004 Soft Story 3 10 1823 7TH ST 4290004005 Soft Story 3 10 1835 7TH ST 4290004031-037 Soft Story 3 7 1843 7TH ST 4290004010 Soft Story 3 11 1851 7TH ST 4290004011 Soft Story 2 11 5 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1857 7TH ST 4290004012 Soft Story 2 7 2111 7TH ST 4289002011 Soft Story 2 10 2418 7TH ST 4287004013 Soft Story 3 7 2518 7TH ST 4287003002 Soft Story 2 1 2534 7TH ST 4287003010 Soft Story 2 4 2602 7TH ST (2602-2614 7TH ST)4287015047-050 Soft Story 2 4 611 9TH ST 4280023046-050 Soft Story 2 5 627 9TH ST 4280023022 Soft Story 2 5 637 9TH ST 4280023024 Soft Story 2 5 711 9TH ST 4280023026 Soft Story 2 6 813 9TH ST 4281031022 Soft Story 2 10 828 9TH ST 4281032006 Soft Story 2 5 833 9TH ST 4281031018 Soft Story 2 6 837 9TH ST 4281031017 Soft Story 2 6 844 9TH ST 4281032009 Soft Story 3 10 847 9TH ST 4281031015 Soft Story 2 14 854 9TH ST 4281032011 Soft Story 3 10 906 9TH ST 4281033001 Soft Story 3 14 912 9TH ST 4281033003 Soft Story 3 11 919 9TH ST 4281030021 Soft Story 2 10 923 9TH ST 4281030020 Soft Story 2 10 924 9TH ST 4281033005 Soft Story 3 10 928 9TH ST 4281033006 Soft Story 3 10 932 9TH ST 4281033007 Soft Story 3 10 943 9TH ST 4281030045-054 Soft Story 2 10 1018 9TH ST 4281034006 Soft Story 3 10 1024 9TH ST 4281034007 Soft Story 2 11 1034 9TH ST 4281034009 Soft Story 2 10 1035 9TH ST (1033-1037 9TH ST)4281029039-043 4281029046-049 4281029066 Soft Story 3 10 1041 9TH ST 4281029015 Soft Story 2 10 1047 9TH ST 4281029014 Soft Story 2 3 1048 9TH ST 4281034065-073 Soft Story 3 9 1117 9TH ST (1115-1117 9TH ST)4281028031 Soft Story 3 21 1118 9TH ST 4281035004 Soft Story 2 10 1122 9TH ST 4281035005 Soft Story 3 10 1130 9TH ST 4281035045-054 Soft Story 3 10 1142 9TH ST 4281035028 Soft Story 3 20 1217 9TH ST 4282008019 Soft Story 2 10 1218 9TH ST 4282009032-043 Soft Story 3 12 1228 9TH ST 4282009006 Soft Story 3 10 1236 9TH ST 4282009007 Soft Story 3 16 1239 9TH ST 4282008031-037 Soft Story 3 7 1241 9TH ST 4282008014 Soft Story 2 10 1242 9TH ST 4282009045-052 Soft Story 3 8 1249 9TH ST 4282008013 Soft Story 2 10 1254 9TH ST 4282009025 Soft Story 3 11 1257 9TH ST 4282008012 Soft Story 3 5 1264 9TH ST 4282009026 Soft Story 3 11 1303 9TH ST 4282011027 Soft Story 2 3 1307 9TH ST 4282011026 Soft Story 2 11 1313 9TH ST 4282011032 Soft Story 3 22 1324 9TH ST 4282010007 Soft Story 2 10 1325 9TH ST 4282011043-052 Soft Story 3 10 1333 9TH ST 4282011021 Soft Story 2 10 1334 9TH ST 4282010009 Soft Story 2 7 1340 9TH ST 4282010010 Soft Story 2 6 1341 9TH ST 4282011019 Soft Story 2 0 1432 9TH ST 4282027007 Soft Story 2 10 1433 9TH ST 4282026016 Soft Story 2 10 6 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1437 9TH ST 4282026015 Soft Story 2 7 1438 9TH ST 4282027034 Soft Story 2 0 1445 9TH ST 4282026013 Soft Story 2 11 1455 9TH ST 4282026012 Soft Story 2 25 1517 9TH ST 4282029016 Soft Story 2 6 1527 9TH ST 4282029014 Soft Story 3 8 1541 9TH ST 4282029011 Soft Story 2 4 1743 9TH ST 4283018026 Soft Story 2 8 1748 9TH ST 4283019004 Soft Story 2 7 1802 9TH ST 4283020003 Soft Story 2 2 1819 9TH ST 4283021005 Soft Story 2 5 1834 9TH ST 4283020047-051 Soft Story 2 5 1837 9TH ST 4283021009 Soft Story 2 6 1838 9TH ST 4283020027 Soft Story 2 7 1843 9TH ST 4283021020 Soft Story 2 10 1846 9TH ST 4283020053-057 Soft Story 2 5 1855 9TH ST 4283021021 Soft Story 2 11 1860 9TH ST 4283020040 Soft Story 2 15 820 10TH ST 4281031026 Soft Story 2 5 823 10TH ST 4281024021 Soft Story 2 6 824 10TH ST 4281031004 Soft Story 3 10 827 10TH ST 4281024020 Soft Story 3 15 828 10TH ST 4281031005 Soft Story 3 10 833 10TH ST 4281024019 Soft Story 3 10 837 10TH ST 4281024047-056 Soft Story 3 10 848 10TH ST 4281031009 Soft Story 3 10 854 10TH ST (854 10TH ST/929 IDAHO AVE)4281031010 Soft Story 3 4 912 10TH ST 4281030025 Soft Story 2 7 924 10TH ST 4281030006 Soft Story 3 10 928 10TH ST 4281030007 Soft Story 2 10 931 10TH ST 4281025078-081 Soft Story 3 4 941 10TH ST 4281025015 Soft Story 2 9 942 10TH ST 4281030010 Soft Story 3 11 1009 10TH ST 4281026015 Soft Story 2 5 1017 10TH ST 4281026023 Soft Story 2 13 1027 10TH ST 4281026033-037 Soft Story 3 5 1022 10TH ST 4281029061-065 Soft Story 3 6 1028 10TH ST 4281029006 Soft Story 2 5 1031 10TH ST 4281026010 Soft Story 2 1 1037 10TH ST 4281026009 Soft Story 3 11 1038 10TH ST 4281029008 Soft Story 2 6 1044 10TH ST 4281029033-038 Soft Story 3 6 1048 10TH ST 4281029068-071 Soft Story 2 7 1117 10TH ST 4281027021 Soft Story 2 11 1118 10TH ST 4281028004 Soft Story 2 2 1122 10TH ST 4281028005 Soft Story 2 6 1123 10TH ST 4281027078-085 Soft Story 2 8 1133 10TH ST 4281027032 Soft Story 3 21 1134 10TH ST 4281028007 Soft Story 3 11 1140 10TH ST 4281028008 Soft Story 2 10 1143 10TH ST 4281027016 Soft Story 3 9 1144 10TH ST 4281028096-105 Soft Story 3 10 1221 10TH ST 4282007019 Soft Story 2 10 1250 10TH ST 4282008023 Soft Story 3 22 1258 10TH ST 4282008009 Soft Story 3 11 1310 10TH ST 4282011003 Soft Story 3 10 1314 10TH ST 4282011004 Soft Story 2 6 1328 10TH ST 4282011007 Soft Story 2 1 1330 10TH ST 4282011008 Soft Story 2 5 1428 10TH ST 4282026005 Soft Story 2 7 7 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1437 10TH ST 4282025019 Soft Story 2 5 1444 10TH ST 4282026008 Soft Story 2 4 1450 10TH ST 4282026022 Steel Moment Frame 4 0 1518 10TH ST 4282029003 Soft Story 3 11 1525 10TH ST 4282030027 Soft Story 3 20 1531 10TH ST 4282030017 Soft Story 2 7 1534 10TH ST 4282029006 Soft Story 3 10 1643 10TH ST 4283005009 Non-Ductile Concrete 1 0 1743 10TH ST 4283017024 Soft Story 2 4 1749 10TH ST 4283017021 Soft Story 2 5 1814 10TH ST 4283022004 Soft Story 2 5 1833 10TH ST 4283023023 Soft Story 2 7 1856 10TH ST 4283022012 Soft Story 2 6 2007 10TH ST 4284015001 Soft Story 2 4 2010 10TH ST (2010-2012 10TH ST)4284002014 Soft Story 2 3 2220 10TH ST (2220-2226 10TH ST)4284004013 Soft Story 2 4 2306 10TH ST (2302-2306 10TH ST)4284005014 Soft Story 2 4 2519 10TH ST (2519-2525 10TH ST)4284009010 Soft Story 2 4 811 11TH ST 4281023024 Soft Story 2 7 818 11TH ST 4281024005 Soft Story 3 10 824 11TH ST 4281024006 Soft Story 2 10 828 11TH ST 4281024007 Soft Story 3 10 832 11TH ST 4281024008 Soft Story 2 12 837 11TH ST 4281023063-072 Soft Story 2 10 843 11TH ST 4281023073-082 Soft Story 2 10 848 11TH ST 4281024011 Soft Story 2 1 908 11TH ST 4281025002 Soft Story 3 6 911 11TH ST 4281022025 Soft Story 2 5 912 11TH ST 4281025003 Soft Story 3 10 918 11TH ST 4281025004 Soft Story 3 10 921 11TH ST 4281022023 Soft Story 2 3 924 11TH ST 4281025005 Soft Story 2 6 933 11TH ST (927-933 11TH ST)4281022044-063 Soft Story 3 20 937 11TH ST 4281022065-075 Soft Story 2 11 938 11TH ST 4281025008 Soft Story 2 5 944 11TH ST 4281025028-037 Soft Story 3 10 948 11TH ST 4281025010 Soft Story 3 1 953 11TH ST 4281022017 Soft Story 2 7 954 11TH ST 4281025011 Soft Story 2 5 958 11TH ST 4281025012 Soft Story 2 4 1011 11TH ST 4281021022 Soft Story 2 0 1043 11TH ST 4281021061-065 Soft Story 3 5 1047 11TH ST 4281021034 Soft Story 2 10 1103 11TH ST (1103-1107 11TH ST)4281020022 Soft Story 2 3 1111 11TH ST 4281020021 Soft Story 3 10 1117 11TH ST 4281020020 Soft Story 3 11 1118 11TH ST 4281027005 Soft Story 2 0 1124 11TH ST 4281027006 Soft Story 2 11 1128 11TH ST 4281027058-067 Soft Story 3 10 1134 11TH ST 4281027008 Soft Story 4 11 1137 11TH ST 4281020016 Soft Story 3 11 1138 11TH ST 4281027009 Soft Story 2 10 1215 11TH ST 4282006023 Soft Story 2 7 1218 11TH ST 4282007004 Soft Story 2 3 1221 11TH ST 4282006022 Soft Story 2 4 1227 11TH ST 4282006021 Soft Story 2 10 1234 11TH ST 4282007007 Soft Story 3 11 1244 11TH ST 4282007024 Soft Story 3 20 1247 11TH ST 4282006017 Soft Story 2 9 1253 11TH ST 4282006054-058 Soft Story 3 5 8 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1315 11TH ST 4282013020 Soft Story 2 11 1319 11TH ST 4282013026-036 Soft Story 2 11 1323 11TH ST 4282013018 Soft Story 2 10 1327 11TH ST 4282013017 Soft Story 2 7 1425 11TH ST 4282024028 Soft Story 3 20 1428 11TH ST (1428-1424 11TH ST)4282025007 Soft Story 2 10 1433 11TH ST 4282024021 Soft Story 2 10 1437 11TH ST 4282024020 Soft Story 2 8 1528 11TH ST 4282030006 Soft Story 2 6 1538 11TH ST 4282030008 Soft Story 3 11 1846 11TH ST (1846-1848 11TH ST)4283024011 Soft Story 2 3 1908 11TH ST 4283024007 Soft Story 2 6 1917 11TH ST 4283025021-026 Soft Story 2 6 2602 11TH ST (2602-2612 11TH ST)4285001024 Soft Story 2 6 2626 11TH ST 4285001031 Soft Story 2 7 2630 11TH ST 4285001035-040 Soft Story 3 6 2702 11TH ST (2702-2706 11TH ST)4285001058-063 Soft Story 2 6 2704 11TH ST 4285001017 Soft Story 2 6 2912 11TH ST 4285027057 4285027059-063 Soft Story 2 6 2920 11TH ST 4285027036-041 Soft Story 3 6 723 12TH ST 4280026021 Soft Story 2 4 814 12TH ST 4281023004 Soft Story 3 10 817 12TH ST 4281016017 Soft Story 3 11 818 12TH ST 4281023005 Soft Story 3 10 827 12TH ST 4281016015 Soft Story 2 6 837 12TH ST 4281016013 Soft Story 2 4 838 12TH ST 4281023009 Soft Story 2 4 847 12TH ST 4281016011 Soft Story 2 3 853 12TH ST 4281016054-059 Soft Story 2 6 907 12TH ST 4281017109-116 Soft Story 3 8 908 12TH ST 4281022006 Soft Story 2 4 918 12TH ST 4281022008 Soft Story 3 10 947 12TH ST 4281017015 Soft Story 2 9 1013 12TH ST 4281018022 Soft Story 2 10 1028 12TH ST 4281021006 Soft Story 3 10 1034 12TH ST 4281021007 Soft Story 2 5 1044 12TH ST 4281021009 Soft Story 3 10 1050 12TH ST 4281021010 Soft Story 2 10 1111 12TH ST 4281019018 Soft Story 2 7 1117 12TH ST 4281019017 Soft Story 3 11 1123 12TH ST 4281019016 Soft Story 2 7 1124 12TH ST 4281020005 Soft Story 2 4 1128 12TH ST 4281020006 Soft Story 3 11 1132 12TH ST 4281020007 Soft Story 2 10 1137 12TH ST 4281019013 Soft Story 3 11 1138 12TH ST 4281020044-054 Soft Story 3 11 1144 12TH ST 4281020055 Soft Story 3 17 1224 12TH ST 4282006005 Soft Story 3 10 1225 12TH ST 4282005030 Soft Story 2 10 1229 12TH ST 4282005021 Soft Story 3 12 1239 12TH ST 4282005019 Soft Story 3 11 1243 12TH ST 4282005018 Soft Story 3 10 1247 12TH ST 4282005017 Soft Story 3 10 1257 12TH ST 4282005031 Soft Story 3 16 1304 12TH ST 4282013001 Soft Story 3 3 1317 12TH ST 4282014030-039 Soft Story 3 10 1327 12TH ST 4282014018 Soft Story 2 10 1328 12TH ST 4282013006 Soft Story 2 7 1424 12TH ST (1424-1428 12TH ST)4282024027 Soft Story 3 20 9 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1434 12TH ST 4282024008 Soft Story 2 10 1438 12TH ST 4282024009 Soft Story 2 1 1457 12TH ST 4282023011 Soft Story 2 3 1507 12TH ST 4282032022 Soft Story 3 13 1511 12TH ST 4282032028 Soft Story 2 4 1511 12TH ST 4282032027 Soft Story 2 2 1518 12TH ST 4282031007 Soft Story 2 6 1519 12TH ST 4282032019 Soft Story 2 10 1521 12TH ST 4282032018 Soft Story 2 10 1524 12TH ST 4282031008 Soft Story 2 6 1528 12TH ST 4282031009 Soft Story 3 11 1549 12TH ST (1545)4282032032 Unreinforced Masonry 1 0 1801 12TH ST (1801 12TH ST/1210-1212 MICHIGAN AVE)4283027001 Soft Story 2 6 1804 12TH ST 4283026019 Soft Story 2 6 1807 12TH ST (1807-1809 12TH ST)4283027002 Soft Story 2 2 1813 12TH ST 4283027003 Soft Story 2 6 1820 12TH ST 4283026016 Soft Story 2 6 1840 12TH ST 4283026012 Soft Story 2 5 1844 12TH ST (1844-1846 12TH ST)4283026011 Soft Story 2 6 1853 12TH ST 4283027011 Soft Story 2 4 1901 12TH ST 4283027012 Soft Story 2 3 1908 12TH ST 4283026007 Soft Story 2 6 1914 12TH ST 4283026006 Soft Story 2 2 1918 12TH ST 4283026005 Soft Story 2 1 1922 12TH ST 4283026004 Soft Story 2 2 1934 12TH ST 4283026002 Soft Story 2 6 1943 12TH ST 4283027020 Soft Story 2 4 813 14TH ST 4281009021 Soft Story 2 7 814 14TH ST 4281015004 Soft Story 2 4 817 14TH ST 4281009020 Soft Story 2 7 844 14TH ST 4281015009 Soft Story 2 5 848 14TH ST 4281015010 Soft Story 2 8 858 14TH ST 4281015011 Soft Story 3 6 907 14TH ST (907-909 14TH ST)4281010022 Soft Story 2 6 922 14TH ST 4281014054-074 Soft Story 3 21 925 14TH ST 4281010028-059 Soft Story 3 32 945 14TH ST 4281010015 Soft Story 2 7 948 14TH ST 4281014009 Soft Story 2 10 1008 14TH ST 4281013002 Soft Story 2 4 1014 14TH ST 4281013003 Soft Story 2 10 1024 14TH ST 4281013004 Soft Story 2 4 1026 14TH ST 4281013005 Soft Story 2 5 1028 14TH ST 4281013006 Soft Story 2 10 1034 14TH ST 4281013007 Soft Story 3 10 1048 14TH ST 4281013010 Soft Story 3 10 1114 14TH ST (1114-1120 14TH ST)4281012002 Soft Story 2 7 1115 14TH ST (1111-1115 14TH ST)4281011029 Soft Story 2 22 1121 14TH ST 4281011018 Soft Story 2 4 1127 14TH ST 4281011017 Soft Story 2 5 1131 14TH ST 4281011016 Soft Story 3 8 1137 14TH ST 4281011015 Soft Story 2 10 1218 14TH ST 4282004003 Soft Story 3 12 1223 14TH ST 4282003017 Soft Story 2 4 1234 14TH ST 4282004006 Soft Story 2 11 1248 14TH ST 4282004009 Soft Story 2 4 1254 14TH ST 4282004010 Soft Story 2 4 1307 14TH ST 4282016022 Soft Story 2 6 1319 14TH ST 4282016020 Soft Story 2 7 1323 14TH ST 4282016019 Soft Story 3 11 1332 14TH ST 4282015008 Soft Story 2 5 10 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1333 14TH ST 4282016030-040 Soft Story 3 11 1338 14TH ST 4282015009 Soft Story 3 12 1339 14TH ST (1339-1343 14TH ST)4282016016 Soft Story 2 16 1344 14TH ST 4282015010 Soft Story 2 11 1417 14TH ST 4282021018 Soft Story 3 11 1423 14TH ST (1423-1425 14TH ST)4282021017 Soft Story 2 6 1424 14TH ST 4282022005 Soft Story 3 10 1427 14TH ST (1427-1429 14TH ST)4282021016 Soft Story 3 8 1428 14TH ST 4282022006 Soft Story 3 10 1438 14TH ST 4282022008 Soft Story 3 10 1453 14TH ST (1409 BROADWAY)4282021013 Unreinforced Masonry 1 0 1514 14TH ST (1514-1518 14TH ST)4282033021 Soft Story 3 36 1557 14TH ST 4282034010 Non-Ductile Concrete 2 0 1750 14TH ST 4283014024 Soft Story 2 0 1847 14TH ST 4283031900 Concrete Tilt-Up 2 0 2020 14TH ST 4284033014 Soft Story 2 26 2028 14TH ST 4284033012 Soft Story 2 8 2219 14TH ST 4284037022 Soft Story 2 1 2315 14TH ST 4284038014 Soft Story 3 11 2319 14TH ST 4284038015 Soft Story 3 13 2323 14TH ST 4284038016 Soft Story 2 11 2505 14TH ST 4284026002 Soft Story 2 3 2511 14TH ST 4284026003 Soft Story 2 3 2525 14TH ST 4284026024-030 Soft Story 2 7 2601 14TH ST (2601 14TH ST/1404 OCEAN PARK BLVD)4285004011 Soft Story 2 6 2618 14TH ST 4285003013 Soft Story 2 4 827 15TH ST 4281008019 Soft Story 2 6 828 15TH ST 4281009006 Soft Story 2 6 833 15TH ST 4281008018 Soft Story 2 6 907 15TH ST 4281007022 Soft Story 2 9 908 15TH ST 4281010002 Soft Story 2 6 921 15TH ST 4281007020 Soft Story 2 6 934 15TH ST 4281010007 Soft Story 2 6 938 15TH ST 4281010008 Soft Story 2 5 1101 15TH ST (1101-1109 11TH ST)4281005054-058 Soft Story 2 5 1119 15TH ST 4281005047-052 Soft Story 2 6 1127 15TH ST 4281005035-040 Soft Story 2 6 1132 15TH ST 4281011007 Soft Story 2 6 1228 15TH ST 4282003003 Soft Story 2 10 1232 15TH ST 4282003004 Soft Story 2 17 1304 15TH ST 4282016026 Non-Ductile Concrete 4 0 1307 15TH ST 4282017034 Soft Story 2 11 1423 15TH ST 4282020020 Soft Story 2 11 1424 15TH ST 4282021005 Soft Story 2 10 1427 15TH ST 4282020019 Soft Story 3 10 1428 15TH ST 4282021006 Soft Story 3 11 1438 15TH ST 4282021008 Soft Story 2 7 1444 15TH ST 4282021009 Soft Story 2 7 1530 15TH ST 4282034006 Soft Story 2 5 1754 15TH ST 4283013010 Soft Story 2 6 825 16TH ST 4281001020 Soft Story 2 5 828 16TH ST 4281008006 Soft Story 2 6 833 16TH ST 4281001018 Soft Story 2 6 843 16TH ST 4281001030 Soft Story 2 13 847 16TH ST 4281001015 Soft Story 2 6 848 16TH ST 4281008010 Soft Story 2 5 854 16TH ST 4281008011 Soft Story 2 7 917 16TH ST 4281002022 Soft Story 2 6 921 16TH ST 4281002021 Soft Story 2 6 922 16TH ST 4281007045-050 Soft Story 2 6 11 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 928 16TH ST 4281007006 Soft Story 2 7 934 16TH ST 4281007007 Soft Story 2 7 935 16TH ST (931-935 16TH ST)4281002019 Soft Story 2 5 948 16TH ST 4281007072-076 Soft Story 2 5 952 16TH ST 4281007011 Soft Story 2 6 1009 16TH ST (1007-1009 16TH ST)4281003020 Soft Story 2 4 1101 16TH ST (1101-1107 16TH ST)4281004022 Soft Story 2 4 1128 16TH ST 4281005006 Soft Story 2 4 1132 16TH ST 4281005007 Soft Story 2 6 1133 16TH ST 4281004017 Soft Story 2 6 1138 16TH ST 4281005028-033 Soft Story 2 6 1139 16TH ST 4281004016 Soft Story 2 6 1245 16TH ST 4282001033 Steel Moment Frame 3 0 1311 16TH ST 4282018900 Non-Ductile Concrete 4 0 1318 16TH ST 4282017004 Soft Story 4 18 1324 16TH ST 4282017005 Soft Story 2 4 1421 16TH ST (1419-1421 16TH ST)4282019020 Soft Story 3 8 1432 16TH ST 4282020007 Soft Story 2 10 1528 16TH ST 4282035006 Soft Story 2 3 1651 16TH ST 4283010900 Concrete Tilt-Up 2 0 1748 16TH ST 4283012024 Soft Story 2 4 1753 16TH ST 4283011026 Soft Story 2 2 1753 16TH ST 4283011025 Soft Story 2 2 2318 16TH ST 4284038031 Soft Story 3 12 745 17TH ST 4279016021 Soft Story 2 4 816 17TH ST (816-818 17TH