November 14, 1977
TO: Mayor and City Council
FRm~: Ci ty Staff
SUBJECT: Recommendations for Changes in Refuse Collectlon Ordinance
Introduction
This report recommends that the Refuse Collection Ordinance be modified
to provide that owners of multiple residential unit buildings with SlX
units or more be required to have bin container service. It also
recommends changes which will require that a discharge shutoff system
be installed in all bUlldings with refuse chutes.
Background
At the present time, the City offers refuse service to multiple residential
units, and it is the option of the property owner whether or not they wish
to provide thelr own containers (garbage cans) or if they wish to rent
larger bin containers from the City. For duplexes and residential units
up to approximately $lX units, cans are a satisfactory method of containing
the refuse while it awaits collection. For larger residential complexes,
the number of cans becomes so large that it is inefficient for the City
and unsightly to residents for the property owner to use cans as opposed
to bins. Therefore, it is proposed to establish a limlt on the number of
units where property owners may use cans for refuse and to reaUlre that
the owners subscrlbe for bin service if the number of units is In excess
of this limit. This proposed change will affect approximately 500
residential units (about 70-80 customers). The increased cost to the
110
NOV 2 2 1977
.
703-00~03.
-2-
November 14. 1977
To: Mayor and City Council
owner of a typical 6 - 10 unit building will be the bln rental charge
($4.00 per month for a two-cubic-yard bin).
Many multiple residential and office buildlngs have been and are being
designed with refuse collection chutes. Some of these systems have a
shutoff gate at the bottom which can be closed by the refuse workers when
they come to empty the bin. On the buildings WhlCh do not have these
shutoff gates. the refuse frequently backs up in the chute and falls on
the floor when the bin is removed for emptying. creating a great deal
of extra unnecessary work to clean up the refuse.
There are several manufacturers of these gates and the installed costs for
them dre from $250 to $700 as shown on the attached sheet.
This problem only exists for the Clty when there is on-site refuse
collection. Therefore. it is recommended that such systems be made a
condition of on-site collection by the City.- If the owners of the buildlng
wish to take the responsibility for pushing the bin out to the alley, there
would be no changes required.
Recommendation
It is recommended that the City Attorney be instructed to prepare modifications
in the Refuse Ordinance to require that bins be required for residentlal com-
plexes with six units or more and to require dlscharge shutoff systems for
all new buildings with refuse chutes and for all existing buildings with
chutes within the next six months, as a condition of on-site refuse service.
Prepared by: S. E. Scholl
SES'cs
5.t7 3- ~o/-o3 .
DIRECT DISCHARGE
.
discharge openings
HOPPER DISCHARGE
. . .
TYPE "H" TOP HINGED
TYPE "H" SIDE HINGED
~
I j'
Ii
fl
J
;
E' "
"O'D....
F' $TO. I
r smJ
) *'~'
;l
I
r~
II
l~
f
, . ADJU5TA8L!
~ w....u. "~CHORS
" 2.x fi-
I'. I
rdJ
1/
ILl,,'
~ I
l'-J;,
r:'rl
I ....0
!=~~I
:~a::co
~a: i::E
OI~~O
:::;Io.~~ -45-
U a:...w
ol-~
:1,;,,1%0::
:;n=,~
!~g;;
.uoC~
f-
! rn
; f Il- SUPVO~mOESTAL
j MOlt .ll.
r 0 ~l.. ~" U. '-""" j& OC-....-"I"O-.:!'t~ ~~-It.I SoT'.... \..L"'O' - -
D' 01"-
.J
j
1
A I dp&l\ll~G
....
SIZE A B C D E f' G H J
12 x 24 12Yi 24lir 3H~ 12' 6% 14 2ni 5 15*
15 x 24 ISlir 24'4 34* 15 8* mol, 2H~ s 18*
l!h 3D 18Yi 3O'k 40% 18 9* It 33% a mil
2DdD lD"" 3ll~ ~ 20 ID!4 18 33* ~ 23%
24 x ]0- Z4~ 30Y. 401.5 24 12* 2Q 33li 12, 27%
28 x 3& 28~ 351-i 46* 28 14% 22 39% g. 31"'i
36 x 48 36\-3 48~'o Sill.'. 3& 18~ 26 51* IS" 39Yr
'Coun\erbala~c8 o.i-both SIdes of door...
t;).O" O....L."\" _Y-3-~O':TQ 4g0 l.....trT~\..&. CoP
The Type "F1" hDpper discharge IS used when some material IS to be ~tDred
In the chute or when the discharge IS to be bUilt mto wall The hopper IS normally
bUIlt from the sa'l1e material as the chute The dIscharge operung IS formed onto
a slructural angle door frame The sloped bottom IS remforced and IS supported
on a 2" pipe pedeslal When the matenal dropp~d IS e~ceptlonally heavy orwhen
the Ile:<lht cf drop IS great, the Impact plate thickness can be Increased and a
structural steel support frame substituted for the pipe pedestal A 2" drain at
the low pomt of the hopper permits f1ushmg down the chute with the door dosed
The discharge door IS usually furnished top lllnged, but It can also be furnished
Side Ilmged Either IS a~allable WIth U l , lI'c Class "B" label The top hmged
door has a Spfl'1g counterbalance that holdst!;e door open unless closed manually
The counterbalance "as a fUSible hnk that permits the door to automatlc~l[y s'1ut
In case the link IS fused The Side hinged door has spnng loaded hinges that close
the door when It IS released Both types have a lever latch at the bottom to draw
the door tight against the gasket when the chute IS being flushed down
^,?Q \T Ie.... "-L CIotUT€' .. 'Z.~ / t:"OOT
Jf
l.L
,.
~ .
>(!
_7'
11'
I
I- E"--j
;.,
SIZE A a c D E F G H
36 3& 37 39~ 11 19* 38 II'" Jll:",
3D 3D 31 J3\oi 65 16Yi 32 IOV. 1',1,
2a 2a 29 31!.i 6l'h 15% 30 10;, 11',,,,
24 24 25 27\1, 53'~ 13Yi 20 10'~1 2'^
20 20 21 23~ 45Yi m~ Z2 gYo 2~",
18 18 19 21'h 41'1. lDYi 2D 9Vz ~i"
15 15 16 18'4 35',i 8* 17 9% 21"
,,.
12 12 13 15\oi 29Vo 7% 14 9 3"
/1
PLAN TYPE "00"
D
30'1-
25'i.
22J4-
201~-
The Type "A" honzOf1tal roiling door IS used for rubbish chute mstall~tIOll3
on any chute With Dpen end discharge The door IS of "B" lallel constructlO'1 mt!'J
1" thick insulation enclosed In an alumllllzed ~teel cover, but It does not bear a
label. The door IS supported by four rollers f1cllnj In Inclined tracks and lS he:d
normally open With a fuSible lmk. Wherr tt,e lmk IS fused by e~ce3Slve heat,
gravity causes the door to roll shut
The Type "00" flap door IS also used for a'1, cpen end discharge rubbish chute
The door IS of "8" I3bel CO'1structlon With 1" thick lI'sulallon encllJsed In an
aluminized steel cover, but :t does not bear a label illS continuous I, hlRg~d D1
one Side, and IS held Dpel' With a fUSible hnk A spring loaded closH::; mechamsm
closes the door when the link IS fused
A Type "0" discharge plain Dpen end 'Nit;, no door ;s sometimes used on
small chufes
NOH I' When uSing eIther the "A", "00" or"O" type cf dlsc~arge, collect:o"
room shGuld be relatl'lely airtight, preferably kept at a negative pressure to