ST)4281001004 Soft Story 2 6 853 17TH ST 4277008024 Soft Story 2 3 855 17TH ST (1709 IDAHO AVE)4277008143-149 Soft Story 2 7 912 17TH ST 4281002063-068 Soft Story 2 6 918 17TH ST 4281002056-061 Soft Story 2 6 932 17TH ST (932-934 17TH ST)4281002026 Soft Story 2 6 944 17TH ST 4281002030-035 Soft Story 2 6 951 17TH ST 4277009024 Soft Story 2 7 952 17TH ST 4281002012 Soft Story 2 5 960 17TH ST 4281002013 Soft Story 3 6 1008 17TH ST 4281003044 Soft Story 2 6 1012 17TH ST 4281003057-062 Soft Story 2 6 1111 17TH ST 4276010013 Soft Story 2 6 1117 17TH ST 4276010014 Soft Story 2 5 1123 17TH ST 4276010015 Soft Story 2 6 1124 17TH ST 4281004005 Soft Story 2 5 1135 17TH ST (1135-1137 17TH ST)4276010068-072 Soft Story 2 5 1141 17TH ST 4276010049-053 Soft Story 3 5 1144 17TH ST (1144-1148 17TH ST)4281004040-052 Soft Story 2 13 1234 17TH ST 4282001006 Soft Story 2 5 1242 17TH ST 4282001008 Soft Story 2 6 1247 17TH ST 4276011012 Soft Story 3 6 1412 17TH ST 4282019003 Soft Story 2 12 1417 17TH ST 4275011022 Soft Story 2 6 1427 17TH ST 4275011020 Soft Story 2 5 1524 17TH ST 4282036005 Soft Story 2 7 1753 17TH ST 4274027005 Soft Story 3 8 1813 17TH ST 4274013006 Soft Story 2 6 1836 17TH ST 4283032007 Soft Story 2 7 1927 17TH ST 4284014017 Soft Story 2 2 1943 17TH ST 4274015001 Soft Story 2 7 231 18TH ST 4279011016 Soft Story 2 0 752 18TH ST (748-752 18TH ST)4279016001 Soft Story 2 4 811 18TH ST (813)4277008062 Soft Story 2 4 823 18TH ST 4277008064 Soft Story 2 5 12 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 824 18TH ST 4277008005 Soft Story 2 6 827 18TH ST 4277008065 Soft Story 2 6 843 18TH ST 4277008068 Soft Story 2 7 847 18TH ST 4277008069 Soft Story 2 6 848 18TH ST 4277008010 Soft Story 2 7 853 18TH ST 4277008070 Soft Story 3 7 907 18TH ST 4277010133 Soft Story 2 5 908 18TH ST 4277009079-084 Soft Story 2 6 914 18TH ST 4277009003 Soft Story 2 4 918 18TH ST (916-918 18TH ST)4277009004 Soft Story 2 6 923 18TH ST 4277010016 Soft Story 3 6 927 18TH ST 4277010041 Soft Story 2 6 928 18TH ST 4277009006 Soft Story 2 5 941 18TH ST 4277010038 Soft Story 2 6 948 18TH ST 4277009010 Soft Story 2 5 952 18TH ST 4277009011 Soft Story 3 6 953 18TH ST 4277010045 Soft Story 2 4 958 18TH ST 4277009031-037 Soft Story 3 7 1009 18TH ST 4277026027 Soft Story 2 4 1015 18TH ST 4277026015 Soft Story 2 6 1020 18TH ST 4277027018 Soft Story 2 5 1025 18TH ST 4277026017 Soft Story 2 5 1028 18TH ST 4277027016 Soft Story 2 5 1032 18TH ST 4277027015 Soft Story 2 6 1037 18TH ST 4277026078-086 Soft Story 2 9 1040 18TH ST 4277027013 Soft Story 2 5 1048 18TH ST 4277027063-069 Soft Story 2 7 1052 18TH ST (1052-1054 18TH ST/1719 CALIFORNIA AVE)4277027010 Soft Story 2 15 1111 18TH ST 4276009003 Soft Story 2 4 1122 18TH ST 4276010039 Soft Story 2 21 1127 18TH ST 4276009006 Soft Story 2 7 1130 18TH ST (1130-1132 18TH ST)4276010008 Soft Story 2 3 1135 18TH ST (1133-1135 18TH ST)4276009007 Soft Story 2 3 1231 18TH ST 4276012037-042 Soft Story 2 6 1243 18TH ST 4276012014 Soft Story 2 3 1253 18TH ST 4276012051-055 Soft Story 2 5 1310 18TH ST 4276030002 Soft Story 2 6 1313 18TH ST 4276029050-055 Soft Story 2 6 1323 18TH ST 4276029019 Soft Story 2 4 1345 18TH ST 4276029015 Soft Story 2 7 1417 18TH ST 4275010021 Soft Story 3 6 1423 18TH ST 4275010020 Soft Story 3 6 1524 18TH ST 4275012029 Soft Story 2 6 1802 18TH ST 4274013001 Soft Story 2 5 1823 18TH ST 4274012009 Soft Story 2 3 1837 18TH ST 4274012015 Soft Story 2 7 1844 18TH ST 4274013017 Soft Story 2 4 1928 18TH ST 4274014007 Soft Story 2 5 1958 18TH ST 4274015012 Soft Story 2 6 1967 18TH ST 4274017008 Soft Story 2 7 752 19TH ST (1821 MONTANA AVE)4279015020-026 Soft Story 2 7 814 19TH ST 4277008055 Soft Story 2 7 819 19TH ST 4277006053-058 Soft Story 2 6 822 19TH ST (822-828 19TH ST)4277008072-081 Soft Story 3 10 823 19TH ST 4277006017 Soft Story 2 6 833 19TH ST 4277006019 Soft Story 2 6 843 19TH ST 4277006021 Soft Story 2 5 847 19TH ST 4277006022 Soft Story 2 5 848 19TH ST 4277008060 Soft Story 3 6 901 19TH ST 4277011013 Soft Story 2 7 13 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 909 19TH ST 4277011077-080 Soft Story 2 4 913 19TH ST 4277011015 Soft Story 3 7 918 19TH ST 4277010005 Soft Story 2 4 922 19TH ST 4277010006 Soft Story 2 6 929 19TH ST 4277011018 Soft Story 2 6 937 19TH ST 4277011050-055 Soft Story 2 6 938 19TH ST 4277010009 Soft Story 2 7 943 19TH ST 4277011021 Soft Story 3 6 944 19TH ST 4277010010 Soft Story 2 6 947 19TH ST 4277011022 Soft Story 2 6 953 19TH ST 4277011023 Soft Story 2 6 1001 19TH ST 4277025065-072 Soft Story 2 8 1020 19TH ST 4277026064-070 Soft Story 3 7 1021 19TH ST 4277025058-063 Soft Story 2 6 1024 19TH ST 4277026007 Soft Story 3 7 1025 19TH ST 4277025003 Soft Story 2 5 1029 19TH ST 4277025004 Soft Story 2 4 1044 19TH ST 4277026071-076 Soft Story 3 6 1047 19TH ST 4277025009 Soft Story 2 8 1048 19TH ST 4277026014 Soft Story 2 4 1107 19TH ST 4276008065-070 Soft Story 2 6 1115 19TH ST 4276008025-035 Soft Story 2 11 1122 19TH ST 4276009014 Soft Story 2 7 1125 19TH ST 4276008005 Soft Story 2 4 1128 19TH ST 4276009015 Soft Story 2 7 1141 19TH ST 4276008008 Soft Story 2 6 1221 19TH ST 4276013026 Soft Story 2 6 1234 19TH ST 4276012044-049 Soft Story 2 6 1253 19TH ST 4276013011 Soft Story 2 4 1307 19TH ST 4276028023 Soft Story 2 7 1308 19TH ST 4276029900 Soft Story 2 0 1312 19TH ST 4276029003 Soft Story 2 6 1318 19TH ST 4276029004 Soft Story 2 6 1324 19TH ST 4276029005 Soft Story 2 6 1328 19TH ST 4276029006 Soft Story 2 5 1329 19TH ST 4276028019 Soft Story 2 4 1343 19TH ST 4276028016 Soft Story 2 6 1423 19TH ST 4275009017 Soft Story 2 6 1428 19TH ST 4275010006 Soft Story 2 5 1433 19TH ST 4275009015 Soft Story 2 4 1439 19TH ST 4275009014 Soft Story 2 4 1441 19TH ST 4275009013 Soft Story 2 4 1528 19TH ST 4275013007 Soft Story 2 6 1533 19TH ST 4275014012 Soft Story 2 5 1824 19TH ST 4274012008 Soft Story 2 8 1833 19TH ST 4274011014 Soft Story 2 5 1837 19TH ST 4274011016 Soft Story 2 7 1838 19TH ST 4274012014 Soft Story 2 7 1842 19TH ST (1844)4274012016 Soft Story 2 5 1904 19TH ST 4274016001 Soft Story 2 4 1908 19TH ST 4274016003 Soft Story 2 6 1912 19TH ST 4274016005 Soft Story 2 3 1918 19TH ST 4274016007 Soft Story 2 4 1944 19TH ST 4274016018 Soft Story 2 4 2009 19TH ST 4274019010 Soft Story 2 7 2023 19TH ST 4274019016 Soft Story 2 5 810 20TH ST 4277006002 Soft Story 3 10 811 20TH ST 4277005017 Soft Story 3 7 817 20TH ST 4277005018 Soft Story 3 7 14 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 818 20TH ST 4277006046-050 4277006052 Soft Story 2 6 821 20TH ST 4277005019 Soft Story 2 4 827 20TH ST 4277005020 Soft Story 2 4 840 20TH ST 4277006026-044 Soft Story 3 19 858 20TH ST 4277006011 Soft Story 2 4 907 20TH ST 4277012014 Soft Story 2 6 914 20TH ST 4277011003 Soft Story 2 0 920 20TH ST 4277011004 Soft Story 2 5 924 20TH ST (924-928 20TH ST)4277011064-075 Soft Story 3 12 942 20TH ST 4277011009 Soft Story 2 3 947 20TH ST 4277012022 Soft Story 2 6 948 20TH ST 4277011082-088 Soft Story 2 7 954 20TH ST (954 20TH ST/1923-1931 WASHINGTON AVE)4277011039-048 Soft Story 3 10 1004 20TH ST (1002-1004 20TH ST/1922-1932 WASHINGTON AVE)4277025026-033 Soft Story 3 8 1007 20TH ST 4277024061-070 Soft Story 2 10 1018 20TH ST (1018-1022 20TH ST)4277025022 Soft Story 2 13 1030 20TH ST 4277025017 Soft Story 2 9 1034 20TH ST 4277025016 Soft Story 2 7 1045 20TH ST 4277024009 Soft Story 2 6 1060 20TH ST 4277025023 Soft Story 2 19 1102 20TH ST 4276008022 Soft Story 2 8 1110 20TH ST 4267008021 Soft Story 2 6 1119 20TH ST 4276007075 Soft Story 2 5 1120 20TH ST 4276008019 Soft Story 2 12 1128 20TH ST 4276008018 Soft Story 2 10 1130 20TH ST 4276008017 Soft Story 2 9 1217 20TH ST 4276014029-040 Soft Story 2 12 1239 20TH ST (1239-1243 20TH ST)4276014041 Soft Story 2 23 1301 20TH ST 4276027017 Steel Moment Frame 6 0 1339 20TH ST 4276027018 Non-Ductile Concrete 2 0 1674 20TH ST 4275025008 Unreinforced Masonry 1 0 1824 20TH ST 4274011032-038 Soft Story 2 7 1837 20TH ST 4274010013 Soft Story 2 2 1932 20TH ST (1932-1934 20TH ST)4274019038 Soft Story 2 3 1943 20TH ST 4274020003 Soft Story 2 12 1948 20TH ST 4274019044 Soft Story 2 7 2016 20TH ST 4274019011 Soft Story 2 3 2017 20TH ST 4274026008 Soft Story 2 6 2023 20TH ST 4274026010 Soft Story 2 6 2115 20TH ST 4273003007 Soft Story 2 4 2116 20TH ST 4273002003 Soft Story 2 6 2121 20TH ST 4273003008 Soft Story 2 4 2134 20TH ST 4273002006 Soft Story 2 7 2137 20TH ST 4273003011 Soft Story 2 6 2140 20TH ST 4273002007 Soft Story 2 3 2201 20TH ST 4273003012 Soft Story 2 4 2215 20TH ST 4273003015 Soft Story 2 5 2221 20TH ST 4273003016 Soft Story 2 6 2225 20TH ST 4273003047-052 Soft Story 2 6 2228 20TH ST 4273002012 Soft Story 2 6 2231 20TH ST 4273003068-073 Soft Story 2 6 2242 20TH ST 4273002015 Soft Story 2 6 2247 20TH ST 4273003055-060 Soft Story 3 6 2249 20TH ST 4273003061-066 Soft Story 3 6 2328 20TH ST 4273021013 Soft Story 2 5 2331 20TH ST 4273018008 Soft Story 2 6 2332 20TH ST 4273021014 Soft Story 2 6 2336 20TH ST 4273021015 Soft Story 2 7 2401 20TH ST 4273018012 Soft Story 2 5 15 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 2407 20TH ST (2405-2409 20TH ST)4273018013 Soft Story 2 4 2411 20TH ST 4273018014 Soft Story 2 6 2419 20TH ST 4273018015 Soft Story 2 0 2420 20TH ST 4273021022 Soft Story 2 5 2430 20TH ST 4273020013 Soft Story 2 5 2431 20TH ST 4273019002 Soft Story 2 4 2441 20TH ST 4273019004 Soft Story 2 5 2446 20TH ST 4273020025-030 Soft Story 2 6 2450 20TH ST 4273020017 Soft Story 2 6 2451 20TH ST 4273019006 Soft Story 2 6 2506 20TH ST 4273020019 Soft Story 2 2 2513 20TH ST 4273019009 Soft Story 2 5 2517 20TH ST 4273019010 Soft Story 2 5 755 21ST ST (2107 MONTANA AVE/755 21ST ST)4278030020 Soft Story 2 7 812 21ST ST 4277005004 Soft Story 2 10 822 21ST ST 4277005006 Soft Story 2 4 828 21ST ST 4277005031-037 Soft Story 2 7 832 21ST ST 4277005008 Soft Story 2 5 839 21ST ST (837)4277004017 Soft Story 2 5 840 21ST ST 4277005009 Soft Story 2 4 843 21ST ST 4277004045-050 Soft Story 2 6 844 21ST ST 4277005010 Soft Story 2 6 847 21ST ST 4277004019 Soft Story 2 4 852 21ST ST 4277005038-043 Soft Story 2 6 921 21ST ST 4277013017 Soft Story 2 6 924 21ST ST 4277012005 Soft Story 2 6 927 21ST ST 4277013054-060 Soft Story 2 7 928 21ST ST 4277012006 Soft Story 2 6 933 21ST ST 4277013040-052 Soft Story 3 13 948 21ST ST 4277012010 Soft Story 2 6 954 21ST ST 4277012011 Soft Story 2 5 1010 21ST ST 4277024022 Soft Story 2 5 1018 21ST ST 4277024017 Soft Story 2 5 1020 21ST ST 4277024018 Soft Story 2 5 1022 21ST ST 4277024019 Soft Story 2 5 1023 21ST ST 4277023008 Soft Story 2 4 1047 21ST ST 4277023019 Soft Story 2 4 1049 21ST ST 4277023020 Soft Story 2 4 1107 21ST ST 4276006005 Soft Story 2 4 1128 21ST ST 4276007007 Soft Story 2 3 1224 21ST ST 4276014005 Soft Story 2 4 1241 21ST ST 4276015006 Soft Story 2 6 1244 21ST ST 4276014009 Soft Story 2 5 1441 21ST ST 4275007010 Non-Ductile Concrete 9 100 1847 21ST ST (2109 DELAWARE AVE)4274009020 Soft Story 2 5 2024 21ST ST 4274026009 Soft Story 2 6 2522 21ST ST 4273019026 Soft Story 2 4 753 22ND ST (753 22ND ST/2221 MONTANA AVE)4278020011 Soft Story 2 3 1102 22ND ST (1102 22ND ST/2120 CALIFORNIA AVE)4276006001 Soft Story 2 5 1115 22ND ST 4276005020 Soft Story 2 5 1130 22ND ST 4276006010 Soft Story 2 3 1133 22ND ST 4276005035 Soft Story 3 10 1143 22ND ST 4276005026 Soft Story 2 5 1223 22ND ST 4276016026 Soft Story 2 2 1228 22ND ST 4276015021 Soft Story 2 3 1237 22ND ST 4276016037-040 Soft Story 2 4 1242 22ND ST 4276015013 Soft Story 2 4 1700 22ND ST (1704)4275030010 Concrete Tilt-Up 1 0 1721 22ND ST 4275032805 Concrete Tilt-Up 2 0 1730 22ND ST (1728)4275031018 Concrete Tilt-Up 1 0 16 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1909 22ND ST 4274022003 Soft Story 2 4 1939 22ND ST 4274022010 Soft Story 2 6 1951 22ND ST 4274022012 Soft Story 2 6 805 23RD ST 4277002011 Soft Story 2 14 840 23RD ST 4277003007 Soft Story 2 1 1120 23RD ST 4276005037-041 Soft Story 2 5 1123 23RD ST 4276004025 Soft Story 2 4 1126 23RD ST 4276005034 Soft Story 2 5 1128 23RD ST 4276005033 Soft Story 2 5 1129 23RD ST 4276004026 Soft Story 2 5 1131 23RD ST 4276004027 Soft Story 2 5 1134 23RD ST 4276005010 Soft Story 3 5 1137 23RD ST 4276004028 Soft Story 2 4 1139 23RD ST 4276004029 Soft Story 2 5 1140 23RD ST 4276005008 Soft Story 2 4 1142 23RD ST 4276005007 Soft Story 2 5 1223 23RD ST 4276017029 Soft Story 2 4 1248 23RD ST 4276016033-036 Soft Story 2 4 1249 23RD ST 4276017022 Soft Story 2 4 1252 23RD ST 4276016013 Soft Story 2 4 1303 23RD ST (2304-2308 ARIZONA AVE)4276024023-026 Soft Story 2 4 1319 23RD ST 4276024016 Soft Story 2 2 1323 23RD ST 4276024015 Soft Story 2 3 1335 23RD ST 4276024012 Soft Story 2 3 2636 23RD ST 4272008024 Soft Story 2 8 2648 23RD ST 4272008018 Soft Story 2 8 1018 24TH ST 4277021013 Soft Story 2 1 1117 24TH ST 4276003019 Soft Story 2 5 1147 24TH ST 4276003057-061 Soft Story 2 5 1220 24TH ST 4276017007 Soft Story 2 4 1224 24TH ST 4276017008 Soft Story 2 3 1227 24TH ST 4276017082-085 Soft Story 2 4 1228 24TH ST 4276017009 Soft Story 2 4 1230 24TH ST 4276017010 Soft Story 2 4 1231 24TH ST 4276017086-089 Soft Story 2 4 1235 24TH ST 4276017102-105 Soft Story 2 4 1455 24TH ST 4275003013 Soft Story 3 16 2210 24TH ST 4273007002 Soft Story 2 4 921 25TH ST 4277017018 Soft Story 2 1 959 25TH ST 4277017025 Soft Story 2 1 1115 25TH ST 4276001007 Soft Story 2 5 1221 25TH ST 4276020026 Soft Story 2 3 1225 25TH ST 4276020025 Soft Story 2 4 1243 25TH ST 4276020021 Soft Story 2 4 1250 25TH ST 4276019016 Soft Story 2 3 1256 25TH ST (1254-1256 25TH ST)4276019017 Soft Story 2 3 1428 25TH ST 4275002006 Soft Story 2 7 1434 25TH ST 4275002007 Soft Story 2 6 1118 26TH ST 4276001008 Soft Story 2 3 1222 26TH ST 4276020007 Soft Story 2 4 1231 26TH ST 4267007026 Soft Story 2 5 1234 26TH ST 4276020010 Soft Story 2 4 1242 26TH ST 4276020012 Soft Story 2 8 1243 26TH ST 4267007023 Soft Story 2 4 1252 26TH ST 4276020013 Soft Story 2 4 1254 26TH ST 4276020014 Soft Story 2 2 1255 26TH ST 4267007020 Soft Story 2 3 1333 26TH ST 4267008012 Soft Story 2 3 1335 26TH ST 4267008011 Soft Story 2 5 1425 26TH ST 4267021009 Soft Story 2 2 17 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1432 26TH ST 4275001006 Soft Story 2 3 1445 26TH ST 4267021012 Soft Story 2 7 1620 26TH ST 4268018046 Steel Moment Frame 6 0 1655 26TH ST 4268001033 Non-Ductile Concrete 2 0 1681 26TH ST 4268001040 Concrete Tilt-Up 2 0 2006 27TH ST 4274004056 Soft Story 3 24 2251 28TH ST 4270004004 Soft Story 2 4 2305 28TH ST (2305-2315 28TH ST)4270004045 Soft Story 3 22 2306 28TH ST 4270003009 Soft Story 2 7 2312 28TH ST 4270003007 Soft Story 2 4 2344 28TH ST 4270003003 Soft Story 2 4 2401 28TH ST 4270004063 Soft Story 2 4 2428 28TH ST 4270014061-072 Soft Story 2 12 2502 28TH ST 4270014057 Soft Story 2 5 2507 28TH ST 4270015130-034 Soft Story 3 4 2525 28TH ST 4270015053 Soft Story 2 5 2604 28TH ST 4270014052 Soft Story 2 7 2607 28TH ST (2607-2609A 28TH ST)4270015056 Soft Story 2 4 2621 28TH ST 4270015060 Soft Story 2 4 2622 28TH ST 4270014050 Soft Story 2 8 2636 28TH ST 4270014049 Soft Story 2 14 2638 28TH ST 4270014048 Soft Story 2 14 2645 28TH ST 4270015063 Soft Story 2 7 2800 28TH ST 4272031005 Steel Moment Frame 3 0 2901 28TH ST 4272029023 Steel Moment Frame 3 0 2268 29TH ST 4270004039 Soft Story 2 4 2250 30TH ST 4270005045 Soft Story 2 3 2254 30TH ST 4270005044 Soft Story 2 6 2653 30TH ST (2653-2655 30TH ST)4270021072 Soft Story 2 7 2305 31ST ST 4270007005 Soft Story 2 5 2666 31ST ST 4270021065 4270021073-081 Soft Story 3 10 2950 31ST ST 4272031001 Steel Moment Frame 3 0 2308 32ND ST 4270007043 Soft Story 2 7 2665 32ND ST (2665-2667 32ND ST)4270019051 Soft Story 2 6 2329 33RD ST (2331)4270009006 Soft Story 2 3 2334 34TH ST 4270009036 Soft Story 2 4 2410 34TH ST 4270009031 Soft Story 2 4 2429 34TH ST 4270010008 Soft Story 2 4 130 ALTA AVE 4293015004 Soft Story 2 9 1661 APPIAN WAY 4290018007 Soft Story 3 6 1665 APPIAN WAY 4290018018 Soft Story 2 4 26 ARCADIA TER 4290018016 Soft Story 3 1 28 ARCADIA TER 4290018015 Soft Story 2 6 36 ARCADIA TER 4290018014 Soft Story 3 12 225 ARIZONA AVE 4291002011 Steel Moment Frame 3 0 301 ARIZONA AVE (301-303)4291003009 Steel Moment Frame 4 0 510 ARIZONA AVE 4291010021 Soft Story 2 9 604 ARIZONA AVE (1301 6TH ST)4291009011 Concrete Tilt-Up 2 0 605 ARIZONA AVE 4291006029 Unreinforced Masonry 2 0 725 ARIZONA AVE 4291007008 Steel Moment Frame 4 0 828 ARIZONA AVE 4282010001 Soft Story 2 11 914 ARIZONA AVE 4282011029 Soft Story 3 10 915 ARIZONA AVE 4282008010 Soft Story 2 7 1120 ARIZONA AVE (1120 ARIZONA AVE/1310-1312 12TH ST)4282013023 Soft Story 3 20 1303 ARIZONA AVE (1301-1303 ARIZONA AVE)4282004013 Soft Story 2 3 1306 ARIZONA AVE 4282015025 Soft Story 2 12 1508 ARIZONA AVE 4282017026 Non-Ductile Concrete 3 0 1713 ARIZONA AVE (1707-1713 ARIZONA AVE)4276011010 Soft Story 2 8 1902 ARIZONA AVE 4276028024 Soft Story 2 8 18 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1916 ARIZONA AVE 4276028001 Soft Story 2 9 2219 ARIZONA AVE (2219 ARIZONA AVE/1260 23RD ST)4276016015 Soft Story 2 4 2441 ARIZONA AVE 4276019019 Soft Story 2 3 2448 ARIZONA AVE 4276022027 Soft Story 2 4 2519 ARIZONA AVE (2519 ARIZONA AVE/1260 26TH ST)4276020015 Soft Story 2 3 2618 ARIZONA AVE 4267008020 Soft Story 2 4 2705 ARIZONA AVE (2705 ARIZONA AVE/1263 PRINCETON ST)4267006003 Soft Story 3 5 2711 ARIZONA AVE 4267006004 Soft Story 3 1 2728 ARIZONA AVE 4267009006 Soft Story 2 6 2803 ARIZONA AVE 4267005016 Soft Story 2 13 2816 ARIZONA AVE 4267010026 Soft Story 2 6 2921 ARIZONA AVE 4267004023 Soft Story 2 10 2927 ARIZONA AVE 4267004002 Soft Story 2 5 3003 ARIZONA AVE (3003-3009 ARIZONA AVE)4267003021 Soft Story 2 18 3015 ARIZONA AVE 4267003020 Soft Story 2 5 3101 ARIZONA AVE 4267002023 Soft Story 2 6 301 ASHLAND AVE 4287022017 Soft Story 3 9 508 ASHLAND AVE 4287026045 Soft Story 3 16 523 ASHLAND AVE 4287020025 Soft Story 3 7 602 ASHLAND AVE 4287026042 Soft Story 3 12 724 ASHLAND AVE 4287030023 Soft Story 3 4 730 ASHLAND AVE 4287030025 Soft Story 2 4 734 ASHLAND AVE 4287030027 Soft Story 2 4 835 ASHLAND AVE 4285012013 Soft Story 2 9 1000 ASHLAND AVE 4285027001 Soft Story 2 7 1003 ASHLAND AVE (1005)4285012014 Soft Story 2 8 1015 ASHLAND AVE 4285012016 Soft Story 2 7 1023 ASHLAND AVE 4285012018 Soft Story 2 6 2450 ASHLAND AVE 4272031908 Soft Story 1 0 3355 BARNARD WAY 4288027024 Non-Ductile Concrete 4 0 225 BAY ST 4289019009 Soft Story 2 7 230 BAY ST 4289018007 Soft Story 2 12 236 BAY ST 4289018006 Soft Story 2 12 300 BAY ST 4289013025 Soft Story 3 26 325 BAY ST 4289012016 Soft Story 2 48 419 BAY ST 4289011025 Soft Story 2 4 443 BAY ST 4289011027 Soft Story 2 6 511 BAY ST 4289011031 Soft Story 2 2 609 BAY ST (609 BAY ST/1933 6TH ST)4289003016 Soft Story 2 4 820 BAY ST 4284002007 Soft Story 3 5 827 BAY ST 4284001042-050 Soft Story 2 9 1009 BAY ST 4284016019 Soft Story 2 4 1035 BAY ST (1033-1035 BAY ST)4284016014 Soft Story 2 4 1114 BAY ST 4284018010 Soft Story 2 3 1118 BAY ST 4284018009 Soft Story 2 3 1204 BAY ST 4284018005 Soft Story 2 5 1209 BAY ST 4284017001 Soft Story 2 4 1047 BERKELEY ST 4266006046 Soft Story 2 1 1223 BERKELEY ST 4267002016 Soft Story 2 6 1228 BERKELEY ST 4267003005 Soft Story 2 9 1233 BERKELEY ST 4267002028-034 Soft Story 2 7 1237 BERKELEY ST 4267002019 Soft Story 2 6 1247 BERKELEY ST 4267002021 Soft Story 2 6 1253 BERKELEY ST 4267002035-041 Soft Story 2 7 1307 BERKELEY ST 4267013023 Soft Story 2 4 1323 BERKELEY ST 4267013016 Soft Story 2 4 1324 BERKELEY ST 4267012017 Soft Story 2 7 1327 BERKELEY ST 4267013014 Soft Story 2 6 1328 BERKELEY ST 4267012049-055 Soft Story 3 7 19 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1341 BERKELEY ST 4267013008 Soft Story 2 7 1419 BERKELEY ST 4267016008 Soft Story 2 2 1437 BERKELEY ST 4267016030-035 Soft Story 2 6 1448 BERKELEY ST 4267017021 Soft Story 2 7 1453 BERKELEY ST 4267016023 Soft Story 2 7 1458 BERKELEY ST 4267017025 Soft Story 2 6 1507 BERKELEY ST 4267027003 Soft Story 2 7 1518 BERKELEY ST 4267026008 Soft Story 2 7 1528 BERKELEY ST 4267026068-074 Soft Story 2 7 1532 BERKELEY ST 4267026061-067 Soft Story 2 7 1533 BERKELEY ST 4267027014 Soft Story 2 7 1537 BERKELEY ST 4267027016 Soft Story 3 7 1633 BERKELEY ST 4268005024 Soft Story 2 4 1634 BERKELEY ST 4268004012 Soft Story 2 3 1637 BERKELEY ST 4268005023 Soft Story 2 4 1642 BERKELEY ST 4268004014 Soft Story 3 4 1649 BERKELEY ST 4268005020 Soft Story 2 3 1653 BERKELEY ST 4268005019 Soft Story 2 4 1660 BERKELEY ST 4268004018 Soft Story 2 6 2428 BEVERLEY AVE 4287005012 Soft Story 2 4 2441 BEVERLEY AVE 4287004022 Soft Story 3 19 2450 BEVERLEY AVE 4287005017 Soft Story 2 6 2525 BEVERLEY AVE 4287003008 Soft Story 3 10 2534 BEVERLEY AVE 4287005007 Soft Story 2 4 2545 BEVERLEY AVE (2535-2545 BEVERLEY AVE)4287003009 Soft Story 2 26 208 BICKNELL AVE 4289017003 Unreinforced Masonry 1 2 217 BICKNELL AVE 4289018013 Soft Story 2 6 225 BICKNELL AVE (223-225 BICKNELL AVE)4289018012 Soft Story 2 7 229 BICKNELL AVE 4289018027-053 Soft Story 4 27 236 BICKNELL AVE 4289017009 Soft Story 2 12 246 BICKNELL AVE 4289017019 Soft Story 2 7 323 BICKNELL AVE 4289013026 Soft Story 3 11 101 BROADWAY 4291015017 Unreinforced Masonry 3 0 127 BROADWAY (119 BROADWAY)4291015027 Unreinforced Masonry 2 0 201 BROADWAY 4291016013 Unreinforced Masonry 4 0 227 BROADWAY 4291016012 Unreinforced Masonry 3 0 309 BROADWAY 4291017025 Steel Moment Frame 5 0 420 BROADWAY 4291025033 Unreinforced Masonry 1 0 520 BROADWAY 4291019028 Steel Moment Frame 6 0 719 BROADWAY 4291021015 Unreinforced Masonry 1 0 804 BROADWAY (802)4282028017 Unreinforced Masonry 1 0 1721 BROADWAY (1721-31)4275011027 Unreinforced Masonry 1 0 1827 BROADWAY (1819) 4275010012 Unreinforced Masonry 1 0 2001 BROADWAY 4275008808 Concrete Tilt-Up 3 0 2500 BROADWAY 4275017014 Steel Moment Frame 5 0 2601 BROADWAY (2601-2609 BROADWAY)4267021015 Soft Story 2 5 2702 BROADWAY 4267023025 Soft Story 2 4 2719 BROADWAY (2719-2727 BROADWAY)4267020014 Soft Story 2 4 2814 BROADWAY (2818)4267024002 Soft Story 2 3 2905 BROADWAY (2911)4267018024 Soft Story 2 5 3201 BROADWAY (3201 BROADWAY/1457 FRANKLIN ST)4267015024 Soft Story 2 2 101 CALIFORNIA AVE 4292027023-113 Steel Moment Frame 13 91 210 CALIFORNIA AVE 4292021020 Soft Story 3 10 220 CALIFORNIA AVE 4292021015 Soft Story 3 36 300 CALIFORNIA AVE 4292020010 Soft Story 3 35 320 CALIFORNIA AVE 4292020009 Soft Story 2 1 329 CALIFORNIA AVE 4292019016 Soft Story 3 20 330 CALIFORNIA AVE 4292020001 Unreinforced Masonry 5 w/basement and sub- parking 45 414 CALIFORNIA AVE 4292013019 Soft Story 2 7 20 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 420 CALIFORNIA AVE 4292013022 Soft Story 3 20 507 CALIFORNIA AVE 4292011029 Soft Story 3 20 519 CALIFORNIA AVE 4292011066-079 Soft Story 3 14 520 CALIFORNIA AVE 4292012022 Soft Story 3 7 621 CALIFORNIA AVE 4292006054-059 Soft Story 3 6 715 CALIFORNIA 4292003028 Unreinforced Masonry 2 0 819 CALIFORNIA AVE 4281034026 Soft Story 2 12 901 CALIFORNIA AVE (901-909 CALIFORNIA AVE)4281029051-059 Soft Story 2 9 902 CALIFORNIA AVE 4281028023 Soft Story 2 4 911 CALIFORNIA AVE 4281029020 Soft Story 2 4 914 CALIFORNIA AVE 4281028027 Soft Story 3 7 919 CALIFORNIA AVE 4281029023 Soft Story 2 6 1015 CALIFORNIA AVE 4281026021 Non-Ductile Concrete 2 0 1107 CALIFORNIA AVE 4281021013 Soft Story 2 4 1121 CALIFORNIA AVE 4281021026 Soft Story 3 7 1204 CALIFORNIA AVE 4281019019 Soft Story 2 7 1208 CALIFORNIA AVE 4281019020 Soft Story 3 4 1219 CALIFORNIA AVE 4281018025 Soft Story 2 4 1220 CALIFORNIA AVE 4281019025 Soft Story 2 14 1311 CALIFORNIA AVE 4281013025 Soft Story 3 7 1321 CALIFORNIA AVE 4281013024 Soft Story 3 5 1422 CALIFORNIA AVE 4281011043-047 Soft Story 3 5 1601 CALIFORNIA AVE 4281003023 Soft Story 2 7 1610 CALIFORNIA AVE 4281004023 Soft Story 2 4 1614 CALIFORNIA AVE (1612-1614 CALIFORNIA AVE)4281004025 Soft Story 3 2 1701 CALIFORNIA AVE (1701-1707 CALIFORNIA AVE)4277027023 Soft Story 2 2 1710 CALIFORNIA AVE 4276010011 Soft Story 2 6 1730 CALIFORNIA AVE 4276010041-047 Soft Story 3 7 1811 CALIFORNIA AVE 4277026023 Soft Story 2 1 1903 CALIFORNIA AVE 4277025011 Soft Story 2 4 2021 CALIFORNIA AVE 4277024026-048 Soft Story 3 23 2101 CALIFORNIA AVE 4277023021 Soft Story 3 9 711 CEDAR ST 4287001016 Soft Story 2 4 717 CEDAR ST (717-723 CEDAR ST)4287001033-042 Soft Story 2 10 722 CEDAR ST 4287001020 Soft Story 2 6 734 CEDAR ST 4287001019 Soft Story 2 10 835 CEDAR ST 4284005002 Soft Story 2 4 1031 CEDAR ST 4284012005 Soft Story 2 1 1321 CENTINELA AVE 4267014025 Soft Story 2 9 1333 CENTINELA AVE 4267014023 Soft Story 2 7 1341 CENTINELA AVE 4267014035-041 Soft Story 3 7 1415 CENTINELA AVE 4267015009 Soft Story 2 5 1453 CENTINELA AVE 4267015023 Soft Story 2 4 1521 CENTINELA AVE 4267028004 Soft Story 2 5 1537 CENTINELA AVE 4267028007 Soft Story 2 7 1615 CENTINELA AVE 4268006008 Soft Story 2 4 1625 CENTINELA AVE (1621)4268006057-0066 Soft Story 2 10 1645 CENTINELA AVE 4268006015 Soft Story 2 6 1715 CENTINELA AVE 4268007004 Soft Story 2 5 1723 CENTINELA AVE 4268007033 Soft Story 2 5 1725 CENTINELA AVE 4268007007 Soft Story 2 5 1733 CENTINELA AVE 4268007035 Soft Story 2 10 1741 CENTINELA AVE 4268007010 Soft Story 2 5 1743 CENTINELA AVE 4268007011 Soft Story 2 5 1759 CENTINELA AVE (1759 CENTINELA AVE/3221 NEBRASKA AVE)4268007015 Soft Story 2 4 2621 CENTINELA AVE 4270017120-141 Soft Story 3 22 2633 CENTINELA AVE 4270017108-119 Soft Story 3 12 2637 CENTINELA AVE 4270017030 Soft Story 2 30 2643 CENTINELA AVE 4270017028 Soft Story 3 48 21 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1116 CHELSEA AVE 4276003011 Soft Story 2 5 1120 CHELSEA AVE 4276003010 Soft Story 2 5 1124 CHELSEA AVE 4276003009 Soft Story 2 4 1134 CHELSEA AVE (1130-1134 CHELSEA AVE)4276003008 Soft Story 2 8 1226 CHELSEA AVE 4276017050 Soft Story 2 4 1251 CHELSEA AVE 4276019020 Soft Story 2 4 2439 CHELSEA PL 4276022018 Soft Story 2 4 2440 CHELSEA PL 4276022012 Soft Story 2 4 2445 CHELSEA PL 4276022019 Soft Story 2 1 2447 CHELSEA PL 4276022020 Soft Story 2 4 2453 CHELSEA PL 4276022051 Soft Story 2 4 1411 CLOVERFIELD BLVD 4275004015 Soft Story 2 2 1413 CLOVERFIELD BLVD 4275004016 Soft Story 2 0 1419 CLOVERFIELD BLVD 4275004017 Soft Story 2 2 1423 CLOVERFIELD BLVD 4275004018 Soft Story 2 3 1644 CLOVERFIELD BLVD 4275020033 Non-Ductile Concrete 7 0 1707 CLOVERFIELD BLVD 4268014013 Concrete Tilt-Up 2 0 1919 CLOVERFIELD BLVD 4274001034 Soft Story 2 7 1925 CLOVERFIELD BLVD 4274001036 Soft Story 2 7 2014 CLOVERFIELD BLVD 4274024013 Soft Story 3 11 2029 CLOVERFIELD BLVD (2023-2033 CLOVERFIELD BLVD)4274005035-056 Soft Story 2 22 2041 CLOVERFIELD BLVD 4274005022 Soft Story 2 7 2206 CLOVERFIELD BLVD 4273006029 Soft Story 2 4 2207 CLOVERFIELD BLVD 4273007024 Soft Story 2 3 2621 CLOVERFIELD BLVD (2621-2627 CLOVERFIELD BLVD)4273011020 Soft Story 2 4 2626 CLOVERFIELD BLVD 4273012016 Soft Story 2 10 120 COLORADO AVE 4290015026 Non-Ductile Concrete 9 0 302 COLORADO AVE 4290012003 Non-Ductile Concrete 3 0 407 COLORADO AVE 4291025012 Steel Moment Frame 1 0 700 COLORADO AVE (702)4290001016 Concrete Tilt-Up 1 0 716 COLORADO AVE 4290001016 Unreinforced Masonry 2 0 902-926 COLORADO AVE 4283002900 Concrete Tilt-Up 1 0 1101 COLORADO AVE 4282031016 Concrete Tilt-Up 2 0 1431 COLORADO AVE 4282034009 Concrete Tilt-Up 1 0 1920 COLORADO AVE 4275021007 Concrete Tilt-Up 2 0 2100 COLORADO AVE 4275020015 Steel Moment Frame 3 0 2150 COLORADO AVE 4275020025 Steel Moment Frame 4 0 2600 COLORADO AVE 4268001050 Non-Ductile Concrete 5 0 2815 COLORADO AVE 4267024032 Soft Story 2 3 2821 COLORADO AVE 4267024027 Soft Story 2 6 2917 COLORADO AVE 4267025023 Soft Story 2 5 2929 COLORADO AVE 4267025028 Soft Story 2 18 3010 COLORADO AVE 4268004003 Soft Story 2 4 3014 COLORADO AVE 4268004004 Soft Story 2 5 3022 COLORADO AVE 4268004006 Soft Story 2 4 3116 COLORADO AVE 4268005004 Soft Story 2 4 3120 COLORADO AVE 4268005005 Soft Story 2 4 3124 COLORADO AVE 4268005006 Soft Story 2 4 3219 COLORADO AVE 4267028026-036 Soft Story 2 11 654 COPELAND CT 4287015010 Soft Story 3 1 1723 DELAWARE AVE (1723-1727 DELAWARE AVE)4274013019 Soft Story 2 5 1802 DELAWARE AVE 4274016002 Soft Story 2 5 2801 DELAWARE AVE 4268019041 Soft Story 2 3 2951 DONALD DOUGLAS LOOP N 4272031002 Steel Moment Frame 3 0 3223 DONALD DOUGLAS LOOP S 4272026902 Steel Moment Frame 2 0 811 EUCLID ST 4281015021 Soft Story 3 10 817 EUCLID ST 4281015020 Soft Story 2 8 818 EUCLID ST 4281016003 Soft Story 2 5 825 EUCLID ST 4281015019 Soft Story 3 11 829 EUCLID ST 4281015018 Soft Story 3 10 22 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 832 EUCLID ST 4281016033-053 Soft Story 3 21 833 EUCLID ST (831-833 EUCLID ST)4281015017 Soft Story 2 5 837 EUCLID ST 4281015016 Soft Story 2 6 842 EUCLID ST 4281016006 Soft Story 2 5 901 EUCLID ST 4281014024 Soft Story 2 6 909 EUCLID ST 4281014023 Soft Story 2 6 943 EUCLID ST 4281014014 Soft Story 2 8 948 EUCLID ST (948-950 EUCLID ST)4281017010 Soft Story 2 5 949 EUCLID ST 4281014013 Soft Story 3 16 952 EUCLID ST (952-956 EUCLID ST)4281017011 Soft Story 2 8 1018 EUCLID ST 4281018005 Soft Story 3 11 1027 EUCLID ST 4281013018 Soft Story 2 6 1033 EUCLID ST 4281013017 Soft Story 3 8 1034 EUCLID ST 4281018008 Soft Story 2 3 1040 EUCLID ST 4281018009 Soft Story 3 11 1041 EUCLID ST 4281013015 Soft Story 2 10 1044 EUCLID ST 4281018010 Soft Story 3 11 1050 EUCLID ST 4281018011 Soft Story 4 11 1101 EUCLID ST 4281012015 Soft Story 2 5 1102 EUCLID ST 4281019001 Soft Story 3 7 1111 EUCLID ST 4281012036-046 Soft Story 4 11 1114 EUCLID ST 4281019003 Soft Story 3 21 1115 EUCLID ST (1115-1117 EUCLID ST)4281012013 Soft Story 2 8 1122 EUCLID ST 4281019005 Soft Story 2 4 1128 EUCLID ST 4281019006 Soft Story 2 7 1138 EUCLID ST 4281019008 Soft Story 3 11 1227 EUCLID ST 4282004019 Soft Story 3 10 1228 EUCLID ST 4282005005 Soft Story 3 10 1236 EUCLID ST 4282005007 Soft Story 3 10 1244 EUCLID ST 4282005008 Soft Story 3 12 1246 EUCLID ST 4282005009 Soft Story 3 11 1251 EUCLID ST 4282004014 Soft Story 3 7 1302 EUCLID ST 4282014028 Soft Story 3 18 1307 EUCLID ST 4282015024 Soft Story 3 10 1311 EUCLID ST 4282015023 Soft Story 3 11 1314 EUCLID ST (1304-1314 EUCLID ST)4282014003 Soft Story 3 11 1318 EUCLID ST 4282014004 Soft Story 3 11 1321 EUCLID ST 4282015021 Soft Story 3 11 1322 EUCLID ST 4282014005 Soft Story 2 11 1328 EUCLID ST 4282014006 Soft Story 2 11 1334 EUCLID ST 4282014007 Soft Story 2 10 1423 EUCLID ST 4282022021 Soft Story 3 11 1433 EUCLID ST 4282022019 Soft Story 2 11 1437 EUCLID ST 4282022018 Soft Story 2 11 1518 EUCLID ST (1518-1522 EUCLID ST)4282032031 Soft Story 3 20 1525 EUCLID ST 4282033900 Unreinforced Masonry 2 0 1534 EUCLID ST 4282032007 Soft Story 2 10 1538 EUCLID ST 4282032008 Soft Story 2 11 1543 EUCLID ST 4282033015 Soft Story 2 10 1550 EUCLID ST 4282032010 Unreinforced Masonry 1 0 1754 EUCLID ST 4283015002 Soft Story 2 6 1817 EUCLID ST 4283029003 Soft Story 2 5 1827 EUCLID ST 4283029006 Soft Story 2 6 1840 EUCLID ST 4283028014 Soft Story 2 5 1844 EUCLID ST 4283028013 Soft Story 2 4 1851 EUCLID ST (1847-1853 EUCLID ST)4283029026 Soft Story 2 7 1911 EUCLID ST 4283029013 Soft Story 2 6 1934 EUCLID ST 4283028004 Soft Story 2 6 1938 EUCLID ST 4283028003 Soft Story 2 8 1942 EUCLID ST 4283028002 Soft Story 3 15 23 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 2019 EUCLID ST 4284033006 Soft Story 2 5 2521 EUCLID ST (2521 EUCLID ST/1307 OCEAN PARK BLVD)4284025001 Soft Story 2 7 2612 EUCLID ST 4285002001 Soft Story 2 7 2711 EUCLID ST 4285010008 Soft Story 2 3 2860 EXPOSITION BLVD 4268019029 Soft Story 2 4 2900 EXPOSITION BLVD 4268022001 Soft Story 2 3 2918 EXPOSITION BLVD (2918-2920 EXPOSITION BLVD)4268022004 Soft Story 2 3 2958 EXPOSITION BLVD 4268022012 Soft Story 2 3 1957 FRANK ST (1951-1957 FRANK ST/2519 VIRGINIA AVE)4274003032 Soft Story 3 20 1249 FRANKLIN ST 4267001010 Soft Story 2 8 1301 FRANKLIN ST (1301-1317 FRANKLIN ST)4267014057-080 Soft Story 2 24 1302 FRANKLIN ST 4267013022 Soft Story 3 33 1328 FRANKLIN ST 4267013042-048 Soft Story 2 7 1332 FRANKLIN ST 4267013013 Soft Story 2 6 1335 FRANKLIN ST 4267014032 Soft Story 2 11 1419 FRANKLIN ST 4267015008 Soft Story 2 3 1434 FRANKLIN ST 4267016016 Soft Story 2 4 1447 FRANKLIN ST 4267015037-042 Soft Story 2 6 1510 FRANKLIN ST 4267027057 Soft Story 2 3 1601 FRANKLIN ST 4268006001 Soft Story 2 5 1621 FRANKLIN ST 4268006067 Soft Story 2 4 1622 FRANKLIN ST 4268005008 Soft Story 2 2 1629 FRANKLIN ST 4268006033-037 Soft Story 2 5 1646 FRANKLIN ST 4268005014 Soft Story 2 4 1653 FRANKLIN ST 4268006020 Soft Story 2 4 1712 FRANKLIN ST (1710-1712 FRANKLIN ST)4268008003 Soft Story 2 4 1716 FRANKLIN ST 4268008004 Soft Story 2 1 1735 FRANKLIN ST 4268007022 Soft Story 2 5 1736 FRANKLIN ST 4268008009 Soft Story 2 3 1744 FRANKLIN ST 4268008011 Soft Story 2 3 1748 FRANKLIN ST 4268008012 Soft Story 2 4 1755 FRANKLIN ST 4268007034 Soft Story 2 10 123 FRASER AVE 4288018032 Soft Story 2 5 701 GRANT ST 4289002029-040 Soft Story 2 12 707 GRANT ST 4289002041-046 Soft Story 2 6 825 GRANT ST (825-829 GRANT ST)4284002019 Soft Story 2 10 909 GRANT ST 4284002042-046 Soft Story 2 5 1007 GRANT ST 4284015020 Soft Story 2 4 1011 GRANT ST 4284015019 Soft Story 2 4 1018 GRANT ST 4284014003 Soft Story 2 5 1022 GRANT ST 4284014004 Soft Story 2 5 1038 GRANT ST (1038-1040 GRANT ST)4284014007 Soft Story 3 3 1043 GRANT ST 4284015013 Soft Story 2 4 1044 GRANT ST 4284014009 Soft Story 2 3 121 HART AVE 4288017030 Soft Story 3 1 156 HART AVE 4288018042-045 Soft Story 4 4 1143 HARVARD ST 4266009059 Soft Story 2 6 1240 HARVARD ST 4267006018 Soft Story 2 6 1242 HARVARD ST 4267006019 Soft Story 2 8 1321 HARVARD ST 4267010019 Soft Story 2 6 1323 HARVARD ST 4267010017 Soft Story 2 6 1338 HARVARD ST 4267009036-039 Soft Story 2 4 1342 HARVARD ST 4267009056 Soft Story 3 10 1452 HARVARD ST 4267020013 Soft Story 2 5 1505 HARVARD ST (1505-1507 HARVARD ST)4267024005 Soft Story 2 8 1508 HARVARD ST 4267023045-046 Soft Story 2 2 1517 HARVARD ST 4267024051-059 Soft Story 2 9 1518 HARVARD ST 4267023005 Soft Story 2 6 1522 HARVARD ST 4267023006 Soft Story 2 6 1527 HARVARD ST 4267024013 Soft Story 2 8 24 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1530 HARVARD ST 4267023007 Soft Story 2 5 1536 HARVARD ST 4267023008 Soft Story 2 6 1548 HARVARD ST 4267023011 Soft Story 2 4 2627 HIGHLAND AVE 4287015037 Soft Story 3 10 2660 HIGHLAND AVE 4287019026 Soft Story 3 6 3001 HIGHLAND AVE 4287029002 Soft Story 3 3 3110 HIGHLAND AVE 4287037029 Soft Story 3 3 240 HILL ST (240 HILL ST/2704 3RD ST)4287023001 Soft Story 3 4 420 HILL ST 4287021009 Soft Story 2 7 422 HILL ST 4287021010 Soft Story 2 11 423 HILL ST 4287012003 Soft Story 3 6 428 HILL ST 4287021042-063 Soft Story 3 22 500 HILL ST 4287021013 Soft Story 2 9 507 HILL ST 4287013007 Soft Story 2 5 508 HILL ST 4287021015 Soft Story 2 6 511 HILL ST 4287013031 Soft Story 3 13 519 HILL ST (519-523 HILL ST)4287013030 Soft Story 3 15 639 HILL ST 4287015030 Soft Story 2 6 643 HILL ST 4287015031 Soft Story 2 6 647 HILL ST 4287015032 Soft Story 2 5 648 HILL ST 4287018025 Soft Story 2 4 701 HILL ST 4287016034 Soft Story 2 4 711 HILL ST 4287016036 Soft Story 2 4 721 HILL ST 4287016044 Soft Story 2 11 733 HILL ST 4287016040 Soft Story 2 5 817 HILL ST 4285001033 Soft Story 2 14 825 HILL ST 4285001003 Soft Story 2 5 829 HILL ST 4285001004 Soft Story 2 6 1021 HILL ST 4285001050-056 Soft Story 2 7 1028 HILL ST 4285012026 Soft Story 2 4 1518 HILL ST 4285015003 Soft Story 2 1 2019 HILL ST 4272002013 Soft Story 2 1 2437 HILL ST 4272020008 Soft Story 2 2 136 HOLLISTER AVE 4288016040 Soft Story 3 1 423 HOLLISTER AVE (421-423 HOLLISTER AVE/2332 5TH ST)4289007006 Soft Story 2 3 601 HOLLISTER AVE 4289006005 Soft Story 2 5 124 IDAHO AVE 4292026044-064 Non-Ductile Concrete 6 21 325 IDAHO AVE 4292017013 Soft Story 3 12 425 IDAHO AVE 4292016052-061 Soft Story 3 10 505 IDAHO AVE 4292009016 Soft Story 3 21 519 IDAHO AVE 4292009014 Soft Story 3 7 525 IDAHO AVE 4292009013 Soft Story 2 5 608 IDAHO AVE 4292007030-040 Soft Story 3 11 629 IDAHO AVE 4292008032-054 Soft Story 3 23 806 IDAHO AVE (802-812 IDAHO AVE/903 LINCOLN)4281033023 Soft Story 3 6 929 IDAHO AVE 4281031011 Soft Story 3 10 1025 IDAHO AVE 4281024057 Soft Story 3 11 1105 IDAHO AVE 4281023032-041 Soft Story 3 10 1201 IDAHO AVE 4281016009 Soft Story 2 10 1214 IDAHO AVE 4281017023 Soft Story 3 10 1315 IDAHO AVE 4281015025 Soft Story 3 7 1324 IDAHO AVE 4281014001 Soft Story 2 6 1325 IDAHO AVE 4281015012 Soft Story 2 6 1509 IDAHO AVE (1501-1509 IDAHO AVE)4281008013 Soft Story 2 4 1527 IDAHO AVE (1527 IDAHO AVE/858 16TH ST)4281008012 Soft Story 2 3 1606 IDAHO AVE (1604-1606 IDAHO AVE)4281002025 Soft Story 2 6 1720 IDAHO AVE (902 18TH ST)4277009001 Soft Story 2 1 1810 IDAHO AVE (1810-1816)4277010012 Soft Story 2 4 1820 IDAHO AVE 4277010070-076 Soft Story 3 7 1903 IDAHO AVE (1903-1913 IDAHO AVE)4277006024 Soft Story 2 6 25 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 2315 KANSAS AVE 4274005023 Soft Story 2 5 2345 KANSAS AVE 4274005030 Soft Story 2 22 2351 KANSAS AVE 4274005031 Soft Story 2 9 2428 KANSAS AVE 4274007010 Soft Story 2 7 2434 KANSAS AVE 4274007011 Soft Story 2 7 2512 KANSAS AVE 4274007014 Soft Story 2 7 2519 KANSAS AVE 4274004061-070 Soft Story 3 10 2546 KANSAS AVE 4274007018 Soft Story 2 13 2624 KANSAS AVE (2624-2628 KANSAS AVE)4274008046-076 Soft Story 2 31 2625 KANSAS AVE 4274004043 Soft Story 2 16 2633 KANSAS AVE 4274004044 Soft Story 2 11 2801 KANSAS AVE (2801-2809 KANSAS AVE)4274028011 Soft Story 2 5 650 KENSINGTON RD 4287004010 Soft Story 3 4 608 LINCOLN BLVD 4293011034-039 Soft Story 2 6 632 LINCOLN BLVD 4293011052-056 Soft Story 2 5 638 LINCOLN BLVD 4293011008 Soft Story 2 5 702 LINCOLN BLVD 4293011009 Soft Story 2 6 714 LINCOLN BLVD 4293011011 Soft Story 2 5 728 LINCOLN BLVD (728-730 LINCOLN BLVD)4293011047-050 Soft Story 2 4 823 LINCOLN BLVD 4281032019 Soft Story 2 10 824 LINCOLN BLVD 4292001006 Soft Story 2 10 828 LINCOLN BLVD 4292001007 Soft Story 3 11 838 LINCOLN BLVD 4292001009 Soft Story 3 10 841 LINCOLN BLVD 4281032015 Soft Story 2 10 844 LINCOLN BLVD 4292001010 Soft Story 2 10 847 LINCOLN BLVD 4281032014 Soft Story 2 6 858 LINCOLN BLVD (721-727 IDAHO AVE)4292001013 Soft Story 2 14 917 LINCOLN BLVD 4281033020 Soft Story 2 6 927 LINCOLN BLVD (927-929 LINCOLN BLVD)4281033018 Soft Story 2 2 942 LINCOLN BLVD 4292002009 Soft Story 2 3 943 LINCOLN BLVD 4281033056-061 Soft Story 3 6 948 LINCOLN BLVD 4292002010 Soft Story 1 2 1007 LINCOLN BLVD 4281034024 Soft Story 3 11 1041 LINCOLN BLVD 4281034040-046 Soft Story 3 7 1111 LINCOLN BLVD 4281035019 Soft Story 3 10 1123 LINCOLN BLVD 4281035017 Soft Story 3 10 1130 LINCOLN BLVD 4292004900 Unreinforced Masonry 2 0 1143 LINCOLN BLVD 4281035013 Soft Story 3 8 1147 LINCOLN BLVD 4281035026 Soft Story 3 10 1231 LINCOLN BLVD (1233)4282009017 Unreinforced Masonry 2 0 1448 LINCOLN BLVD 4291021011 Unreinforced Masonry 1 0 1452 LINCOLN BLVD 4291021012 Unreinforced Masonry 1 0 1637 LINCOLN BLVD 4283002006 Concrete Tilt-Up 1 0 1661 LINCOLN BLVD 4283003012 Non-Ductile Concrete 4 0 1824 LINCOLN BLVD (1822)4290004023 Unreinforced Masonry 1 0 1836 LINCOLN BLVD 4290004028 Soft Story 2 0 1900 LINCOLN BLVD (1900-1916)4289003045 Unreinforced Masonry 1 0 2316 LINCOLN BLVD 4289001007 Unreinforced Masonry 1 0 2323 LINCOLN BLVD 4284005021 Unreinforced Masonry 1 0 1855 MAIN ST 4290013901 Non-Ductile Concrete 3 0 1901 MAIN ST 4289019024 Steel Moment Frame 3 0 1918 MAIN ST 4289020005 Steel Moment Frame 3 0 1918 MAIN ST 4289020005 Soft Story 3 0 1921 MAIN ST (1921-29)4289019006 Unreinforced Masonry 1 0 2003 MAIN ST (2001-2011)4289018001 Unreinforced Masonry 1 0 2015 MAIN ST 4289018003 Unreinforced Masonry 1 0 2403 MAIN ST 4288001040 Unreinforced Masonry 1 0 2409 MAIN ST 4288001020 Unreinforced Masonry 2 0 2411 MAIN ST 4288001021 Unreinforced Masonry 1 0 2515 MAIN ST 4288001035 Concrete Tilt-Up 2 0 26 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 2525 MAIN ST 4288001036 Unreinforced Masonry 3 0 2601 MAIN ST 4288002902 Unreinforced Masonry 1 0 2633 MAIN ST 4288002027 Unreinforced Masonry 1 0 2654 MAIN ST 4288012001 Unreinforced Masonry 2 0 2701 MAIN ST (2703) (210 HILL ST) 4288003043 Unreinforced Masonry 1 0 2702 MAIN ST 4288011016 Unreinforced Masonry 1 0 2709 MAIN ST 4288003042 Unreinforced Masonry 1 0 2711 MAIN ST 4288003041 Unreinforced Masonry 1 0 2724 MAIN ST 4288011017 Unreinforced Masonry 1 0 2804 MAIN ST (2802-2808)4288010005 Unreinforced Masonry 2 0 2807 MAIN ST 4288003029 Unreinforced Masonry 1 0 2821 MAIN ST (2815-2821)4288003023 Unreinforced Masonry 2 0 2900 MAIN ST 4288009001 Unreinforced Masonry 2 0 2905 MAIN ST (2901)4288004024 Unreinforced Masonry 1 0 2909 MAIN ST (2907-2915)4288004023 Unreinforced Masonry 1 0 2934 MAIN ST (2936)4288008005 Unreinforced Masonry 1 with mezanine 0 2941 MAIN ST 4288004027 Unreinforced Masonry 2 0 2942 MAIN ST (181 PIER AVE) 4288008007 Unreinforced Masonry 2 w/tower 0 3005 MAIN ST 4288005015 Steel Moment Frame 5 0 3015 MAIN ST 4288005015 Steel Moment Frame 4 0 818 MAPLE ST 4284008010 Soft Story 2 3 824 MAPLE ST 4284008011 Soft Story 2 6 1503 MAPLE ST 4284038022 Soft Story 2 2 323 MARINE ST 4287025022 Soft Story 4 24 425 MARINE ST 4287027059-064 Soft Story 4 6 431 MARINE ST 4287027022 Soft Story 2 6 607 MARINE ST 4287027034 Soft Story 3 8 642 MARINE ST 4287035023 Soft Story 2 4 653 MARINE ST (653 MARINE ST/3025 GOLDSMITH ST)4287028008 Soft Story 2 3 668 MARINE ST (666-672)4287035001 Unreinforced Masonry 2 0 728 MARINE ST 4287034033 Soft Story 3 1 730 MARINE ST 4287034032 Soft Story 3 1 929 MARINE ST 4285029015 Soft Story 2 3 820 MICHIGAN AVE 4283020002 Soft Story 2 3 1220 MICHIGAN AVE (1222) (1802 EUCLID ST)4283028021 Soft Story 2 3 1358 MICHIGAN AVE (1804 14TH ST)4283030025 Unreinforced Masonry 2 0 1513 MICHIGAN AVE 4283012022 Soft Story 2 5 1811 MICHIGAN AVE (1801-1823 MICHIGAN AVE)4274027015 Soft Story 2 7 2211 MICHIGAN AVE 4275032009 Concrete Tilt-Up 1 0 135 MONTANA AVE 4293014027 Soft Story 2 18 219 MONTANA AVE 4293014088-103 Soft Story 3 16 311 MONTANA AVE 4293014019 Soft Story 3 16 402 MONTANA AVE 4292016024 Soft Story 3 12 427 MONTANA AVE 4293013027 Soft Story 2 24 511 MONTANA AVE 4293013024 Soft Story 3 8 724 MONTANA AVE 4292001002 Unreinforced Masonry 1 0 1013 MONTANA AVE (1007 MONTANA AVE)4280024018 Unreinforced Masonry 1 0 1112 MONTANA AVE 4281023026 Soft Story 2 0 1401 MONTANA AVE 4279033036 Unreinforced Masonry 1 0 1412 MONTANA AVE 4281009024 Steel Moment Frame 2 0 1421 MONTANA AVE 4279033031 Unreinforced Masonry 1 0 1426 MONTANA AVE 4281009068 Steel Moment Frame 2 0 1505 MONTANA AVE 4279026029 Steel Moment Frame 1 0 1523 MONTANA AVE 4279026002 Soft Story 2 0 1611 MONTANA AVE 4279025020 Unreinforced Masonry 1, 2 in rear 0 1711 MONTANA AVE (1711 MONTANA AVE/749 17TH ST)4279016020 Soft Story 2 4 1717 MONTANA AVE 4279016002 Soft Story 2 1 1724 MONTANA AVE 4277008029 Soft Story 3 17 1807 MONTANA AVE (1807 MONTANA AVE/751 18TH ST)4279015018 Soft Story 2 8 27 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1902 MONTANA AVE (1902-1904 MONTANA AVE)4277006014 Soft Story 2 4 1920 MONTANA AVE 4277006067 Soft Story 2 7 1925 MONTANA AVE 4279006020-026 Soft Story 3 7 2002-2010 MONTANA AVE 4277005015 Soft Story 2 6 2028 MONTANA AVE 4277005001 Unreinforced Masonry 1 0 2107 MONTANA AVE (755 21ST ST)4278030021-026 Soft Story 2 7 2121 MONTANA AVE (2117)4278030001 Soft Story 2 7 2153 MONTANA AVE 4278021003 Soft Story 2 5 2209 MONTANA AVE 4278021001 Soft Story 2 6 2214 MONTANA AVE 4277003012 Soft Story 2 2 2227 MONTANA AVE (2225-2227 MONTANA AVE)4278020010 Soft Story 2 3 2309 MONTANA AVE 4278011018 Soft Story 2 1 2512 MONTANA AVE 4277001013 Soft Story 2 12 2522 MONTANA AVE (2520, 2524)4277001002 Soft Story 2 0 3 2618 MONTANA AVE 4266013081-083 Soft Story 2 3 2622 MONTANA AVE 4266013057 Soft Story 2 5 2626 MONTANA AVE 4266013058 Soft Story 2 5 2632 MONTANA AVE 4266013059 Soft Story 3 6 2712 MONTANA AVE 4266013002 Soft Story 2 10 2812 MONTANA AVE 4266012002 Soft Story 2 5 631 NAVY ST 4287035021 Soft Story 2 4 639 NAVY ST 4287035012 Soft Story 2 3 3030 NEBRASKA AVE 4268010008 Steel Moment Frame 2 0 2700 NEILSON WAY 4288020036 Non-Ductile Concrete 16 266 2720 NEILSON WAY 4288020036 Non-Ductile Concrete 16 266 1320 OAK ST 4285010007 Soft Story 2 2 1343 OAK ST (1343-1345 OAK ST)4285003015 Soft Story 2 3 1802 OAK ST 4272002001 Soft Story 2 7 1809 OAK ST (1807-1809 OAK ST)4272001007 Soft Story 2 5 1817 OAK ST (1817-1819 OAK ST)4272001009 Soft Story 2 3 2004 OAK ST 4272002005 Soft Story 2 4 2005 OAK ST 4272001010 Soft Story 2 4 2026 OAK ST 4272002019 Soft Story 2 6 2107 OAK ST 4272008016 Soft Story 2 5 2117 OAK ST 4272008014 Soft Story 2 4 2120 OAK ST 4272009004 Soft Story 2 3 2127 OAK ST 4272008012 Soft Story 2 5 2128 OAK ST (2130)4272009006 Soft Story 2 4 2134 OAK ST 4272009029-033 Soft Story 2 5 2206 OAK ST 4272009008 Soft Story 2 6 2211 OAK ST 4272008020 Soft Story 2 5 2224 OAK ST 4272009022 Soft Story 2 5 2301 OAK ST 4272022019 Soft Story 2 6 2329 OAK ST 4272022014 Soft Story 2 2 2343 OAK ST (2345)4272022034-039 Soft Story 2 6 2347 OAK ST 4272022010 Soft Story 2 6 2401 OAK ST 4272023001 Soft Story 2 4 2402 OAK ST 4272020028 Soft Story 2 5 2414 OAK ST 4272020026 Soft Story 2 6 2418 OAK ST 4272020025 Soft Story 2 6 2424 OAK ST (2424-2428 OAK ST)4272020030-041 Soft Story 2 12 2443 OAK ST 4272023009 Soft Story 2 6 2462 OAK ST 4272020016 Soft Story 2 3 201 OCEAN AVE 4293019001-157 Non-Ductile Concrete 16 157 301 OCEAN AVE 4293003021 Soft Story 3 47 433 OCEAN AVE 4293007018 Soft Story 3 20 515 OCEAN AVE 4293008051-138, 4293008220 Steel Moment Frame 6 87 603 OCEAN AVE 4293015037-058 Unreinforced Masonry 6 22 633 OCEAN AVE 4293015001 Soft Story 3 31 28 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 701 OCEAN AVE 4293014169-188 4293014191-202 4293014207-210 Steel Moment Frame 4 36 757 OCEAN AVE 4293014036-086 Soft Story 4 51 801 OCEAN AVE 4292025022-053 Non-Ductile Concrete 6 32 849 OCEAN AVE 4292025010 Soft Story 4 63 915 OCEAN AVE 4292026026 Soft Story 3 21 923 OCEAN AVE 4292026019 Soft Story 2 8 933 OCEAN AVE 4292026017 Soft Story 2 12 1007 OCEAN AVE 4292027116-133 Non-Ductile Concrete 5 18 1299 OCEAN AVE 4291001034 Steel Moment Frame 11 0 1301 OCEAN AVE 4291014026 Non-Ductile Concrete 6 0 1401 OCEAN AVE 4291015030 Steel Moment Frame 3 0 1415 OCEAN AVE 4291015023 Steel Moment Frame 8 0 1431 OCEAN AVE 4291015026 Non-Ductile Concrete 15 288 1501 OCEAN AVE 4291028024 Steel Moment Frame 5 0 1535 OCEAN AVE (1537) 4291028025 Unreinforced Masonry 1 0 1541 OCEAN AVE 4291028017 Steel Moment Frame 3 0 1551 OCEAN AVE 4291028017 Steel Moment Frame 2 0 1646 OCEAN AVE (1646-1654 OCEAN AVE)4290018001 Soft Story 1 0 1660 OCEAN AVE 4290018012 Soft Story 3 18 1667 OCEAN AVE 4290015005 Soft Story 2 17 1670 OCEAN AVE 4290018013 Soft Story 3 12 1740 OCEAN AVE 4290019010 Non-Ductile Concrete 5 0 1760 OCEAN AVE 4290020039 Soft Story 3 17 1819 OCEAN AVE 4290020042 Non-Ductile Concrete 8 0 2101 OCEAN AVE 4289021053-069 Soft Story 3 17 2211 OCEAN AVE (2211-2217)4289022002 Soft Story 2 9 2221 OCEAN AVE 4289022056-077 Soft Story 4 22 2301 OCEAN AVE 4289023009 Soft Story 3 36 1633 OCEAN FRONT WALK 4290023900 Unreinforced Masonry 1 0 1647 OCEAN FRONT WALK 4290022007 Soft Story 3 18 1659 OCEAN FRONT WALK 4290022005 Soft Story 4 28 1910 OCEAN FRONT WALK 4289025001 Unreinforced Masonry 6 0 161 OCEAN PARK BLVD 4288019018 Soft Story 2 6 243 OCEAN PARK BLVD (243-251 OCEAN PARK BLVD)4287010048-052 Soft Story 3 5 611 OCEAN PARK BLVD (611 OCEAN PARK BLVD/2550 BEVERLEY AVE) 4287005003 Soft Story 2 8 632 OCEAN PARK BLVD 4287015022 Soft Story 3 12 646 OCEAN PARK BLVD (646-648 OCEAN PARK BLVD)4287015024 Soft Story 2 6 649 OCEAN PARK BLVD 4287003012 Soft Story 2 7 702 OCEAN PARK BLVD 4287016018 Soft Story 2 4 710 OCEAN PARK BLVD 4287016020 Soft Story 2 3 1007 OCEAN PARK BLVD 4284009009 Soft Story 2 6 1013 OCEAN PARK BLVD 4284009008 Soft Story 2 11 1017 OCEAN PARK BLVD 4284009007 Soft Story 2 7 1023 OCEAN PARK BLVD 4284009021 Soft Story 2 18 1047 OCEAN PARK BLVD 4284009001 Soft Story 2 4 1112 OCEAN PARK BLVD (1112-1114 OCEAN PARK BLVD)4285002007 Soft Story 2 6 1302 OCEAN PARK BLVD 4285003001 Soft Story 3 18 1515 OCEAN PARK BLVD 4284026804 Concrete Tilt-Up 2 0 1520 OCEAN PARK BLVD 4285004002 Soft Story 2 4 1711 OCEAN PARK BLVD 4273023031 Soft Story 2 0 1717 OCEAN PARK BLVD 4273023030 Soft Story 3 10 1723 OCEAN PARK BLVD 4273023029 Soft Story 3 10 1801 OCEAN PARK BLVD 4273020011 Soft Story 3 23 1802 OCEAN PARK BLVD 4272001001 Soft Story 2 7 2010 OCEAN PARK BLVD (2010-2016 OCEAN PARK BLVD)4272001016 Soft Story 2 12 2015 OCEAN PARK BLVD 4273019014 Soft Story 2 4 2021 OCEAN PARK BLVD (2021-2023 OCEAN PARK BLVD)4273019015 Soft Story 2 4 2121 OCEAN PARK BLVD 4273016012 Soft Story 3 6 29 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 2122 OCEAN PARK BLVD 4272008025 Soft Story 2 16 2125 OCEAN PARK BLVD (2125 OCEAN PARK BLVD/2610 22ND ST)4273016013 Soft Story 2 3 2310 OCEAN PARK BLVD 4272022002 Soft Story 2 5 2408 OCEAN PARK BLVD 4272023031 Soft Story 2 10 2410 OCEAN PARK BLVD 4272023036 Soft Story 3 7 2470 OCEAN PARK BLVD 4272023015 Soft Story 2 5 2525 OCEAN PARK BLVD 4270012048 Steel Moment Frame 2 0 2601 OCEAN PARK BLVD 4270012051 Steel Moment Frame 3 0 2601 OCEAN PARK BLVD 4270012051 Non-Ductile Concrete 2 0 2701 OCEAN PARK BLVD 4270014046 Steel Moment Frame 2 0 2716 OCEAN PARK BLVD 4272029005 Steel Moment Frame 3 0 2850 OCEAN PARK BLVD 4272029008 Steel Moment Frame 3 0 2900 OCEAN PARK BLVD 4272029008 Steel Moment Frame 2 0 3000 OCEAN PARK BLVD 4272029020 Steel Moment Frame 3 0 3000 OCEAN PARK BLVD 4272029020 Non-Ductile Concrete 4 0 3007 OCEAN PARK BLVD 4270021051 Unreinforced Masonry 1 0 3011 OCEAN PARK BLVD (3013)4270021051 Unreinforced Masonry 1 0 3100 OCEAN PARK BLVD 4272029019 Steel Moment Frame 3 0 3250 OCEAN PARK BLVD 4272029017 Concrete Tilt-Up 3 0 3340 OCEAN PARK BLVD 4272029027 Steel Moment Frame 3 0 3401 OCEAN PARK BLVD 4289008011 Soft Story 2 5 3420 OCEAN PARK BLVD 4272029015 Steel Moment Frame 3 0 929 OLYMPIC BLVD 4283004002 Concrete Tilt-Up 2 0 1131 OLYMPIC BLVD 4283006002 Concrete Tilt-Up 2 0 1301 OLYMPIC BLVD 4283008017 Unreinforced Masonry 1 0 1401 OLYMPIC BLVD (BLDG 1)4283010901 Concrete Tilt-Up 1 0 1401 OLYMPIC BLVD (BLDG 2)4283010901 Concrete Tilt-Up 1 0 1601 OLYMPIC BLVD 4283010004 Concrete Tilt-Up 1 0 2425 OLYMPIC BLVD 4268018047 Steel Moment Frame 6 0 3030 OLYMPIC BLVD 4268013021 Non-Ductile Concrete 4 0 402 PACIFIC ST 4289005038 Soft Story 3 7 612 PACIFIC ST 4289005087-090 Soft Story 2 4 631 PACIFIC ST 4289005009 Soft Story 2 6 643 PACIFIC ST 4289005008 Soft Story 2 5 649 PACIFIC ST 4289002049-052 Soft Story 2 4 707 PACIFIC ST 4284003015 Soft Story 2 9 835 PACIFIC ST 4284013001 Soft Story 2 1 1004 PACIFIC ST 4284013003 Soft Story 2 3 1012 PACIFIC ST 4284013004 Soft Story 2 5 1018 PACIFIC ST 4284013005 Soft Story 2 5 1022 PACIFIC ST 4284014012 Soft Story 2 4 1043 PACIFIC ST 4284013009 Soft Story 2 5 1044 PACIFIC ST 4293015030 Soft Story 3 12 125 PALISADES AVE 4291031035-037 Soft Story 2 3 1362 PALISADES BEACH ROAD (1362-1366 PALISADES BEACH ROAD)4284004021 Soft Story 2 5 821 PEARL ST 4284005010 Soft Story 2 12 822 PEARL ST (820-822 PEARL ST)4284005011 Soft Story 2 3 830 PEARL ST 4284004014 Soft Story 2 2 837 PEARL ST 4284013026-030 Soft Story 2 5 1017 PEARL ST 4284013018 Soft Story 2 3 1027 PEARL ST 4284012021 Soft Story 2 3 1033 PEARL ST 4284013017 Soft Story 2 4 1042 PEARL ST 4284013015 Soft Story 2 2 1043 PEARL ST 4284037018 Soft Story 2 6 1417 PEARL ST 4273021010 Soft Story 2 3 1826 PEARL ST 4273002900 Soft Story 2 4 1827 PEARL ST (1825-1827 PEARL ST)4273002020 Soft Story 2 5 1831 PEARL ST 4273018002 Soft Story 2 2 2008 PEARL ST 4270010011 Soft Story 2 2 30 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 3403 PEARL ST (3401-3403 PEARL ST)4268005018 Soft Story 2 6 2100 PENNSYLVANIA AVE (1701 21ST ST)4275030011 Concrete Tilt-Up 2 0 3107 PENNSYLVANIA AVE 4289026008 Soft Story 3 68 1 PICO BLVD 4290021007 Non-Ductile Concrete 7 0 110 PICO BLVD 4289003029 Soft Story 2 10 150 PICO BLVD (154) (144)4289020004 Unreinforced Masonry 1 0 530 PICO BLVD 4289011043 Non-Ductile Concrete 12 0 612 PICO BLVD 4289003028 Soft Story 2 10 618 PICO BLVD 4284001012 Soft Story 2 6 701 PICO BLVD 4290004013 Unreinforced Masonry 1 0 826 PICO BLVD 4284001008 Unreinforced Masonry 2 0 828 PICO BLVD 4284001040 Unreinforced Masonry 1 0 844 PICO BLVD 4283021017 Soft Story 2 0 901 PICO BLVD 4283021019 Unreinforced Masonry 1 0 913 PICO BLVD 4284016004 Soft Story 2 1 1020 PICO BLVD 4283027023 Soft Story 3 20 1211 PICO BLVD 4284033003-004 Soft Story 2 11 1320 PICO BLVD 4274019022 Soft Story 2 27 1905 PICO BLVD 4273003006 Soft Story 2 0 2028 PICO BLVD (2028-2030 PICO BLVD)4274032016 Soft Story 2 0 2115 PICO BLVD 4274024907 Concrete Tilt-Up 1 0 2828 PICO BLVD 4270004043 Unreinforced Masonry 1 0 2917 PICO BLVD 4274033015 Soft Story 2 4 3021 PICO BLVD 4274033024 Soft Story 2 0 3105 PICO BLVD (3105-3107 PICO BLVD)4289003024 Soft Story 2 1 608 PICO PL 4289003041 Soft Story 2 2 615 PICO PL 4289003043 Soft Story 2 3 625 PICO PL 4287026017 Soft Story 3 8 171 PIER AVE (169-177)4288008008 Unreinforced Masonry 2 0 511 PIER AVE 4287027029 Soft Story 3 6 521 PIER AVE 4287027030 Soft Story 3 6 538 PIER AVE 4287026062-066 Soft Story 3 5 602 PIER AVE 4287029033-036 Soft Story 3 4 631 PIER AVE 4287029016 Soft Story 2 4 638 PIER AVE 4287029024 Soft Story 3 5 653 PIER AVE 4287030050-053 Soft Story 3 4 720 PIER AVE 4287030026 Soft Story 2 4 733 PIER AVE 4285029027-028 Soft Story 3 7 820 PIER AVE 4285028016 Soft Story 2 2 823 PIER AVE 4285028018 Soft Story 2 3 831 PIER AVE 4285028019 Soft Story 2 3 1001 PIER AVE 4285029022 Soft Story 3 3 1004 PIER AVE 4285029021 Soft Story 2 2 1014 PIER AVE 4287001026 Soft Story 2 3 727 PINE ST 4284006005 Soft Story 2 5 817 PINE ST 4284011008 Soft Story 2 1 1017 PINE ST 4284011002 Soft Story 2 1 1043 PINE ST 4266014021 Soft Story 2 1 924 PRINCETON ST 4266016043 Soft Story 2 4 1123 PRINCETON ST 4267007039-057 Soft Story 2 19 1222 PRINCETON ST 4267006029 Soft Story 3 6 1229 PRINCETON ST 4267007031 Soft Story 3 10 1230 PRINCETON ST 4267007013 Soft Story 2 1 1240 PRINCETON ST 4267007017 Soft Story 2 6 1256 PRINCETON ST 4267008023 Soft Story 2 3 1258 PRINCETON ST (2623-29 ARIZONA AVE)4267007033-037 Soft Story 2 5 1306 PRINCETON ST 4267008072-093 Soft Story 3 22 1320 PRINCETON ST 4267020015 Soft Story 2 4 1421 PRINCETON ST 4267020016 Soft Story 2 6 1425 PRINCETON ST 4267021024 Soft Story 2 6 31 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1426 PRINCETON ST 4267021022 Soft Story 2 6 1434 PRINCETON ST 4267020020 Soft Story 2 5 1441 PRINCETON ST 4267020019 Soft Story 2 6 1443 PRINCETON ST 4267021020 Soft Story 2 3 1444 PRINCETON ST 4267021018 Soft Story 2 6 1449 PRINCETON ST 4267020021 Soft Story 2 6 1451 PRINCETON ST 4267020022 Soft Story 2 6 1454 PRINCETON ST 4267021027 Soft Story 2 2 1458 PRINCETON ST 4267023024 Soft Story 2 6 1507 PRINCETON ST 4267023022 Soft Story 2 6 1517 PRINCETON ST 4267023021 Soft Story 2 6 1523 PRINCETON ST 4267022036-043 Soft Story 2 8 1528 PRINCETON ST (1528-1530 PRINCETON ST)4267023054-059 Soft Story 2 6 1533 PRINCETON ST 4287020005 Soft Story 2 6 436 RAYMOND AVE 4287020031 Soft Story 3 20 440 RAYMOND AVE 4287021066-075 Soft Story 3 10 441 RAYMOND AVE 4287021024 Soft Story 3 11 501 RAYMOND AVE 4287020032 Soft Story 3 20 518 RAYMOND AVE 4287017009 Soft Story 3 13 720 RAYMOND AVE 4287031034 Soft Story 2 1 3016 RUSKIN ST 4293003001 Soft Story 2 28 132 SAN VICENTE BLVD (130-132 SAN VICENTE BLVD)4293003007 Soft Story 3 20 302 SAN VICENTE BLVD (302-304 SAN VICENTE BLVD)4293003008 Soft Story 3 22 316 SAN VICENTE BLVD 4293003009 Soft Story 3 17 326 SAN VICENTE BLVD 4293002031-050 Soft Story 3 20 323 SAN VICENTE BLVD 4293001028 Soft Story 3 17 401 SAN VICENTE BLVD 4293004002 Soft Story 3 24 416 SAN VICENTE BLVD 4293004152 Soft Story 2 6 424 SAN VICENTE BLVD (424-438 SAN VICENTE BLVD)4293001025 Soft Story 2 14 435 SAN VICENTE BLVD 4293001022 Soft Story 2 20 451 SAN VICENTE BLVD 4293004035-064 Soft Story 4 30 516 SAN VICENTE BLVD 4293004009 Soft Story 3 8 522 SAN VICENTE BLVD 4293004012 Soft Story 3 27 608 SAN VICENTE BLVD 4293004014 Soft Story 3 24 630 SAN VICENTE BLVD 4267021005 Soft Story 2 0 101 SANTA MONICA BLVD (1341 OCEAN AVE)4291014025 Unreinforced Masonry 3 0 116 SANTA MONICA BLVD (116-134) (1402 2ND ST)4291015001 Unreinforced Masonry 2 0 200 SANTA MONICA BLVD (202)4291016018 Unreinforced Masonry 2 0 201 SANTA MONICA BLVD 4291013023 Non-Ductile Concrete 6 0 301 SANTA MONICA BLVD 4291012010 Unreinforced Masonry 4 0 318 SANTA MONICA BLVD 4291017002 Unreinforced Masonry 1 w/mezz 0 332 SANTA MONICA BLVD (1410 4TH ST)4291017001 Unreinforced Masonry 1 0 401 SANTA MONICA BLVD (401-415)4291011010 Unreinforced Masonry 2 0 429 SANTA MONICA BLVD 4291011009 Steel Moment Frame 7 0 501 SANTA MONICA BLVD 4291010023 Steel Moment Frame 7 0 502 SANTA MONICA BLVD 4291019024 Unreinforced Masonry 4 0 610 SANTA MONICA BLVD (606-616)4291020022 Unreinforced Masonry 2 0 700 SANTA MONICA BLVD (1407 7TH ST)4291021027 Unreinforced Masonry 1 0 701 SANTA MONICA BLVD 4291008016 Steel Moment Frame 3 0 717 SANTA MONICA BLVD 4291008014 Unreinforced Masonry 2 0 919 SANTA MONICA BLVD 4282011900 Steel Moment Frame 3 0 920 SANTA MONICA BLVD (920-928)4282026001 Unreinforced Masonry 3 0 1002 SANTA MONICA BLVD 4282025027 Unreinforced Masonry 2 0 1127 SANTA MONICA BLVD (1117)4282013024 Unreinforced Masonry 2 0 1221 SANTA MONICA BLVD (1229)4282014012 Unreinforced Masonry 1 0 1434 SANTA MONICA BLVD (1430)4282021001 Unreinforced Masonry 3 0 1501 SANTA MONICA BLVD 4282017013 Unreinforced Masonry 1 0 1631 SANTA MONICA BLVD (1623)4282018011 Unreinforced Masonry 1, portions are 2 0 1702 SANTA MONICA BLVD 4275011025 Non-Ductile Concrete 2 0 32 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1717 SANTA MONICA BLVD 4276030025 Steel Moment Frame 2 0 1801 SANTA MONICA BLVD 4276029048 Unreinforced Masonry 1 0 1905 SANTA MONICA BLVD (1909)4276028013 Unreinforced Masonry 1 0 1919 SANTA MONICA BLVD 4276028035 Steel Moment Frame 4 0 2001 SANTA MONICA BLVD 4276027015 Steel Moment Frame 12 0 2020 SANTA MONICA BLVD 4275008016 Steel Moment Frame 6 0 2020 SANTA MONICA BLVD 4275008016 Non-Ductile Concrete 3 0 2021 SANTA MONICA BLVD 4276026017 Steel Moment Frame 7 0 2300 SANTA MONICA BLVD 4275005001 Unreinforced Masonry 1 0 2301 SANTA MONICA BLVD 4276024035 Unreinforced Masonry 1 0 2336 SANTA MONICA BLVD 4275004029 Steel Moment Frame 3 0 2428 SANTA MONICA BLVD 4275003016 Non-Ductile Concrete 4 0 2610 SANTA MONICA BLVD (2610-2612 SANTA MONICA BLVD)4267008004 Soft Story 2 1 2619 SANTA MONICA BLVD 4267018004 Soft Story 2 4 2630 SANTA MONICA BLVD (2632)4267021001 Unreinforced Masonry 2 0 2917 SANTA MONICA BLVD 4267011024 Unreinforced Masonry 2 0 2922 SANTA MONICA BLVD 4267012003 Soft Story 2 3 3011 SANTA MONICA BLVD 4288020041-054 4288020057-070 4288020073-085 4288020238-239 Soft Story 3 43 1 SEA COLONY DR (1-43 SEA COLONY DR)4290018004 Soft Story 3 8 30 SEASIDE TER 4290020034 Soft Story 3 11 6 SEAVIEW TER 4290020035 Soft Story 3 3 12 SEAVIEW TER 4290020036 Soft Story 2 2 16 SEAVIEW TER 4290020038 Soft Story 2 3 40 SEAVIEW TER 4266008067 Soft Story 2 5 1165 STANFORD ST 4267004011 Soft Story 2 9 1224 STANFORD ST 4267003010 Soft Story 2 15 1239 STANFORD ST 4267004001 Soft Story 2 6 1250 STANFORD ST 4267012085-098 Soft Story 2 14 1315 STANFORD ST (1315-1317 STANFORD ST)4267011008 Soft Story 2 7 1322 STANFORD ST 4267011009 Soft Story 2 6 1326 STANFORD ST 4267012067-073 Soft Story 2 7 1327 STANFORD ST 4267012010 Soft Story 2 5 1337 STANFORD ST 4267018027-033 Soft Story 2 7 1415 STANFORD ST 4267017001 Soft Story 2 0 1418 STANFORD ST 4267017051-056 Soft Story 2 6 1431 STANFORD ST 4267017057-062 Soft Story 2 6 1437 STANFORD ST 4267017063-068 Soft Story 2 6 1445 STANFORD ST 4267017069-075 Soft Story 2 7 1447 STANFORD ST 4267017076-082 Soft Story 2 7 1453 STANFORD ST 4267026013 Soft Story 2 4 1531 STANFORD ST 4267026017 Soft Story 2 7 1543 STANFORD ST 4274028010 Soft Story 2 4 2037 STEWART ST (2037-2039 STEWART ST)4274008043 Soft Story 2 3 2116 STEWART ST 4274008078-082 Soft Story 2 5 2138 STEWART ST (2136-2138 STEWART ST)4289022006 Soft Story 2 7 103 STRAND ST (101-103 STRAND ST)4289022007 Soft Story 3 10 117 STRAND ST 4289014011 Soft Story 3 7 305 STRAND ST 4289006014-028 Soft Story 2 15 608 STRAND ST (608-610 STRAND ST)4289005061-064 Soft Story 2 4 617 STRAND ST 4289005045-052 Soft Story 3 8 627 STRAND ST (627-631 STRAND ST)4289005024 Soft Story 2 2 647 STRAND ST (647-647 1/2 STRAND ST)4289001022 Soft Story 2 3 703 STRAND ST 4289001026 Soft Story 2 5 721 STRAND ST 4274030017 Soft Story 2 1 2911 URBAN AVE 4290020024 Soft Story 2 1 9 VICENTE TER 4290020020 Soft Story 2 2 41 VICENTE TER 4274020005 Soft Story 2 5 33 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 2023 VIRGINIA AVE 4274020006 Soft Story 2 6 2027 VIRGINIA AVE 4274023041-054 Soft Story 3 14 2241 VIRGINIA AVE 4274004028 Soft Story 2 8 2520 VIRGINIA AVE 4268023010 Soft Story 2 4 1808 WARWICK AVE (1808-1812 WARWICK AVE)4292026011 Soft Story 3 12 120 WASHINGTON AVE 4292027002 Unreinforced Masonry 1 1 125 WASHINGTON AVE 4292022001 Soft Story 3 24 205 WASHINGTON AVE 4292023010 Unreinforced Masonry 5 44 222 WASHINGTON AVE 4292015013 Soft Story 4 15 401 WASHINGTON AVE (401 WASHINGTON AVE/957 4TH ST)4292014001 Soft Story 3 8 420 WASHINGTON AVE 4292015012 Soft Story 3 11 425 WASHINGTON AVE 4292011021 Soft Story 2 8 510 WASHINGTON AVE (510 WASHINGTON AVE/1005 5TH ST)4292007013 Soft Story 3 10 625 WASHINGTON AVE 4292002012 Soft Story 2 7 703 WASHINGTON AVE (703 WASHINGTON AVE/957 7TH ST)4281034034-039 Soft Story 4 6 802 WASHINGTON AVE (802-812 WASHINGTON AVE)4281034003 Soft Story 2 4 820 WASHINGTON AVE 4281033011 Soft Story 3 16 825 WASHINGTON AVE 4281029001 Soft Story 2 3 920 WASHINGTON AVE (920 WASHINGTON AVE/1004 10TH ST)4281017118-127 Soft Story 3 10 1201 WASHINGTON AVE (1201-1207)4281017013 Soft Story 2 7 1225 WASHINGTON AVE 4281010012 Soft Story 2 6 1421 WASHINGTON AVE (1421-1423 WASHINGTON AVE)4277027021 Soft Story 2 4 1724 WASHINGTON AVE 4277024049-059 Soft Story 2 11 2000 WASHINGTON AVE 4277024020 Soft Story 3 6 2020 WASHINGTON AVE 4277013075 Soft Story 3 6 2101 WASHINGTON AVE 4277018003 Soft Story 2 1 2522 WASHINGTON AVE 4276017045 Soft Story 2 0 100 WILSHIRE BLVD 4291001035 Non-Ductile Concrete 21 0 101 WILSHIRE BLVD (1132 2ND ST)4292028001 Concrete Tilt-Up 1 0 120 WILSHIRE BLVD (122)4291001036 Unreinforced Masonry 2 0 201 WILSHIRE BLVD 4292021019 Non-Ductile Concrete 3 0 233 WILSHIRE BLVD 4292021022 Non-Ductile Concrete 10 0 308 WILSHIRE BLVD 4291003025 Steel Moment Frame 2 0 309 WILSHIRE BLVD 4292020004 Non-Ductile Concrete 2 0 312 WILSHIRE BLVD 4291003021 Non-Ductile Concrete 2 0 315 WILSHIRE BLVD (307-315)4292020012 Unreinforced Masonry 2 0 400 WILSHIRE BLVD (400-412)4291004015 Unreinforced Masonry 2 0 401 WILSHIRE BLVD 4292013029 Steel Moment Frame 12 0 419 WILSHIRE BLVD 4292013020 Unreinforced Masonry 1 0 520 WILSHIRE BLVD (518-522)4291005003 Unreinforced Masonry 2 0 530 WILSHIRE BLVD 4291005023 Steel Moment Frame 4 0 530 WILSHIRE BLVD 4291005023 Unreinforced Masonry 4 0 702 WILSHIRE BLVD 4291007026 Non-Ductile Concrete 6 0 815 WILSHIRE BLVD (815-823)4281035024 Unreinforced Masonry 3 0 900 WILSHIRE BLVD 4282008071 Steel Moment Frame 3 0 901 WILSHIRE BLVD 4281028060 Steel Moment Frame 3 0 1201 WILSHIRE BLVD 4281019010 Unreinforced Masonry 1 0 1217 WILSHIRE BLVD 4281019026 Unreinforced Masonry 1 0 1314 WILSHIRE BLVD 4282004022 Non-Ductile Concrete 2 0 1401 WILSHIRE BLVD 4281011028 Unreinforced Masonry 1 0 1411 WILSHIRE BLVD (1415)4281011026 Unreinforced Masonry 1 0 1417 WILSHIRE BLVD (1423)4281011025 Unreinforced Masonry 1 0 1433 WILSHIRE BLVD 4281011011 Unreinforced Masonry 1 0 1505 WILSHIRE BLVD 4281005026 Unreinforced Masonry 2 0 1511 WILSHIRE BLVD 4281005025 Unreinforced Masonry 2 0 1529 WILSHIRE BLVD 4281005011 Unreinforced Masonry 1 0 1626 WILSHIRE BLVD 4282001034 Non-Ductile Concrete 2 0 1801 WILSHIRE BLVD (1801 -1831)4276009036 Steel Moment Frame 6 0 1902 WILSHIRE BLVD 4276013020 Unreinforced Masonry 1 0 34 Potentially Seismically Vulnerable Buildings - Unretrofitted Attachment C 1908 WILSHIRE BLVD 4276013030 Unreinforced Masonry 1 0 2001 WILSHIRE BLVD 4276007035 Steel Moment Frame 7 0 2121 WILSHIRE BLVD 4276006022 Steel Moment Frame 4 0 2406 WILSHIRE BLVD (2408)4276017043 Unreinforced Masonry 1 0 2414 WILSHIRE BLVD (2414-2416 WILSHIRE BLVD)4267004047-060 Soft Story 3 14 2421 WILSHIRE BLVD 4276003004 Unreinforced Masonry 1, 2 in rear 0 2444 WILSHIRE BLVD 4276019031 Steel Moment Frame 7 0 2721 WILSHIRE BLVD (2723)4266016050 Unreinforced Masonry 1 0 2730 WILSHIRE BLVD 4267006046 Steel Moment Frame 6 0 2811 WILSHIRE BLVD 4266009060 Steel Moment Frame 9 0 2828 WILSHIRE BLVD (2838)4267005009 Concrete Tilt-Up 1 0 2901 WILSHIRE BLVD 4266009039 Non-Ductile Concrete 4 0 3016 WILSHIRE BLVD 4267003001 Non-Ductile Concrete 5 0 3130 WILSHIRE BLVD 4267002025 Non-Ductile Concrete 6 0 1237 YALE ST (1237-1243 YALE ST)4267005015 Soft Story 3 68 1240 YALE ST 4267010062-067 Soft Story 2 6 1330 YALE ST 4267010013 Soft Story 2 6 1336 YALE ST 4267011028 Soft Story 2 10 1341 YALE ST 4267010009 Soft Story 2 4 1342 YALE ST 4267019059-065 Soft Story 2 7 1421 YALE ST 4267018010 Soft Story 2 6 1432 YALE ST 4267018016 Soft Story 2 6 1437 YALE ST 4267019034-040 Soft Story 3 7 1442 YALE ST 4267018020 Soft Story 2 3 1447 YALE ST 4267019021 Soft Story 2 7 1448 YALE ST (1446-1448 YALE ST)4267024031 Soft Story 2 10 1502 YALE ST (1502-1506 YALE ST)4267025006 Soft Story 2 7 1511 YALE ST (1511-1515 YALE ST)4267025008 Soft Story 2 3 1517 YALE ST 4267025012 Soft Story 2 7 1527 YALE ST 4267024016 Soft Story 2 3 1532 YALE ST 4267025016 Soft Story 3 7 1535 YALE ST (1535-1537 YALE ST)4267025017 Soft Story 3 7 1545 YALE ST (1541-1545 YALE ST)4267024030 Soft Story 2 5 1548 YALE ST (1548 YALE ST/2835 COLORADO)4267025020 Soft Story 2 3 1551 YALE ST 4274032022 Soft Story 2 4 2217 YORKSHIRE AVE (2217 YORKSHIRE AVE/2901 PICO BLVD)4274032022 Soft Story 2 4 35 1 Vernice Hankins From:Bill Dawson <bdawson@linkline.com> Sent:Monday, February 13, 2017 2:12 PM To:Gleam Davis; Ted Winterer; Tony Vazquez; Kevin McKeown Fwd; Sue Himmelrich; Pam OConnor; Terry O’Day Cc:councilmtgitems; Tracy Condon Subject:FW: Santa Monica Revision to Seismic Retrofit Standards Dear  Mr. Takiguchi  and  All  Santa  Monica  City  Council  Memb ers:   Thank  you  for  the  thoughtful  approach  Mr. Takiguchi’s   team  has  put  into  the  proposed  revision  to  the  existing  Seismic   Retrofit  Standards.   My  collogues  in  the  housing  industry, fellow  apartment  association  members  and  clients  are  in  the   process  of  reviewing  the  proposed  revisions  and  have  a  major  concern.   The  significant  con c ern  that  I  would  like  to  bring  to  your  attention  which  is  the  recording  of  a  public  notice  with  the   county  recorder  which  intended  to  advise  and  protect  the  tenants  and  public  may  have  devastating  unintended   consequences.   If  the  notice  copies  the  example  of  another  city  an d  uses  the  ti tle  “Notice  of  Substandard  Condition”  instead  of  a  more  general  term  such  as  “Notice  of  Seismic  Retrofit  Requirement” it  may  trigger  a  default  of  a  property   owners  loan.   Additionally, according  to  three  lenders  I  consulted  with  it  would  make  re ‐financing  a  property  almost   impossible  thus  preventing  an  owner  from  obtaining  funds  needed  to  retrofit  a  property .   I  urge  you  to  consider  1.) not  requiri ng  the  recordation  of  a  notice  on  a  property; or  2.) modifying  the  title  of  the  notice   to  read  “Notice  of  Seismic  Retrofit  Requirement” or  some  similar  language.  This  would  put  the  tenants  and  public  on   notice  and  still  allow  a  property  owner  to  refinance  a  property  to  obtain  f unds  needed  to  comply  with  th e  retrofit   requirements.   Respectfully  Submitted,   Bill  Dawson, V.P.  Sullivan  Dituri  Real  Estate  & Mgmt. Co.  2111  Wilshire  Blvd.   Santa  Monica, CA  90403   Past  President  of  the  Apt. Assoc. of  Greater  Los  Ange les   Current  Board  Memb er    www.AAGLA.org    Item 7-A 02/14/17 1 Item 7-A 02/14/17 (310) 656-4311 February 13, 2017 VIA E-MAIL Santa Monica City Council 1685 Main Street, Room 102 Santa Monica, CA 90401 Re: Seismic Retrofit Program Draft Ordinance Hearing Date: February 14, 2017 Agenda Item No. 7 -A Dear Councilmembers : This letter is submitted on behalf of several owners of buildings that a re on the City’s list of Potentially Seismically Vulnerable Buildings. Overall, we are concerned that most affected building owners have not had an opportunity to review and provide input on the draft Ordinance as our understanding is that Tuesday’s public hearing has not been individually noticed to the owners on the City’s list of Potentially Seismically Vulnerable Buildings. Nonetheless, we appreciate City Staff’s hard work in developing the Seismic Retrofit Program and want to ensure it is successful. With this in mind, we are writing to request that the City Council revise the draft Seismic Retrofit Ordinance in five limited, but important, ways in order to make the program more workable upon implementation and avoid unintended consequences. We have explained the five requested changes below and attached a document that includes our proposed specific language changes to the draft Ordinance. 1. The time limits for submitting a building permit application for the retrofit and completing the retrofit should not run while either (a) the C ity is reviewing the structural report to determine if a retrofit is necessary and/or the scope of the retrofit or (b) the Ci ty is reviewing the retrofit plans during the plan check process. As the Ordinance is currently drafted, all time periods for compliance, including those to file for a building permit and complete the retrofit, run from the date the City officially notifies a building owner that their building is on the City’s list of Po tentially Seismically Vulnerable Buildings. T his is unworkable because the time period s to file for a building permit and complete the retrofit include time expended in City review that is not within the building owner’s control. plarmore@hlkklaw.com Item 7-A 02/14/17 1 Item 7-A 02/14/17 Instead , we ask that th e City Council revise the time periods for filing the building permit application and completing the retrofit to run from later milestones in order to account for the time it will take City Staff to (a) review the structural report and (b) review the building permit application and plans and issue the building permit. We think this is especially important given that the Ordinance does not mandate time periods for City Staff to complete its review of structural reports or to plan check building permits rela ted to seismic retrofits. And, given the additional volume of work this Ordinance will create for City Staff, the City’s review periods may prove to be much lengthier than anticipated. Specifically, we propose the following : a. The time limit for a building owner to file a building permit application for a required seismic retrofit should run from the date the City determines that a retrofit is required (after the City has completed its review of the structural report). Absent this change, the bui lding owner’s time period for filing a building permit would be running while the City is reviewing the building owner’s structural evaluation to determine if the retrofit is required (and before the building owner knows if the retrofit will be required or, in some cases, the scope of the work that is required). Given that the City’s timetable for review of the report is out of the building owner’s control, we do not think it is fair and may lead to compliance issues if the time period for filing a buildin g permit application is based on when the City’s initial notice is sent. For example, as currently drafted property owners with Unreinforced Masonry Buildings must submit a structural evaluation report to the City within 3 months of being noticed and, if the City determines a retrofit is required, file for a building permit application within 6 months of being noticed. Given the time it takes to prepare the construction documents and other supplemental materials required for a building permit applicatio n, it would be very difficult (if not impossible) to comply with the 6 -month time period if the City does not determine the retrofit is needed for weeks or months after the structural report is filed. b. The time limit for “Final Approval” (which we assume is completion of the Seismic Retrofit work) should run from the date the City issues the building permit for the seismic retrofit work . Absent this change, the property owner’s time period for completing the retrofit would be running while both (a) the City is reviewing the property owner’s structural Item 7-A 02/14/17 1 Item 7-A 02/14/17 evaluation and (b) the City is reviewing the retrofit plans during the plan check process. Given that the City’s timetable for review of the report and retrofit plans are out of the property owner’s control, we do not think it is fair and may lead to compliance issues if the time period for completing the retrofit is based on when the City’s initial notice is sent. The plan check process is lengthy and can be delayed for any number of reasons given the number of people required to sign -off on every round of plan check (e.g. a plan check in a particular department can be held up for weeks if the particular plan checker goes on leave or retires and the plan check is not assigned). Thus, it makes sense to wait to start the time period for Final Approval until the building permit for the seismic work is issued. If the City is not supportive of the time period for Final Approval running from issuance of the building permit for the seismic retrofit work, this t ime period should instead run from the date the City determines that a retrofit is required (after the City has completed its review of the structural report) and this time period should be tolled while the plan check process in ongoing. We appreciate that draft Ordinance Section 8.58.090 provides the Planning Director (and Hearing Examiner on appeal) with the authority to grant extensions; however, we do not think it should be necessary for a building owner to apply for (or the City to process) extensi o ns in the circumstances described above. Instead, it would be simpler and more fair to ensure that the City’s review periods are not included in the applicant’s time to file building permit plans and complete the retrofit. 2. The Ordinance should allow more time for sub mitting a building permit application and completing the retrofit if the retrofit requires exterior modifications to a building that require design review. Presumably a t least some retrofit projects will require exterior modifications to buildings that will trigger design review (either by the Architectural Review Board or Landmarks Commission). Given that the draft Ordinance does not propose to exempt retrofit projects from design review, we request that the draft Ordinance be revised t o indicate that both (a) the time period to file for a building permit and (b) the time period to complete the retrofit are tolled while the design review process is ongoing (including a reasonable amount of time to prepare the application and supportive m aterials). Item 7-A 02/14/17 1 Item 7-A 02/14/17 3. City S taff should have the ability to impose conditions on granting extensions, including with respect to extensions granted because a building is proposed for demolition as part of pending entitlements for redevelopment of a property. We support City Staff’s ability to grant extensions for good cause as provided in draft Ordinance Section 8.58.090. Because some of the buildings on the retrofit list are slated for demolition pending City entitlements for redevelopment of a property, w e request confirmation from City Staff that “good cause” includes an extension to allow for the City to make a determination regarding the pending entitlements/demolition of a building. With this in mind, we think it would be helpful to clarif y that the Pla nning Director (and Hearing Examiner on appeal) can impose conditions when granting an extension to tailor it to the particular circumstances. 4. City Staff’s ability to approve reduced parking resulting from a retrofit should not be limited to a specifi ed number/percentage. We request that the Council revise Section 8.58.100 of the draft Ordinance to provide Staff with greater discretion with respect to approving reduced parking that is a result of a retrofit. In order to allow Staff to approve reduced parking, the draft Ordinance provides that the building owner must show that there is no other practicable method to complete the required retrofit without the reduction. Given this and that a building owner likely has every incentive to keep as much p arking as possible, we do not think Staff’s discretion with respect to the number of parking spaces that can be eliminated needs to be limited to a specific number /percentage in the Ordinance . 5. The Ordinance should be clear that new requirements in the City’s Zoning Ordinance, including the Trash Screening and Enclosure Requirements , are not triggered by a Retrofit Project. As currently drafted, Section 8.58.120 of the draft Ordinance implies that the new and onerous Resource Recovery and Recycling Standards in the 2015 Zoning Ordinance could be triggered by a retrofit. We do not think it would be appropriate for the City to require those undergoing the burden and cost of seismically retrofitting their buildings to comply with new Resource Recovery and Recycling Standards or negotiate with the Resource Recovery and Recycling Staff over the extent to which the City can require additional Resource Recovery and Recycling space or associated staging as part of the seismic retrofit project. Thus, we request that this section be revised to specifically indicate that the City’s new Resource Recovery and Recycling Standards are not triggered for seismic retrofit projects. Item 7-A 02/14/17 1 Item 7-A 02/14/17 Thank you for your time and consideration of these important issues. Sincerely, Paula J. Larm ore Enclosure cc: Rick Cole Elaine Polachek David Martin Ron Takiguchi Joseph Lawrence Item 7-A 02/14/17 1 Item 7-A 02/14/17 Proposed Changes to Seismic Retrofit Ordinance 1. Proposed changes to T ime L imits for C ompliance Sections 8.60.050, 8.64.070, 8.72.060, 8.76.080, and 8.80.060 : Action by Building Owner Time Limits from Date of Service of Order Structural Evaluation Report 90 Days / or 3 Months from Date of Service of Order Application for Building Permit and Submission of Plans 180 Days / or 6 Months from City Determination that Retrofit is Required after City review of the Structural Evaluation Report Submitted by Owner Final Approval 2 Years / or 24 Months from Issuance of Building Permit for Retrofit 2. Prop osed new Section 8.58.140 Changes that Require Exterior Modifications to Buildings : “Section 8.58.140 Changes that Require Exterior Modifications to Buildings Construction projects undertaken for the purpose of complying with the Santa Monica Seismic Retrofit Laws that require one or more exterior modifications to the building and require design by the Architectural Review Board or Landmarks Commission shall have both the time periods for (a) application of building permit and submission of plans and (b) final approval of the retrofit tolled during the time period between the design review application being filed and the design review application being approved as well as a reasonable time period to prepare the application and supportive materials .” 3. Proposed changes to Section 8.58 .090 Extensions: “(a) Notwithstanding any other provisions of this Code, extensions of time from the stated time limits set forth in the Santa Monica Seismic Retrofit Laws may be granted for good cause, provided that the bu ilding owner files a written req uest with the Director of Planning and Community Development or designee. In granting an extension of time pursuant to this Section , the Director of Planning and Community Development (or his/her d esignee ) may impose conditions of approval.” Item 7-A 02/14/17 1 Item 7-A 02/14/17 4. P roposed change to Section 8.58.100 Parking Requirements : “Notwithstanding any other provisions of this Code to the contrary, the Zoning Administrator, or designee, may reduce the size of required parking spaces and/or the number of required parking spaces, to the minimum extent necessary, to achieve compliance wi th the requirements of the Santa Monica Seismic Retrofit Laws, if the building owner can show that there is no practicable method to complete the required retrofit without the reduction. The reduction in parking spaces shall not exceed 20% of required parking spaces or one (1) space, whichever is greater. Nothing in this section shall be intended to reduce, change, or eliminate an owner's obligations under the Rent Control laws.” 5. Proposed change s to Section 8.58.120 Trash Screening and Enclosure Requir ements : “Notwithstanding any other provisions of this Code to the contrary, general requirements in Chapter 9 of the Santa Monica Municipal Code which would otherwise apply to any construction for which a building permit is required, including the City’s refuse and recycling standard s (Section 9.21.130), shall not apply to construction projects undertaken for the purpose of complying with the Santa Monica Seismic Retrofit Laws.the Public Works Director, or designee, may waive or reduce the requireme nts of Section 9.21.130 (Resource Recovery and Recycling Standards) of this Code, to the minimum extent necessary, if the building owner can show that there is no practicable method to complete the required retrofit and comply with Section 9.21.130 .” Item 7-A 02/14/17 1 Item 7-A 02/14/17 1 Vernice Hankins From:IPM.LLC@earthlink.net Sent:Monday, February 13, 2017 9:10 PM To:councilmtgitems Subject:quake retrofitting recommendations 2/13/2017 7:32:48 PM Jay Johnson 9th and Alta Congratulations to Ron Takeguchi, Gustav and staff for great job. As building/safety commissioner Don Gray said: "This is much more complicated than I thought!" In real estate, its location location location. In retrofitting its share share share. Condo and building owners are legally mandate d to share by paying roughly $15,000 per parking space. 10 spaces $150,000. Planning can share by appointing an ombudspe rson to guide owners through the permit process. City manager can share by forming an in teragency and stake holders working group. Finance can share by floati ng a $200 million construction bond. 1% interest on muni bonds compared to 5% on 2n d trust deeds, reduces costs and pass thrus to tenants. 30 year loan term repayments could be on pr operty tax bills, thus future owners would continue payments is property is sold. Finance can coordinate with county assessor to eliminate increased assessed valuation for construction costs reducing the pass thru to tenants. Planning can share by fee reductions. 2 soils reports at $2000 each not needed. Waste management can share by suspending trash recycle deposits. ARB can share by suspending the rule whereby, if 50% of the exterior is removed, it triggers code upgrades of new water meters at $5000 and interior fire sprinklers at $10,000. Building and Safety can share by listing structural engineer s and contractors. Code Compliance can share by suspending enforcement of non-emergency issues on in- process retrofitting projects. Renters can share by paying a portion of this legally manda ted requirement that may be required by state law. Item 7-A 02/14/17 1 Item 7-A 02/14/17 2 Tenants can share by cooperation with constr uction discomforts regarding parking, noise, and garage storage. Rent control can share with solutions to cons truction issues replacing the adversarial process with problem solving meetings. share share share-- we're all in this together! thank you . Jay Johnson 310-488-7431 I have more: 100% write off in same year, agei ng of all structures in city, enhanced escrow instructions, holdbacks in escrow, constant re minder/enforcement of untouched buildings, lender cooperation, insurance industry discounts i.e. CEA 20%, shared city services: trash, permit parking fee waivers, cita tion forgiveness for tenants of in-process retrofit projects, Item 7-A 02/14/17 1 Item 7-A 02/14/17 Adel E. Salawy MD 201 Ocean Avenue, Suite 1609B Santa Monica, CA 90402 February 8, 2017 Dear Honorable Councilmembers, I would like to bring your attention to concerns related to item 7. A. (Updating Seismic Retrofit Re quirements). I have significant concerns regarding the recording of a public notice with the County Recorder which is intended to advise and protect the tenants and public but may have devastating unintended consequences. If the notice copies the example of another city and uses the title "Notice of Substandard Condition" instead of a more general term such as "Notice of Seismic Retrofit Requirement" it may trigger a default of a property owners loan. Additionally, it may make re- financing a property almost impossible thus preventing an owner from obtaining funds needed to retrofit a property. I urge you to consider 1.) not requiring the recordation of a notice on a property; or 2.) modifying the title of the notice to read "Notice of Seismic Retrofit Requirement" or some similar language. This would put the tenants and public on notice and still allow a property owner to refinance a property to obtain funds needed to comply with the retrofit requirements. Housing providers find themselves in this situation through no fault of their own as the buildings were built to the mandated code at the time. We thank you for your consideration. Thank you, Adel E. Salawy, MD Item 7-A 02/14/17 1 Item 7-A 02/14/17 1 Vernice Hankins From:Council Mailbox Sent:Monday, February 13, 2017 10:23 PM To:Ted Winterer; Gleam Davis; Pam OConnor; Sue Himmelrich; Terry O’Day; Kevin McKeown Fwd; Tony Vazquez Cc:councilmtgitems; Elaine Polachek; David Martin Subject:FW: Seismic Retrofit Council ‐    Please  see  the  email  below  re: seismic  retrofit  ordinance.    Thank  you,    Stephanie       From: Mitch  Nahass  [mailto:mitchnahass@hotmail.com]   Sent: Monday, February  13, 2017  4:47  PM   To: Council  Mailbox  <Council.Mailbox@SMGOV.NET>  Subject: Seismic  Retrofit     Dear  Honorable  Councilmembers,    I  would  like  to  bring  your  attention  to  concerns  related  to  item  7. A. (Updating  Seismic  Retrofit  Requirements).    I  have  significant  concerns  regarding  the  recording  of  a  public  notice  with  the  County  Recorder  which   is  in tended  to   advise  and  protect  the  tenant s  and  pu blic  but  may  have  devastating  unintended  consequences.   If  the  notice  copies  the   example  of  another  city  and  uses  the  title  "Notice  of  Substandard  Condition" instead  of  a  more  general  term  such  as   "Notice  of  Seismic  Retrofit  Requirement" it  may  trigger  a  default  of  a  property  own e rs  loan.   Additionally, it  may  make   re ‐financing  a  property  almost  impossible  thus  preventing  an  owner  from  obtaining  funds  needed  to  retrofit  a  property.    I  urge  you  to  consider  1.) not  requiring  the  recordation  of  a  notice  on  a  property; or  2.) modifying  the  title  of  the  notice   to  read  "Notice  of  Seismi c  Retrofit  Requirement" or  some  similar  language.  This  would  put  the  tenants  and  public  on   notice  and  still  allow  a  property  owner  to  refinance  a  property  to  obtain  funds  needed  to  comply  with  the  retrofit   requirements.     Housing  providers  find  themselves  in  this  situation  through  no  fault  of  their  own  as  the  buildings  were  buil t  to  the   mandated  code  at  the  time. We  thank  you  for  your  consideration.    Regards,    Mitch  Nahass   Residential  Property  Owner     Item 7-A 02/14/17 1 Item 7-A 02/14/17 1 Vernice Hankins From:Council Mailbox Sent:Monday, February 13, 2017 10:23 PM To:Ted Winterer; Gleam Davis; Pam OConnor; Sue Himmelrich; Terry O’Day; Kevin McKeown Fwd; Tony Vazquez Cc:councilmtgitems; Elaine Polachek; David Martin Subject:FW: Earthquake Retrofit Council ‐    Please  see  the  email  below  re: seismic  retrofit  ordinance.    Thank  you,    Stephanie       From: Michele  Nasatir  [mailto:mnasatir@gmail.com]   Sent: Monday, February  13, 2017  4:02  PM   To: Council  Mailbox  <Council.Mailbox@SMGOV.NET>  Subject: Earthquake  Retrofit   Dear Honorable Councilmembers, I would like to bring your attention to concerns related to item 7. A. (U pdating Seismic Retrofit Requirements). I have significant concerns regarding the recording of a public notice with the County Recorder which is intended to advise and protect the tenants and public but may have devastating unintended consequences. I f the notice copies the example of another city and uses the title "Notice of Substandard Condition" instead of a more general term such as "Notice of Seismic Retrofit Requirement" it may trigger a default of a property owners loan. Additionally, it may make re-financing a property almost impossible thus preventing an owner from obtaining funds needed to retrofit a property. I urge you to consider 1.) not requiring the recordation of a notice on a property; or 2.) modifying the title of the notice to read "Notice of Seismic Retrofit Requir ement" or some similar language. This would put the tenants and public on notice and still allow a property owner to refinance a property to obtain funds needed to comply with the retrofit requirements. Housing providers find themselves in this situation throug h no fault of their own as the buildings were built to the mandated code at the time. We thank you for your consideration. -- Michele Nasatir 727 San Lorenzo Street Santa Monica, CA 90402 310.459.0213 Item 7-A 02/14/17 1 Item 7-A 02/14/17 1 Vernice Hankins From:Council Mailbox Sent:Monday, February 13, 2017 10:23 PM To:Ted Winterer; Gleam Davis; Pam OConnor; Sue Himmelrich; Terry O’Day; Kevin McKeown Fwd; Tony Vazquez Cc:councilmtgitems; Elaine Polachek; David Martin Subject:FW: Retrofit requirements for apartments Council ‐    Please  see  the  email  below  re: seismic  retrofit  ordinance.    Thank  you,    Stephanie     ‐‐‐‐‐Original  Message ‐‐‐‐‐  From: Johnswafford@swafford.net  [mailto:johnswafford@swafford.net]   Sent: Monday, February  13, 2017  3:25  PM   To: Council  Mailbox  <Council.Mailbox@SMGOV.NET>  Subject: Retrofit  requirements  for  apartments     Dear  Honorable  Council  Members,    I  would  like  to  bring  your  attention  to  concerns  related  to  ite m  7. A. (Updating  Seismic  Retrofit  Require ments).    My  wife  and  I  are  the  retired  owner ‐occupants  of  a  four ‐plex  and  we  have  significant  concerns  regarding  the  recording   of  a  public  notice  with  the  County  Recorder  which   is  intended  to  advise  and  protect  the  tenants  and  public  but  may   have  devastating  uninte nd ed  consequences.   If  the  notice  copies  the  example  of  another  city  and  uses  the  title  "Notice   of  Substandard  Condition" instead  of  a  more  general  term  such  as  "Notice  of  Seismic  Retrofit  Requirement" it  may   trigger  a  default  of  a  property  owners  loan.   Additionally, it  may  make  re ‐financing  a  property  almost  impo ssible  th us   preventing  an  owner  from  obtaining  funds  needed  to  retrofit  a  property.     I  urge  you  to  consider  1.) not  requiring  the  recordation  of  a  notice  on  a  property; or  2.) modifying  the  title  of  the  notice   to  read  "Notice  of  Seismic  Retrofit  Requirement" or  some  similar  language.  This  would  put  the  tenants  and  public  on   notice  and  still  allow  a  pro perty  owner  to  refinance  a  property  to  obtain  funds  needed  to  comply  with  the  retrofit   requirements.     I  take  great  pride  in  my  building  and  in  providing  quality  housing  for  my  tenants  (and  neighbors!). Housing  providers  like   us  find  themselves  in  this  situation  through  no  fault  of  our  own  as  our  buildings  were  built  to  the  mandated  code  at  the   time. We  thank  you  for  your  consideration.    John  Swafford   O: 310 ‐451 ‐0611   M: 310 ‐488 ‐9804   johnswafford@swafford.net     Item 7-A 02/14/17 1 Item 7-A 02/14/17 1 Vernice Hankins From:Council Mailbox Sent:Monday, February 13, 2017 10:24 PM To:Ted Winterer; Gleam Davis; Pam OConnor; Sue Himmelrich; Terry O’Day; Kevin McKeown Fwd; Tony Vazquez Cc:councilmtgitems; Elaine Polachek; David Martin Subject:FW: Earthquake Retrofit notices Council ‐    Please  see  the  email  below  re: seismic  retrofit  ordinance.    Thank  you,    Stephanie       From: Alan  Freedman  [mailto:alanlfreedman@att.net]   Sent: Monday, February  13, 2017  2:28  PM   To: Council  Mailbox  <Council.Mailbox@SMGOV.NET>  Subject: Earthquake  Retrofit  notices   Dear Honorable Councilmembers, I would like to bring your atte ntion to concerns related to item 7. A. (Updating Seismic Retrofit Requirements). I have significant concerns regarding the r ecording of a public notice with the County Recorder which is intended to advise and protect the tenants and public but may have devastating unintended consequences. If th e notice copies the example of another city and uses the title "Notice of Substandard Conditi on" instead of a more general term such as "Notice of Seismic Retrofit Requirement" it may trigger a default of a property owners loan. Additionally, it may make re-financ ing a property almost impossible thus preventing an owner from obtaining funds needed to retrofit a property. I urge you to consider 1.) not requiring the recordation of a notice on a property; or 2.) modifying the title of the noti ce to read "Notice of Seismic Retrofit Requirement" or some similar language. This would put the tenants and public on notice and still allow a property owner to refinance a property to obtain funds needed to comply with the retrofit requirements. Item 7-A 02/14/17 1 Item 7-A 02/14/17 2 Housing and commercial providers find themsel ves in this situation through no fault of their own as the buildings were built to the mandated code at the time. We thank you for your consideration. Alan L. Freedman, longtime resident and property owner in Santa Monica **** I Sent from my iPhone Item 7-A 02/14/17 1 Item 7-A 02/14/17 1 Vernice Hankins From:Council Mailbox Sent:Monday, February 13, 2017 10:25 PM To:Ted Winterer; Gleam Davis; Pam OConnor; Sue Himmelrich; Terry O’Day; Kevin McKeown Fwd; Tony Vazquez Cc:councilmtgitems; Elaine Polachek; David Martin Subject:FW: retrofit Council ‐    Please  see  the  email  below  re: seismic  retrofit  ordinance.    Thank  you,    Stephanie       From: Kelli  [mailto:kellidurode@yahoo.com]   Sent: Monday, February  13, 2017  2:12  PM   To: Council  Mailbox  <Council.Mailbox@SMGOV.NET>  Subject: retrofit   Dear Honorable Councilmembers, I would like to bring your attention to concerns related to item 7. A. (Updating Seismic Retrofit Requirements). I have significant concerns regarding the recording of a public notice with the County Recorder which is intended to advise and protect the tenants and public but may have devastating unintended consequences. If the notice copies the example of another city and uses the title "Notice of Substandard Condition" instead of a more general term such as "Notice of Seismic Retrofit Requirement" it may trigger a default of a property owners loan. Additionally, it may make re-financing a property almost impossible thus preventing an owner from obtaining funds needed to retrofit a property. I urge you to consider 1.) not requiring the recordation of a notice on a property; or 2.) modifying the title of the notice to read "Notice of Seismic Retrofit Requirement" or some similar language. This would put the tenants and public on notice and still allow a property owner to refinance a property to obtain funds needed to comply with the retrofit requirements. Housing providers find themselves in this situation through no fault of their own as the buildings were built to the mandated code at the time. We thank you for your consideration. Item 7-A 02/14/17 1 Item 7-A 02/14/17 1 Vernice Hankins From:pwebs@aol.com Sent:Tuesday, February 14, 2017 8:09 AM To:councilmtgitems Subject:Santa Monica retrofit notifications Dear Council members, I have seen a copy of another city's notification of retrofit to property owners. It is titl ed, "Certificate of Substandard Property". It is my understanding that this would negati vely impact an owner from re-financing and obtaining funds we owners would need to retrofit our proper ties. Please consider an alternate term for "SUBSTANDARD". I applaud Santa Monica's efforts to make our city earthquake safe. Many of us owners have older buildings with tenants that have rented here for 20 or more years. We need to be able to get funding to meet Santa Monica's safety standards. Thank you, Patricia Weber owner 1653 Berkeley Street Santa Monica, CA 90404 Item 7-A 02/14/17 1 Item 7-A 02/14/17 Item 7-A 02/14/17 1 Item 7-A 02/14/17 Item 7-A 02/14/17 1 Item 7-A 02/14/17 Item 7-A 02/14/17 1 Item 7-A 02/14/17 Item 7-A 02/14/17 1 Item 7-A 02/14/17 1 Vernice Hankins From:Carol Lemlein <lemlein@aol.com> Sent:Tuesday, February 14, 2017 12:47 PM To:councilmtgitems Cc:David Martin; Jing Yeo; Ron Takiguchi Subject:Seismic Safety Ordinance, City Council Agenda Item 7A, February 14, 2017 Mayor Winterer, Mayor Pro Tempor e Davis, and Councilmembers: The Santa Monica Conservancy wishes to ca ll your attention to the omission of consideration of historic resources in the st aff report and the ordinance. The February 13 th Los Angeles Times article on this issue featured a photograph of the Keller Block as an example of unreinforced masonry; this bu ilding is designated as a Santa Monica Landmark and is an important feature of our downtown. While we completely support the objective of public safety in moving forward with structural repairs to existing buildings on th e City’s list, as well as the emphasis on tenant protections, the impacts of the specif ied timetable and the failure to consider the unique needs and circumstances of our hi storic resources co uld have negative consequences. We respectfully ask that st aff be requested to incorporate specific provisions for historic resources. These issues exist for all historic structures, but are most visible at the extreme ends of the proposed timetable. We suggest that st aff annotate the City’s list of hazardous buildings to identify those which are design ated landmarks, structures of merit, or Historic Resource Inventory (HRI) properties. We note numerous unreinforced masonry buildings on Main Street – for example – that have lo ng been thought of as a noteworthy historic streetscape. These desi g nated historic resources and HRI properties may require a longer or more flexible compliance timeta ble, upon request by the owner. Just as historic resources are give n flexibility in the zoning code concerning development standards, parking requiremen ts, and similar issues to support their continued economic viability, compliance with structural upgrades warrants special consideration so that we do not lose our irreplaceable historic resources. At the other end of the timeta ble, we are very concerned ab out those historic resources identified as non-ductile concrete buildings, particularly those which stand vacant and where City action – or la ck thereof - is impedin g rehabilitation that would include seismic upgrades. The Civic Auditorium, despite efforts of a dedicated Working Group, languishes in limbo. The Sears Building, soon to be vacant, has an adaptive reuse proposal pending that is delayed until the Downtown Plan and the Gateway Plan have been adopted. These important buildings are at risk of major seismic damage until they can be rehabilitated. While the staff report refers to recent state legislation that could provide funding access for owners in the form of a loan fund, we also recomme nd that possible sources of financial support for historic resources, pa rticularly designated landmarks, be further Item 7-A 02/14/17 1 Item 7-A 02/14/17 2 investigated. It should be emphasized that historic resources are permitted to utilize the State Historical Buildin g Code (SHBC), which has re g ulations pertainin g to seismic safety and may provide alternative me ans and methods which reduce costs. Use of the SHBC in Santa Monica has often been a very diffic ult, time-consuming an d therefore expensive process for property owners, and priority processing of such requests should be required. In conclusion, please consider the following actions in moving forward with the seismic safety ordinance:  Identify those properties that qualify as historic resources as landmarks or structures of merit, or which are li sted on the City’s HRI;  Specify that those properties are eligible to use the State Historical Building Code;  Consider additional sources of funding that may be availa ble for historic resources;  Adopt a more flexible timetable for complianc e for the City’s historic resources; and finally  Proactively consider other ac tions which will encourage, rather than impede, retrofit of our important vacant or soon to be vacant landmark buildings. Thank you! Carol Lemlein President, Santa Monica Cons ervancy Board of Directors www.smconservancy.org Item 7-A 02/14/17 1 Item 7-A 02/14/17 1 Vernice Hankins From:Council Mailbox Sent:Tuesday, February 14, 2017 3:49 PM To:Ted Winterer; Gleam Davis; Pam OConnor; Sue Himmelrich; Terry O’Day; Kevin McKeown Fwd; Tony Vazquez Cc:councilmtgitems; Elaine Polachek; David Martin Subject:FW: Seismic Retrofit Ordinance Revisions - Boularan Godard Partnership - Santa Monica Council ‐    Please  see  the  email  below  re: seismic  retrofit  ordinance.    Thank  you,    Stephanie     From: Alan  Alain  [mailto:alanalain@gmail.com]   Sent: Tuesday, February  14, 2017  2:50  PM   To: Council  Mailbox  <Council.Mailbox@SMGOV.NET>; Bill  Dawson  <bdawson@linkline.com>  Subject: Seismic  Retrofit  Ordinance  Revisions  ‐ Boularan  Godard  Partnership  ‐ Santa  Monica   Dear Honorable Council members, I would like to bring your attention to concerns related to item 7. A. (Updating Seismic Retrofit Requirements). I have significant concerns regarding the recording of a public notice with the County Recorder which is intended to advise and protect the tenants and public, but may have devastating unintended consequences. If the notice copies the example of another city and uses the title "Notice of Substandard Condition" instead of a more general term such as "Notice of Seismic Retrofit Requirement" it may trigger a default of a property owners loan. Additionally, it may make re-financing a property almost impossible thus preventing an owner from obtaining funds needed to retrofit a property. I urge you to consider 1.) not requiring the recordation of a notice on a property; or 2.) modifying the title of the notice to read "Notice of Seismic Retrofit Requirement" or some similar language. Item 7-A 02/14/17 1 Item 7-A 02/14/17 2 This would put the tenants and public on notice and still allow a property owner to refinance a property to obtain funds needed to comply with the retrofit requirements. Housing providers find themselves in this situation through no fault of their own as the buildings were built to the mandated code at the time. I thank you for your consideration of this important matter.. Boularan Godard Family Partnership AOA - AAGLA member - Santa Monica Rental Property owner Alain Boularan - Gal. Partner 1252, 24th Street - Ste.1 Santa Monica, Ca - 90404 Tel. : (310) 453 3561 (310) 403 6410 Item 7-A 02/14/17 1 Item 7-A 02/14/17 Board Members, Cont. Jeff Jarow PAR Commercial Real Estate Brokerage Jeff Klocke Pacific Park on the Santa Monica Pi er Mitchell Kraus Capital Intelligence Associates Tim Kusserow Carlthorp School Leonard “Len” Lanzi Los Angeles Venture Association Paula Larmore Harding Larmore Kutcher & Kozal, LLP Jeff Lasky Hudson Pacific Properties, Inc. Matt Lavin Worthe Real Estate Group Richard Lawrence Commercial Bank of California Paul Leclerc Le Meridien Delfina Gary Loeb Chezgal Merchandising Creations Marcel Loh St John’s Health Center Providence Brian Mac Mahon Expert Dojo Ellis O’Connor MSD Hospitality Fai rmont M iramar Hotel & Bungalows Susan Gabriel Potter Bob Gabriel Insurance Nat Trives Coalition for Engaged Educations Juan Viramontes Georgian Hotel John Warfel Metropolitan Pacific Adam Weiss Cornerstone OnDemand, Inc. Chair Yesenia Monsour Kaiser Permanente Chair Elect West Hooker Locanda del Lago Past C hair Julia Ladd Santa Monica Place Chief Financial Of ficer Dave Nelson Tegner -Miller Insurance Brokers Vice Chairman Barbara Bishop BBPR, Inc. Vice Chairman Richard Chacker Perry’s Café and Bike Rentals Vice Chairman Justin Grant Morley Builders Vice Chairman Pat McRoskey Water Garden Vice Chairman Sc ott Schonfeld Linwood Ventures Board Members Daniel Abramson RAND Corporation Matthew Allnatt Jonathan Club Alisha Auringer L A carGuy Ted Braun UCLA Health Julia Cooksey Frontier Communications Kiersten Elliott Santa Monica College Michael Grunin g Pence Hawthorn Colby Goff Rustic Canyon Family Mike Harriel Southern California Gas Company Susan Inwood Wells Fargo Advisors, LLC February 14 , 2017 Santa Monica City Council 1685 Main Street, Room 102 Santa Monica, CA 90401 Re: Item #7 A - Seismic Retrofit Program Draft Ordinance Dear Mayor Winterer and Councilmembers : The Chamber strongly support s the proposed Seismic Retrofit Program Ordinance. Our businesses, residents, and visitors deserve a safe Santa Monica , and we commend the C ity for making this a priority. We do, however, have a few recommendations regarding the implementation and timing of the requirements . Several of our members , who own and/or occupy buildings on the Potentially Vulnerable Buildings list have reached out to us with their concerns. Below are three areas that we believe should be a ddressed to ensur e that the ordinance will not be unnecessarily burd ensome : 1. Timing a. While the city reviews the structural report , the time limit clock for submitting the building permit and completing the retrofit should be paused . b. If a retrofit is deemed necessary, the clock should again pause while the City reviews the retrofit plans. c. If a retrofit includes exterior modificatio n s that would require design rev iew, more time should be allowed. 2. Parking Reduction s The allowable loss of parking resulting from a retrofit should not be limited to a specific percentage or number . Staff should be granted more discretion in approving parking reduction s . Chair Yesenia Monsour Kaiser Permanente Chair Elect West Hooker Locanda del Lago Past C hair Julia Ladd Santa Monica Place Chief Financial Of ficer Dave Nelson Tegner -Miller Insurance Brokers Vice Chairman Barbara Bishop BBPR, Inc. Vice Chairman Richard Chacker Perry’s Café and Bike Rentals Vice Chairman Justin Grant Morley Builders Vice Chairman Pat McRoskey Water Garden Vice Chairman Sc ott Schonfeld Linwood Ventures Board Members Daniel Abramson RAND Corporation Matthew Allnatt Jonathan Club Alisha Auringer L A carGuy Ted Braun UCLA Health Julia Cooksey Frontier Communications Kiersten Elliott Santa Monica College Michael Grunin g Pence Hawthorn Colby Goff Rustic Canyon Family Mike Harriel Southern California Gas Company Susan Inwood Wells Fargo Advisors, LLC Board Members, Cont. Jeff Jarow PAR Commercial Real Estate Brokerage Jeff Klocke Pacific Park on the Santa Monica Pi er Mitchell Kraus Capital Intelligence Associates Tim Kusserow Carlthorp School Leonard “Len” Lanzi Los Angeles Venture Association Paula Larmore Harding Larmore Kutcher & Kozal, LLP Jeff Lasky Hudson Pacific Properties, Inc. Matt Lavin Worthe Real Estate Group Richard Lawrence Commercial Bank of California Paul Leclerc Le Meridien Delfina Gary Loeb Chezgal Merchandising Creations Marcel Loh St John’s Health Center Providence Brian Mac Mahon Expert Dojo Ellis O’Connor MSD Hospitality Fai rmont M iramar Hotel & Bungalows Susan Gabriel Potter Bob Gabriel Insurance Nat Trives Coalition for Engaged Educations Juan Viramontes Georgian Hotel John Warfel Metropolitan Pacific Adam Weiss Cornerstone OnDemand, Inc. 3. O t he r Compliance Issues The ordinance should clearly state that retrofitting will not trigger other unrelated compliance issues, like the new Resource Recovery an d Recycling Standards. Property owners should n o t be simultaneously saddled with complying with an unrelated and expensive standard . E arthq uake safety is t he priority and other issues should n o t be triggered by a mandatory retrofit. Again, we support this ordinance as an important and necessary step in ensuring our communit y ’s safety and resilience in the event of an earthquake . We hope that you will consider our comments and those of other property owners and tenants that have contacted you, in developing what we hope will be a model ordinance for Santa Monica. Sincerely, Yesenia M onsour Laurel Rosen Chair President / CEO 1 F EBRUAR Y 14, 2017 C ITY OF S ANT A M ONICA S EISMIC R ETROFIT P ROGRAM & T ENANT P ROTECTIONS 2 3 S EISMIC R ETR OFIT P ROGRAM •Council Study Session; December 6, 2016 •Updat e T echnical St andards & Develop Ordinance •Seismic R etrofit Program S EISMIC R ETROFIT P ROGRAM 4 M AND AT OR Y SEISMIC RETROFIT RE QUIREMENTS Chapter 8.58 ADMINISTRA TIVE NEW Chapter 8.60 UNREINFORCED MASONRY BEARING W ALL BUILDINGS Chapter 8.64 CONCRETE AND REINFORCED MASONRY WA LL BUILDINGS WITH FLEXIBLE DIAPHRAGMS Chapter 8.68 VOL UNT ARY CRIPPLE WA LLS AND SILL PLA TE ANCHORAGE IN SINGLE -FA MIL Y DWELLINGS Chapter 8.72 SOFT , WEAK OR OPEN FRONT WA LLS IN LIGHT , WOOD -FRAMED BUILDINGS Chapter 8.76 WELDED STEEL MOMENT FRAME STRUCTURES Chapter 8.80 NON -DUCTILE CONCRETE BUILDINGS A RTICLE VIII –S ANT A M ONICA M UNICIP AL C ODE S EISMIC R ETROFIT C HAPTER S S EISMIC R ETROFIT P ROGRAM 5 S EISMIC R ETR OFIT P ROGRAM •Or dinance -Pr ogr am Elemen ts •Ext ension Time Limits: Good Cause, PCD Direct or •Pa rking –Tr ash Enclosures –Cons truction Rat e Program •CE QA Ex emption •St affing FY 17 -19 Budget •Consulting Ser vices –Plan R eview , P eer R eview •Te nant Protections: Chapter 4.36 -&-Chapter 8.100 S EISMIC R ETROFIT P ROGRAM 6 S EISMIC R ETR OFIT P ROGRAM •Or dinance Does Not Include: •Ex emptions t o CA Coas ta l Commission Where Applicable •Ex cept Minor W ork, Interior W ork •Ex emptions St at e Ac cessibility R equiremen ts •Ex cept Existing Multi -Fa mily Dwellings March 13, 1991 •Re nt Control Board P ass -Through Cos ts •Board Hearing F ollowing Council 2 nd Re ading S EISMIC R ETROFIT P ROGRAM 7 S EISMIC R ETR OFIT P ROGRAM •Or dinance R evision: •Re move 8.58.130 R ec ordation S EISMIC R ETROFIT P ROGRAM 8 9 htt p://www .smgov .net/Departmen ts/PCD/Pr ogr ams/Seismic -Re tr ofit / 10 S EISMIC R ETR OFIT P ROGRAM S EISMIC R ETROFIT P ROGRAM 11 S EISMIC R ETR OFIT P ROGRAM •Lis t = 2,054 Iden tified Buildings •Landmark Structures =31 •His to ric R esources In ventor y = 229 (44 “Code 6 or 7”)= 185 •Mills Act = 5 •Structures of Merit = 0 S EISMIC R ETROFIT P ROGRAM 12 S EISMIC R ETR OFIT P ROGRAM •Community / St ak eholder Outr each •Commercial -Business: SM Chamber , D TSM, BOMA •Re siden t Building Owners: A CTION, AA GLA •Re siden ts: SMRR •Building And Fire -Lif e Saf ety Commission •Council Study Session S EISMIC R ETROFIT P ROGRAM 13 C HAPTER 8.100 T ENANT P RO TE CTION Updates –Str eng thened Measur es •(8.58.070 T enan t and Oc cupant Advisory) •Te nan t Noticing R equir emen ts –Add Af fe ct ed T enan ts •Or der by Building Of ficer , Pr ogr ess Meeting –Add Not Appealable S EISMIC R ETROFIT P ROGRAM 14 C HAPTER 8.100 T ENANT P RO TE CTION Updates –Str eng thened Measur es •New 8.100.080 Haz ar dous Materials •Pr oper Handling, Pr oof to Building Officer •Haz ar dous Materials Consultant –Owner Expense S EISMIC R ETROFIT P ROGRAM 15 C HAPTER 4.36 T ENANT R EL OCA TION S EISMIC R ETROFIT P ROGRAM Updates –Str eng thened Measur es •Re location Less Than 30 Da ys •Option: •Re location Costs P er Diem •Compar able Housing •Add Hotel or Motel if R elocation 5 Da ys or Less •Add If Ext ends Mor e Than 5 Da ys P er Diem, Compar able Housing, or Hot el if T enan t Agr ees 16 C HAPTER 4.36 T ENANT R EL OCA TION S EISMIC R ETROFIT P ROGRAM Updates –Str eng thened Measur es •Clarify No R elocation Benefits to T enan t if elects t o r emain •Add Clarification Re location Benefits not aff ect limit ed access 17 C HAPTER 4.36 T ENANT R EL OCA TION S EISMIC R ETROFIT P ROGRAM Updates –Str eng thened Measur es •New Re location does not e xc eed es timated period by Building Officer -or -ex te nsion f or good cause •New Pr ompt action by owner •Delete Ex emption to R elocation Benefits due to Seismic R etr ofit URM (152) Concrete Tilt -Up (31) Soft Story -3 and 4 Stories (~400) Soft Story -16 or More Units (~60) Soft Story –2 Story , 7 to 15 Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Non -Ductile Concret e (64) Steel Moment Frame (79) 2 Y EARS 3 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 20 Y EARS 10 Y EARS URM (152) Concrete Tilt -Up (31) Soft Story -3 and 4 Stories (~400) Soft Story -16 or More Units (~60) Soft Story –2 Story , 7 to 15 Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Non -Ductile Concret e (64) Steel Moment Frame (79) 2 Y EARS 3 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 20 Y EARS 10 Y EARS Notices Sent URM (152) Concrete Tilt -Up (31) Soft Story -3 and 4 Stories (~400) Soft Story -16 or More Units (~60) Soft Story –2 Story , 7 to 15 Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Non -Ductile Concret e (64) Steel Moment Frame (79) 2 Y EARS 3 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 20 Y EARS 10 Y EARS Notices Sent Eva luation R eport URM (152) Concrete Tilt -Up (31) Soft Story -3 and 4 Stories (~400) Soft Story -16 or More Units (~60) Soft Story –2 Story , 7 to 15 Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Soft Story –2 Story , 6 or Less Units (~300) Non -Ductile Concret e (64) Steel Moment Frame (79) 2 Y EARS 3 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 6 Y EARS 20 Y EARS 10 Y EARS Notices Sent Eva luation R eport Staff Peak Demand 22 S EISMIC R ETR OFIT P ROGRAM •Pr ocess –Implemen tation •Con tinued Community / St ak eholder Meetings •Te chnical Assist ance Guides to Seismic R etrofit •Seismic R etrofit F air •Aff ect ed Departmen ts –Plan R eview & Pe rmit ting •Fu ll W eb P age R esource S EISMIC R ETROFIT P ROGRAM 23 Council R ec ommended t o: 1.Adopt R esolution of Local Building Code Amendments based on Local Conditions 2.Adopt Ordinances: •Updating T echnical St andards f or Seismic R etrofit of Haz ardous Buildings •Re visions t o T enan t Prot ection During Cons truction •Re visions t o T enan t R elocation Provisions 3.Instruct St aff t o File Local Amendments with CA Bldg St ds Commission S EISMIC R ETROFIT P ROGRAM Reference:       Resolution  No. 11022   (CCS)